This study presents a combined experimental and numerical investigation of fiber transport and deposition in a realistic model of the female respiratory tract, extending to the seventh generation of branching. Numerical simulations were performed using the Euler-Lagrange Euler-Rotation (ELER) method, an efficient alternative to conventional Finite Volume Methods that benefits from explicit formulation and vast scalability, enabling fast parallelization on high-performance clusters. The ELER method was coupled with the Lattice Boltzmann Method (LBM) to simulate fiber dynamics under a realistic inspiratory flow profile. Experimental validation was conducted using an identical physical airway replica. The results demonstrated good agreement between simulations and experiments in the upper airways and trachea, with some discrepancies in the bifurcations, likely owing to the challenges of modeling complex turbulent flow with ELER. This method is more accurate than corresponding effective diameter simulations. Deposition patterns were analyzed as a function of fiber dimensions, revealing higher accuracy of the ELER method for smaller particles and confirming the tendency of higher aspect ratio fibers to penetrate deeper into the lungs. The orientation-dependent deposition mechanism was deployed, underscoring the importance of solving the actual orientations of the fibers. While advancing our understanding of fiber transport in female airways, the findings also reveal limitations in current numerical techniques, particularly in bifurcations. This study emphasizes the distinct behavior of fibrous versus spherical particles, with fibers exhibiting a greater propensity to reach deeper lung regions, which has significant implications for inhalation toxicology and drug delivery.
6 October 2025 in Journal of Drug Delivery Science and Technology
Effervescent atomizers are sensitive to the two-phase flow regime that develops in their mixing chamber, but the link between the regime, discharge stability and drop size is still poorly quantified. The internal flow of a modular transparent atomizer was visualized with a high-speed camera and related the observed regimes to the discharge coefficient (CD) and Sauter mean diameter (D32). The test matrix covered three mixing-chamber diameters (3–12 mm), three exit orifices (0.75–3 mm), seven aerator designs, both outside-in-gas (OIG) and outside-in-liquid (OIL) configurations, gas-to-liquid mass ratios (GLR) of 0.1–10.8% and mixing overpressures of 50–200 kPa. GLR was the strongest predictor of the flow regime; however, bubbly, churn and slug flow coexisted at GLR = 0.1%, while annular flow dominated above 1.2%. Different regimes occurred at nearly identical superficial velocities in the mixing chamber, depending on the aerator and configuration, so published regime maps predicted the transitions only partially. Slug flow raised CD by about 4% and D32 by about 12% relative to churn flow at matched conditions, which links the internal flow structure directly to the discharge behaviour. CD decayed logarithmically with GLR rather than following a power law. Distinction between OIL and OIG configurations was observed for CD and D32. Smaller aerator holes improved atomization in OIG but promoted slug flow in OIL; the two configurations therefore need separate design rules.
Effervescent atomizers are sensitive to the two-phase flow regime that develops in their mixing chamber, but the link between the regime, discharge stability and drop size is still poorly quantified. The internal flow of a modular transparent atomizer was visualized with a high-speed camera and related the observed regimes to the discharge coefficient (CD) and Sauter mean diameter (D32). The test matrix covered three mixing-chamber diameters (3–12 mm), three exit orifices (0.75–3 mm), seven aerator designs, both outside-in-gas (OIG) and outside-in-liquid (OIL) configurations, gas-to-liquid mass ratios (GLR) of 0.1–10.8% and mixing overpressures of 50–200 kPa. GLR was the strongest predictor of the flow regime; however, bubbly, churn and slug flow coexisted at GLR = 0.1%, while annular flow dominated above 1.2%. Different regimes occurred at nearly identical superficial velocities in the mixing chamber, depending on the aerator and configuration, so published regime maps predicted the transitions only partially. Slug flow raised CD by 3–8% and D32 by 15–24% relative to churn flow at matched conditions, which links the internal flow structure directly to the discharge behaviour. CD decayed logarithmically with GLR rather than following a power law. Distinction between OIL and OIG configurations was observed for CD and D32. Smaller aerator holes improved atomization in OIG but promoted slug flow in OIL; the two configurations therefore need separate design rules.