8 August 2019 in IEEE Access
An AC-DC-AC topology based on multi-converter is proposed in this paper. It can match the capacity of the converter for high voltage and large power applications. This structure is not only suitable for solving the power quality problems of electrified railways, but also has its own superiorities. Its architecture and advantages in the traction application are analyzed in depth, and the design calculation of the main elements is presented. The control system of the proposed topology is designed, where dc current feedforward control is adopted to relieve the impact of the load mutation on the system. Its modular structure and simple current sharing control provide convenience for the capacity expansion. The software simulation and experiment based on a 45kVA prototype validate the proposed structure, and they are all compared with the traditional power supply systems. The simulation results indicate that this topology can not only satisfy the voltage and power requirements of traction load and solve the power quality problems, but also have its own superiorities in the application of electrified railways. The experimental results verify the correctness and validity of the scheme.
28 April 2020 in IEEE Transactions on Industrial Electronics
Measurements of (inter)harmonic impedances of the traction power supply system (TPSS) play important roles in the validation of TPSS modeling, suppression of resonances, stability analysis of locomotives converters, etc. A harmonic generator (HG) and its construction are proposed in this article to directly measure the impedance of TPSSs. Compared to other experimental setups, the HG can emit a fully controlled single-tone (inter)harmonic current at the high voltage level in a wide frequency range, i.e., at least covering 150-3750 Hz. Field tests have been carried out in the actual 2 × 25 kV railway considering the influence of locations and lengths that are scarcely presented in existing literatures. Both the implementation process and test waveforms have verified the effectiveness and feasibility of the HG. The test results, which denotes that locations do not change the resonant frequency while railway lengths will shift resonant frequencies distinctly, can be a basis for developing techniques aimed to improve the power quality.
16 January 2020 in IEEE Transactions on Energy Conversion
To investigate the harmonic resonance in electric railways, determination of the traction network impedance using a utility instrument is an important and challenging task. This article presents a novel industrial test device which can directly measure the impedance of the actual traction network which is the power source of the railway. The structure arrangement and the parameter design are accomplished to meet the requirements for high-voltage level and strong anti-electromagnetic interference capability. Following this, frequency-dependent impedance measurement is implemented through the injection of controlled harmonic currents using the cascaded H-bridge converters. Furthermore, the power flow analysis is carried out to demonstrate that this device does not need any additional power source and can generate harmonic power. In a new-built railway, this device has been adopted to conduct the on-site test of the traction network impedance. Then, the multi-conductor simulation model is established for the purpose of mutual verification between the field test result and simulation result. Furthermore, the on-site test results can be applied to determine the resonance frequency before a nenw-built line is put into use so that any harmonic resonance can be avoided by taking effective measures in advance.
16 March 2020 in IEEE Access
The inherent resonant frequency of a traction power supply system (TPSS) needs to be accurately identified in order to provide crucial information for resonance suppression, safe operation, and system optimization of electrified railways. In this paper, implementation of experiments was carried out in actual railway systems to evaluate the inherent harmonic resonances of the TPSS. The field tests were based on a harmonic generator (HG) constructed with cascaded H-bridge converters (CHBCs). Compared to other experimental setups, the field tests of this paper, which were performed in the 25kV practical system, can provide straightforward results in a wide frequency range up to 5000 Hz. Such a wide frequency range is necessary for assessing and taking effective measures to address the harmonic resonance problem. The results of this paper will supply valuable data for the modeling of TPSSs and the stability analysis of train converters contributing to improvement of the power quality of electric railways.
8 August 2023 in International Journal of Electrical Power & Energy Systems
16 December 2020 in IEEE Access
To solve the three-phase unbalance and reactive power problems in the electric railway power supply system, this paper proposes a Scott transformer based hypotenuse hybrid traction power system (Scott-HHPS). Compared with other co-phase traction power supply systems, the Scott-HHPS could achieve the same compensation objective with smaller active compensation capacity. The paper analyzes the basic principle and makes a comparison between the Scott-HHPS and typical co-phase power supply system. The mathematical relationships among the load current, power factor and capacity demand in condition of power factor variation and regenerative braking are analyzed. In order to further reduce the compensation capacity of the Scott-HHPS, the partial compensation strategy in respect to the index of power factor and unbalance is proposed. Besides, an instantaneous current detection method based on the theorem of conservation of power is adopted to simplify the control algorithms. Simulations and experiments are both constructed and the results demonstrate that the Scott-HHPS can effectively improve the power quality in the electric railway power supply system.