Minghui Liu

Minghui Liu

Auto-generated profile, based on publicly available information

Minghui Liu

Department of Ultrasound Diagnosis, The Second Xiangya Hospital of Central South University, Changsha, China

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2022 in Ultrasonography
Verified
Journal Article
Open access
PDF file
YGYuyang Guo
Yuyang Guo
BZBaihua Zhao
Baihua Zhao
SZShan Zhou
Shan Zhou
LWLieming Wen
Lieming Wen
JLJieyu Liu
Jieyu Liu
MLMinghui Liu
Minghui Liu
Purpose: This study compared the diagnostic performance of the Ovarian-Adnexal Reporting and Data System (O-RADS), the Risk of Malignancy Index 4 (RMI4), the International Ovarian of Tumor Analysis Logistic Regression Model 2 (IOTA LR2), and the IOTA Simple Rules (IOTA SR) in predicting the malignancy of adnexal masses (AMs).Methods: This retrospective study included 575 women with AMs between 2017 and 2020. All clinical messages, ultrasound images, and pathological findings were collected. Two senior doctors (group I) and two junior doctors (group II) used the four systems to classify AMs. The postoperative pathological diagnosis was used as the gold standard to evaluate the diagnostic efficiency. A receiver operating characteristic curve was used to test the diagnostic performance. The interrater agreement between the two groups was tested using kappa values.Results: Of all 592 AMs, 447 (75.5%) were benign, 123 (20.8%) were malignant, and 22 (3.7%) were borderline. The intergroup consistency test yielded kappa values of 0.71, 0.92, 0.68, and 0.77 for the O-RADS, RMI4, IOTA LR2, and IOTA SR, respectively. To predict malignant lesions, the areas under the curve of the O-RADS, RMI4, IOTA LR2, and IOTA SR systems were 0.90, 0.89, 0.90, and 0.86 for group I and 0.89, 0.87, 0.88, and 0.84 for group II, respectively. The O-RADS had the highest sensitivity (91.0% in group I and 84.8% in group II).Conclusion: The four diagnostic systems could compensate for junior doctors’ inexperience in predicting malignant adnexal lesions. The O-RADS performed best and showed the highest sensitivity.

23 April 2021 in Frontiers in Endocrinology
Verified
Journal Article
Open access
PDF file
YLYiyang Luo
Yiyang Luo
SLShan Liu
Shan Liu
HSHui Su
Hui Su
LHLin Hua
Lin Hua
HRHaiying Ren
Haiying Ren
YLYuan Li
Yuan Li
Objective: To explore the association between serum LH levels and the cumulative live birth rate (CLBR) within one complete cycle, and the impact of serum LH levels on the live birth rate (LBR) after the initial embryo transfer (ET) considering different ET strategies (fresh or freeze-all).Design: A retrospective cohort study.Setting: University-affiliated reproductive center.Patients: 1480 normogonadotrophic women who underwent COS with GnRH antagonist protocol for the first IVF/ICSI attempt.Intervention(s): The sample was stratified into low and higher LH groups according to serum LH peak levels of <4 (Group A) and ≥4 IU/L (Group B) during COS. Patients were also sub-grouped into conventional fresh/frozen ET cycles and freeze-all cycles.Main outcome measure(s): The LBR after the initial embryo transfer and the CLBR within one complete cycle.Secondary outcome measure(s): The numbers of day-3 high-quality embryos, the numbers of embryos available, and the other pregnancy outcomes after the initial ET.Result(s): In the whole cohort, the CLBRs decreased significantly in the low (63.1% vs. 68.3%, P=.034) LH group compared to the higher LH group. Subgroup analysis revealed that patients with low LH levels had lower LBR after fresh ET (38.0% vs. 51.5%, P=.005) but comparable LBR after the first frozen-thawed ET (FET) in freeze-all cycles (49.8% vs. 51.8%, P=.517) than patients with higher LH peak levels. Likewise, patients with low LH levels had lower CLBR for conventional fresh/frozen ET cycles (54.8% vs. 66.1%, P=.015) but comparable CLBR for the freeze-all cycles (66.8% vs. 69.2%, P=.414) than those with higher LH levels. Following confounder adjustment, multivariable regression analyses showed that low LH level was an independent risk factor for the CLBR in the whole cohort (odds ratio (OR): 0.756, 95% confidence interval (CI): 0.604-0.965, P=.014) and in patients who underwent the conventional ET strategy (OR: 0.596, 95% CI: 0.408-0.917, P=.017). Moreover, the adverse impact of low LH levels on LBRs maintained statistically significant after fresh transfers (OR: 0.532, 95% CI: 0.353-0.800, P=.002) but not after the first FETs in freeze-all cycles (OR: 0.918, 95% CI: 0.711-1.183, P=.508).Conclusion(s): In comparison with higher LH levels, low LH levels decrease the CLBRs per oocyte retrieval cycle for normogonadotrophic women who underwent COS using GnRH antagonists. This discrepancy may arise due to the significant detrimental effect of low LH levels on the LBRs after fresh embryo transfers.

