Jeong-Hoon Oh

Jeong-Hoon Oh

Auto-generated profile, based on publicly available information

Jeong-Hoon Oh

Department of Otorhinolaryngology-Head and Neck Surgery, College of Medicine, The Catholic University of Korea, Seoul, Korea

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Gait & Posture
Verified
Journal Article
Closed access
Moataz EltoukhyMoataz Eltoukhy
Moataz Eltoukhy
JOJeonghoon Oh
Jeonghoon Oh
CKChristopher Kuenze
Christopher Kuenze
JSJoseph Signorile
Joseph Signorile

10 April 2017 in Medical Engineering & Physics
Verified
Journal Article
Closed access
MEMoataz Eltoukhy
Moataz Eltoukhy
CKChristopher Kuenze
Christopher Kuenze
JOJeonghoon Oh
Jeonghoon Oh
MJMarco Jacopetti
Marco Jacopetti
SWSavannah Wooten
Savannah Wooten
JSJoseph Signorile
Joseph Signorile
Gait patterns differ between healthy elders and those with Parkinson's disease (PD). A simple, low-cost clinical tool that can evaluate kinematic differences between these populations would be invaluable diagnostically; since gait analysis in a clinical setting is impractical due to cost and technical expertise. This study investigated the between group differences between the Kinect and a 3D movement analysis system (BTS) and reported validity and reliability of the Kinect v2 sensor for gait analysis. Nineteen subjects participated, eleven without (C) and eight with PD (PD). Outcome measures included spatiotemporal parameters and kinematics. Ankle range of motion for C was significantly less during ankle swing compared to PD (p=0.04) for the Kinect. Both systems showed significant differences for stride length (BTS (C 1.24±0.16, PD=1.01±0.17, p=0.009), Kinect (C=1.24±0.17, PD=1.00±0.18, p=0.009)), gait velocity (BTS (C=1.06±0.14, PD=0.83±0.15, p=0.01), Kinect (C=1.06±0.15, PD=0.83±0.16, p=0.01)), and swing velocity (BTS (C=2.50±0.27, PD=2.12±0.36, p=0.02), Kinect (C=2.32±0.25, PD=1.95±0.31, p=0.01)) between groups. Agreement (RangeICC =0.93-0.99) and consistency (RangeICC =0.94-0.99) were excellent between systems for stride length, stance duration, swing duration, gait velocity, and swing velocity. The Kinect v2 can was sensitive enough to detect between group differences and consistently produced results similar to the BTS system.

26 October 2017 in Medical Engineering & Physics
Verified
Journal Article
Closed access
MEMoataz Eltoukhy
Moataz Eltoukhy
CKChristopher Kuenze
Christopher Kuenze
MAMichael S. Andersen
Michael S. Andersen
JOJeonghoon Oh
Jeonghoon Oh
JSJoseph Signorile
Joseph Signorile
Kinetic gait abnormalities result in reduced mobility among individuals with Parkinson's disease (PD). Currently, the assessment of gait kinetics can only be achieved using costly force plates, which makes it difficult to implement in most clinical settings. The Microsoft Kinect v2 has been shown to be a feasible clinic-based alternative to more sophisticated three-dimensional motion analysis systems in producing acceptable spatiotemporal and kinematic gait parameters. In this study, we aimed to validate a Kinect-driven musculoskeletal model using the AnyBody modeling system to predict three-dimensional ground reaction forces (GRFs) during gait in patients with PD. Nine patients with PD performed over-ground walking trials as their kinematics and ground reaction forces were measured using a Kinect v2 and force plates, respectively. Kinect v2 model-based and force-plate measured peak vertical and horizontal ground reaction forces and impulses produced during the braking and propulsive phases of the gait cycle were compared. Additionally, comparison of ensemble curves and associated 90% confidence intervals (CI90) of the three-dimensional GRFs were constructed to investigate if the Kinect sensor could provide consistent and accurate GRF predictions throughout the gait cycle. Results showed that the Kinect v2 sensor has the potential to be an effective clinical assessment tool for predicting GRFs produced during gait for patients with PD. However, the observed findings should be replicated and model reliability established prior to integration into the clinical setting.

1 October 2017 in Gait & Posture
Verified
Journal Article
Closed access
MEMoataz Eltoukhy
Moataz Eltoukhy
CKChristopher Kuenze
Christopher Kuenze
JOJeonghoon Oh
Jeonghoon Oh
SWSavannah Wooten
Savannah Wooten
JSJoseph Signorile
Joseph Signorile

22 March 2017 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
MEMoataz A. Eltoukhy
Moataz A. Eltoukhy
CKChristopher Kuenze
Christopher Kuenze
JOJeonghoon Oh
Jeonghoon Oh
JSJoseph F. Signorile
Joseph F. Signorile
Reduction in balance is an indicator of fall risk, and therefore, an accurate and cost effective balance assessment tool is essential for prescribing effective postural control strategies. This study established the validity of the Kinect v2 sensor in assessing center of mass (CoM) excursion and velocity during single leg balance and voluntary ankle sway tasks among young and elderly subjects. We compared balance outcome measures (anteroposterior (AP) and mediolateral (ML) CoM excursion and velocity and average sway length) to a traditional three-dimensional motion analysis system. Twenty subjects (10 young: age = 20.5±2.3 y, height = 171.8±7.2 cm, weight = 70.7±11.6 kg; 10 elderly: age = 70.6±9.5 y, height = 169.1±8.7 cm, weight = 74.0±17.8 kg), with no history of lower extremity injury, participated in this study. Subjects performed six randomized trials; four single leg stand (SLS) and two ankle sway trials. SLS and voluntary ankle sway trials showed that consistency (ICC(2,k)) and agreement (ICC(3,k)) for all variables when all subjects were considered, as well as when the elderly and young groups were analyzed separately. Concordance between systems ranged from poor to nearly perfect depending on the group, task, and variable assessed.

31 August 2022 in iScience
Verified
Journal Article
Open access
JOJeonghoon Oh
Jeonghoon Oh
ASAlexander G. Steele
Alexander G. Steele
BVBlesson Varghese
Blesson Varghese
CMCatherine A. Martin
Catherine A. Martin
MSMichelle S. Scheffler
Michelle S. Scheffler
DSDimitry G. Sayenko
Dimitry G. Sayenko
Transcutaneous spinal stimulation (TSS) is a promising approach to restore upperlimb (UL) functions after spinal cord injury (SCI) in humans. We sought to demonstrate the selectivity of recruitment of individual UL motor pools during cervical TSS using different electrode placements. We demonstrated that TSS delivered over the rostrocaudal and mediolateral axes of the cervical spine resulted in a preferential activation of proximal, distal, and ipsilateral UL muscles. This was revealed by changes in motor threshold intensity, maximum amplitude, and the amount of post-activation depression of the evoked responses. We propose that an arrangement of electrodes targeting specific UL motor pools may result in superior efficacy, restoring more diverse motor activities after neurological injuries and disorders, including severe SCI.