Ping Zhong

Ping Zhong

Auto-generated profile, based on publicly available information

Ping Zhong

Department of Urology, China Rehabilitation Research Center, School of Rehabilitation of Capital Medical University, Beijing, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 January 2021 in International Urology and Nephrology
Verified
Journal Article
Closed access
PDF file
YZYan Zhu
Yan Zhu
YZYao-Rui Zhao
Yao-Rui Zhao
PZPing Zhong
Ping Zhong
BQBaomin Qiao
Baomin Qiao
ZYZhi-Qiang Yang
Zhi-Qiang Yang
YNYuanjie Niu
Yuanjie Niu

4 June 2024 in Neurourology and Urodynamics
Verified
Journal Article
Closed access
XLXin Liu
Xin Liu
PZPing Zhong
Ping Zhong
YGYi Gao
Yi Gao
LLLimin Liao
Limin Liao

31 March 2025 in International Neurourology Journal
Verified
Journal Article
Open access
PDF file
XLXin Liu
Xin Liu
PZPing Zhong
Ping Zhong
DCDi Chen
Di Chen
LLLimin Liao
Limin Liao
Purpose: Gold-standard urodynamic examination is widely used in the diagnosis and treatment of lower urinary tract dysfunction. The purpose of urodynamic quality control is to standardize urodynamic examination and ensure its clinical reference value. In our study, we attempted to use a deep learning (DL) algorithm model, mainly for the recognition of typical urodynamic signal, to help physicians complete high-quality urodynamic examinations.Methods: Urodynamic image data from 2 cohorts of adult patients with neurogenic bladder were used: (1) 300 patients with neurogenic bladder in our center from 2012 to 2018 (1,960 images used to train and validate the DL model); and (2) 100 patients with neurogenic bladder from 2020 to 2021 (695 images used to test the performance of the DL model). This resulted in a total of 2,655 images to train, validate and test the DL algorithm to predict the urdynamic signals.Results: Yolov5l had the best detection performance and the highest comprehensive index score (F1, 0.81; mean average precision, 0.83). Our study is a retrospective single-center study, and the generalization ability of the model has not been verified.Conclusions: DL algorithms can help operators identify typical urodynamic signals in real time, improve the interpretation and quality of urodynamic examination, and benefit patients.

29 August 2025 in International Journal of Surgery
Verified
Journal Article
Open access
XLXin Liu
Xin Liu
PZPing Zhong
Ping Zhong
TXTianyu Xiang
Tianyu Xiang
LLLimin Liao
Limin Liao
Background: The diagnosis of neurogenic lower urinary tract dysfunction (NLUTD) is complicated and often misdiagnosed by inexperienced physicians. Therefore, we used deep-learning algorithm models combined with video urodynamics to aid in the diagnosis of male NLUTD patients and construct an automated diagnosis and treatment process for such patients. Methods: The urodynamic data from two cohorts of patients in our center with NLUTD were used: (1) a total of 284 male patients with NLUTD from 2009 to 2019 were used for model training and validation optimization; and (2) a cohort of 100 male patients with NLUTD from 2020 to 2021 were used for model testing. The deep-learning algorithm models were yolov5 and yolov10. Based on pressure-flow traces and cystourethrography images, the qualitative and localization evaluation model of male NLUTD was constructed. Results: For the qualitative assessment of bladder outlet obstruction and detrusor contractility in male NLUTD patients, the best model was yolov10x, and the average precision (mAP) value of all categories was 0.89. For the localization evaluation of bladder outlet obstruction, the best model was yolov5x, and the average mAP value of all categories was 0.83. Conclusions: The yolov10x model can be used for qualitative evaluation of bladder outlet obstruction and detrusor contractility, and the yolov5x model can be used for localization evaluation of bladder outlet obstruction in male NLUTD patients.