8 August 2025 in Balkan Medical Journal
Verified
Journal Article
Open access
BZBaihua Zhao
Baihua Zhao
LWLieming Wen
Lieming Wen
YHYunxia Huang
Yunxia Huang
YFYaqian Fu
Yaqian Fu
SZShan Zhou
Shan Zhou
YLYingjia Li
Yingjia Li
Polycystic ovary syndrome (PCOS) has a significant impact on endocrine metabolism, reproductive function, and mental health in women of reproductive age. Ultrasound remains an essential diagnostic tool for PCOS, particularly in individuals presenting with oligomenorrhea or ovulatory dysfunction accompanied by polycystic ovaries, as well as hyperandrogenism associated with polycystic ovaries. However, the accuracy of ultrasound in identifying polycystic ovarian morphology remains variable. To develop a deep learning model capable of rapidly and accurately identifying PCOS using ovarian ultrasound images. Prospective diagnostic accuracy study. This prospective study included data from 1,751 women with suspected PCOS who presented at two affiliated hospitals at Central South University, with clinical and ultrasound information collected and archived. Patients from center 1 were randomly divided into a training set and an internal validation set in a 7:3 ratio, while patients from center 2 served as the external validation set. Using the YOLOv11 deep learning framework, an automated recognition model for ovarian ultrasound images in PCOS cases was constructed, and its diagnostic performance was evaluated. Ultrasound images from 933 patients (781 from center 1 and 152 from center 2) were analyzed. The mean average precision of the YOLOv11 model in detecting the target ovary was 95.7%, 97.6%, and 97.8% for the training, internal validation, and external validation sets, respectively. For diagnostic classification, the model achieved an F1 score of 95.0% in the training set and 96.9% in both validation sets. The area under the curve values were 0.953, 0.973, and 0.967 for the training, internal validation, and external validation sets respectively. The model also demonstrated significantly faster evaluation of a single ovary compared to clinicians (doctor, 5.0 seconds; model, 0.1 seconds; p < 0.01). The YOLOv11-based automatic recognition model for PCOS ovarian ultrasound images exhibits strong target detection and diagnostic performance. This approach can streamline the follicle counting process in conventional ultrasound and enhance the efficiency and generalizability of ultrasound-based PCOS assessment.

14 April 2020 in International Urogynecology Journal
Verified
Journal Article
Open access
PDF file
LWLieming Wen
Lieming Wen
BZBaihua Zhao
Baihua Zhao
WCWenjie Chen
Wenjie Chen
ZQZhenzhen Qing
Zhenzhen Qing
MLMinghui Liu
Minghui Liu
Introduction and hypothesis: The objective was to describe the behaviour of the bladder neck and proximal urethra during urine leaking in the cough stress test (CST) in supine and standing positions using transperineal ultrasound (TPUS). Method: We carried out prospective data collection and a retrospective data analysis of 102 women with stress urinary incontinence (SUI) who had a positive CST with TPUS in the supine and/or standing position. On TPUS, the behaviour of the bladder neck and proximal urethra was described by the urethral length, urethral funnelling, bladder neck descent (BND), retrovesical angle (RVA) and urethral rotation angle (URA). Differences between the ultrasound findings in the two positions were evaluated. Results: In the 102 women, the mean age was 48 years and mean BMI was 23.8 kg/m2. On TPUS, urine leakage was detected in the supine or standing position in 102 women and in both positions in 81. Between the two positions, significant differences were found in the URA and RVA. In the standing position, the median RVA of 166° was significantly larger than that of 133° in the supine position (p < 0.001), and the median URA of 35° was significantly smaller than that of 64° in the supine position (p < 0.001). Conclusions: TPUS in both positions can be used to detect the real-time behaviour of the bladder neck and urethra in the CST. In the standing position, less rotation and more straightening of the bladder neck and proximal urethra occurred during urine leakage.

3 March 2020 in Journal of Ultrasound in Medicine
Verified
Journal Article
Closed access
PDF file
BZBaihua Zhao
Baihua Zhao
LWLieming Wen
Lieming Wen
WCWenjie Chen
Wenjie Chen
ZQZhenzhen Qing
Zhenzhen Qing
DLDan Liu
Dan Liu
MLMinghui Liu
Minghui Liu

19 July 2024 in Frontiers in Cellular and Infection Microbiology
Verified
Journal Article
Open access
PDF file
MLMing-Hui Liu
Ming-Hui Liu
XGXiaochong Guo
Xiaochong Guo
MSMao-Ling Sun
Mao-Ling Sun
JLJia-Lun Li
Jia-Lun Li
SLShuhan Liu
Shuhan Liu
YPYu-qing Pan
Yu-qing Pan
Introduction: Human cytomegalovirus (HCMV) is the most common viral infection seen in newborns. The major route of transmission for acquired human cytomegalovirus infection is breast milk from mothers who are HCMV seropositive to the infants. Thus, a rapid, economical, and simple method to perform HCMV test in breast milk is crucial and necessary for preventing acquired HCMV infection, especially in underdeveloped regions with limited laboratory resources.Methods: In this study, an effective technique for the detection of HCMV was constructed by combining multienzyme isothermal rapid amplification (MIRA) and lateral flow chromatography strip (LFD). Primers for the conserved HCMV sequence UL83 were utilized for MIRA-LFD testing.Results: Our results showed that the entire MIRA reaction could be completed in 12 minutes at 37°C, and LFD outcomes could be observed visibly after 10 minutes. The detection sensitivity of this method reached 50 copy/μl. Samples of breast milk were examined to compare MIRA-LFD and conventional qPCR. The accuracy of MIRA-LFD was 100%.Discussion: The straightforward, rapid, economic features of the test can provide the significant advantages for the prevention of breast milk-acquired cytomegalovirus infection, particularly in resource-limited locations with high seroprevalence of cytomegalovirus.