Joseph F. Signorile

Joseph F. Signorile

Auto-generated profile, based on publicly available information

Joseph F. Signorile

University of Miami

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Gait & Posture
Verified
Journal Article
Closed access
Moataz EltoukhyMoataz Eltoukhy
Moataz Eltoukhy
JOJeonghoon Oh
Jeonghoon Oh
CKChristopher Kuenze
Christopher Kuenze
JSJoseph Signorile
Joseph Signorile

1 December 2014 in Experimental Gerontology
Verified
Journal Article
Closed access
ABAnoop Balachandran
Anoop Balachandran
SKSteven N. Krawczyk
Steven N. Krawczyk
MPMelanie Potiaumpai
Melanie Potiaumpai
JSJoseph F. Signorile
Joseph F. Signorile

1 March 2016 in Archives of Physical Medicine and Rehabilitation
Verified
Journal Article
Closed access
MNMeng Ni
Meng Ni
JSJoseph F. Signorile
Joseph F. Signorile
KMKiersten Mooney
Kiersten Mooney
ABAnoop Balachandran
Anoop Balachandran
MPMelanie Potiaumpai
Melanie Potiaumpai
APArlette C. Perry
Arlette C. Perry

1 April 2016 in Complementary Therapies in Medicine
Verified
Journal Article
Closed access
MNMeng Ni
Meng Ni
KMKiersten Mooney
Kiersten Mooney
JSJoseph F. Signorile
Joseph F. Signorile

10 April 2017 in Medical Engineering & Physics
Verified
Journal Article
Closed access
MEMoataz Eltoukhy
Moataz Eltoukhy
CKChristopher Kuenze
Christopher Kuenze
JOJeonghoon Oh
Jeonghoon Oh
MJMarco Jacopetti
Marco Jacopetti
SWSavannah Wooten
Savannah Wooten
JSJoseph Signorile
Joseph Signorile
Gait patterns differ between healthy elders and those with Parkinson's disease (PD). A simple, low-cost clinical tool that can evaluate kinematic differences between these populations would be invaluable diagnostically; since gait analysis in a clinical setting is impractical due to cost and technical expertise. This study investigated the between group differences between the Kinect and a 3D movement analysis system (BTS) and reported validity and reliability of the Kinect v2 sensor for gait analysis. Nineteen subjects participated, eleven without (C) and eight with PD (PD). Outcome measures included spatiotemporal parameters and kinematics. Ankle range of motion for C was significantly less during ankle swing compared to PD (p=0.04) for the Kinect. Both systems showed significant differences for stride length (BTS (C 1.24±0.16, PD=1.01±0.17, p=0.009), Kinect (C=1.24±0.17, PD=1.00±0.18, p=0.009)), gait velocity (BTS (C=1.06±0.14, PD=0.83±0.15, p=0.01), Kinect (C=1.06±0.15, PD=0.83±0.16, p=0.01)), and swing velocity (BTS (C=2.50±0.27, PD=2.12±0.36, p=0.02), Kinect (C=2.32±0.25, PD=1.95±0.31, p=0.01)) between groups. Agreement (RangeICC =0.93-0.99) and consistency (RangeICC =0.94-0.99) were excellent between systems for stride length, stance duration, swing duration, gait velocity, and swing velocity. The Kinect v2 can was sensitive enough to detect between group differences and consistently produced results similar to the BTS system.

1 February 2016 in Parkinsonism & Related Disorders
Verified
Journal Article
Closed access
MNMeng Ni
Meng Ni
JSJoseph F. Signorile
Joseph F. Signorile
ABAnoop Balachandran
Anoop Balachandran
MPMelanie Potiaumpai
Melanie Potiaumpai