Yoshinori Kanno

Yoshinori Kanno

Auto-generated profile, based on publicly available information

Yoshinori Kanno

Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2009 in Surface and Coatings Technology
Verified
Journal Article
Closed access
KNKikuo Nakano
Kikuo Nakano
NFNorihiko Fukatsu
Norihiko Fukatsu
YKYoshinori Kanno
Yoshinori Kanno

23 January 2020 in Open Heart
Verified
Journal Article
Open access
PDF file
YKYoshinori Kanno
Yoshinori Kanno
MHMasahiro Hoshino
Masahiro Hoshino
RHRikuta Hamaya
Rikuta Hamaya
TSTomoyo Sugiyama
Tomoyo Sugiyama
YKYoshihisa Kanaji
Yoshihisa Kanaji
TKTsunekazu Kakuta
Tsunekazu Kakuta
Background Measurement of the contrast-flow quantitative flow ratio (cQFR) is a novel method for rapid computational estimation of fractional flow reserve (FFR). Discordance between FFR and cQFR has not been completely characterised. Methods We performed a post-hoc analysis of 504 vessels with angiographically intermediate stenosis in 504 patients who underwent measurement of FFR, coronary flow reserve (CFR), the index of microcirculatory resistance (IMR) and Duke jeopardy score. Results In total, 396 (78.6%) and 108 (21.4%) lesions showed concordant and discordant FFR and cQFR functional classifications, respectively. Among lesions with a reduced FFR (FFR+), those with a preserved cQFR (cQFR−) showed significantly lower IMR, shorter mean transit time (Tmn), shorter lesion length (all, p<0.01) and similar CFR and Duke jeopardy scores compared with lesions showing a reduced cQFR (cQFR+). Furthermore, lesions with FFR+ and cQFR− had significantly lower IMR and shorter Tmn compared with lesions showing a preserved FFR (FFR−) and cQFR+. Of note, in cQFR+ lesions, higher IMR lesions were associated with decreased diagnostic accuracy (high-IMR; 63.0% and low-IMR; 75.8%, p<0.01). In contrast, in cQFR− lesions, lower IMR lesions was associated with decreased diagnostic accuracy (high-IMR group; 96.8% and low-IMR group; 80.0%, p0.80) and a cQFR below the lower limit (≤0.75). In contrast, five territories (1.0%; ‘jump in’ group) exhibited opposite results (FFR of ≤0.75 and cQFR of >0.80). The ‘jump out’ territories showed significantly higher IMR values than ‘jump in’ territories (p<0.01). Conclusions FFR− with cQFR+ is associated with increased microvascular resistance, and FFR+ with cQFR− showed preservation of microvascular function with high coronary flow. Microvascular function affected diagnostic performance of cQFR in relation to functional stenosis significance.

15 November 2020 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
TSTomoyo Sugiyama
Tomoyo Sugiyama
YKYoshinori Kanno
Yoshinori Kanno
RHRikuta Hamaya
Rikuta Hamaya
YKYoshihisa Kanaji
Yoshihisa Kanaji
MHMasahiro Hoshino
Masahiro Hoshino
TKTsunekazu Kakuta
Tsunekazu Kakuta

9 November 2019 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
MYMasao Yamaguchi
Masao Yamaguchi
TYTaishi Yonetsu
Taishi Yonetsu
MHMasahiro Hoshino
Masahiro Hoshino
TSTomoyo Sugiyama
Tomoyo Sugiyama
YKYoshihisa Kanaji
Yoshihisa Kanaji
TKTsunekazu Kakuta
Tsunekazu Kakuta

3 February 2020 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
YKYoshinori Kanno
Yoshinori Kanno
TSTomoyo Sugiyama
Tomoyo Sugiyama
MHMasahiro Hoshino
Masahiro Hoshino
EUEisuke Usui
Eisuke Usui
RHRikuta Hamaya
Rikuta Hamaya
TKTsunekazu Kakuta
Tsunekazu Kakuta