28 June 2026 in International Neurourology Journal
Verified
Journal Article
Open access
PZPing Zhong
Ping Zhong
XLXin Liu
Xin Liu
TXTianyu Xiang
Tianyu Xiang
JWJuan Wu
Juan Wu
LLLimin Liao
Limin Liao
Purpose: Upper urinary tract deterioration (UUTD) is a burdensome complication in patients with neurogenic bladder (NB). This study aimed to develop a practical machine learning (ML) tool for assessing UUTD risk.Methods: The study included 2,393 patients with NB who underwent clinical and urodynamic examinations. Of these, 2,001 patients from northern regions of our country were assigned to training and validation sets, and 392 patients from southern regions formed the test set for internal-external validation. Clinical and urodynamic parameters were screened using the Boruta, least absolute shrinkage and selection operator regression, and decision tree algorithms; features identified by all 3 algorithms were used to develop the ML models. Model performance was evaluated using the area under the receiver operating characteristic curve (AUC), calibration curves, and decision curve analysis. SHapley Additive exPlanations analysis provided visual interpretations for individual patients.Results: Six features, notably bladder management method and detrusor sphincter dyssynergia, were identified as risk factors for UUTD. Of the 4 ML algorithms, the Gaussian Naive Bayes (GNB) model had the best overall performance, with AUCs (95% confidence intervals) of 0.884 (0.867–0.901), 0.868 (0.829–0.907), and 0.878 (0.839–0.916) in the training, validation, and test sets, respectively. Subgroup analyses by imaging outcome, NB etiology, and age showed consistent performance of the GNB model, with AUCs ranging from 0.815 to 0.895. The GNB model incorporating the core variables was presented through a practical web-based tool for individualized risk assessment.Conclusions: We developed a ML model to assess UUTD risk in patients with NB. The findings emphasize the importance of combining bladder management method with urodynamic evaluation when assessing UUTD risk, and the model provides a practical tool for individualized assessment. Independent external validation of the model is warranted.

9 September 2025 in International Journal of Surgery
Verified
Journal Article
Open access
ZZZhonghan Zhou
Zhonghan Zhou
THTianyang Hang
Tianyang Hang
JWJuan Wu
Juan Wu
TXTianyu Xiang
Tianyu Xiang
PZPing Zhong
Ping Zhong
LLLimin Liao
Limin Liao
Background: This study aims to analyze bladder morphology features for upper urinary tract dysfunction (UUTD) risk assessment and develop a fully end-to-end (E2E) automated segmentation and risk identification algorithm. Materials and methods: A retrospective cohort of 604 neurogenic bladder patients undergoing video-urodynamics was analyzed. Bladder regions of interest (ROIs) were manually and automatically segmented. Thirty-six morphology features, including shape, Laplacian of Gaussian histograms, and fractal characteristics, were extracted from ROIs. After LASSO regression, selected predictive features were integrated into machine learning models. Model performance was evaluated via the area under the receiver operating characteristic curve (AUC), calibration curves, and decision curve analysis. Results: Based on manually segmented ROI, 28 (77.78%) morphology features exhibited significant differences between different bladder grades. Shape_Perimeter_to_Surface_ratio emerged as the most significant predictor of UUTD (AUC = 0.722, 95% confidence interval [CI]: 0.674–0.769). The support vector machine (SVM) model demonstrated the highest performance, with an AUC of 0.860 (95% CI: 0.820–0.899) in the training cohort and 0.830 (95% CI: 0.744–0.915) in the test cohort, which was significantly higher than the performance of using single features. However, incorporating clinical information did not further enhance the overall predictive performance of the model. To realize a fully E2E approach, a fully convolutional network with a ResNet101 backbone (FCN-ResNet101) was adopted for automated bladder segmentation (dice similarity coefficient [Dice] = 0.9848, mean intersection over union [mIoU] = 0.9705). Morphology features extracted from automated and manual segmentations showed a strong correlation (all r > 0.90). Similarly, machine learning models were developed, with SVM achieving the highest performance (AUC = 0.843, 95% CI: 0.801–0.885 in the training cohort; AUC = 0.815, 95% CI: 0.729–0.900 in the testing cohort). Conclusion: The bladder morphology features are robust predictors of UUTD. This fully automated, E2E bladder segmentation and UUTD risk prediction model demonstrated superior performance compared to traditional clinical parameters, providing a quantitative and objective tool for early risk assessment. Large-scale, multicenter prospective studies are required to validate its clinical applicability and robustness in the future.