Bendix Christian Harms

Bendix Christian Harms

Auto-generated profile, based on publicly available information

Bendix Christian Harms

Department of Radiology and Biomedical Imaging (G.A.K., M.-C.C., D.Z., B.C.H., E.B., A.M., S.P.), Yale University School of Medicine, New Haven, CT

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2023 in JMIR Human Factors
Verified
Journal Article
Open access
PMPreetha Moorthy
Preetha Moorthy
LWLina Weinert
Lina Weinert
BHBendix Christian Harms
Bendix Christian Harms
CACarolin Anders
Carolin Anders
FSFabian Siegel
Fabian Siegel
Background: Good usability is important for the adoption and continued use of mobile health (mHealth) apps. In particular, high usability can support intuitive use by patients, which improves compliance and increases the app’s effectiveness. However, many usability studies do not use adequate tools to measure perceived usability. The mHealth App Usability Questionnaire (MAUQ) was developed specifically for end users in a medical context. MAUQ is a relatively new but increasingly used questionnaire to evaluate mHealth apps, but it is not yet available in German. Objective: This study aims to translate MAUQ into German and determine its internal consistency, reliability, and construct validity. Methods: This validation study was conducted as part of a usability evaluation project for an mHealth app used as a therapy support tool during breast cancer chemotherapy. MAUQ was translated into German through a rigorous forward-backward translation process, ensuring semantic and conceptual equivalence. Patient responses to MAUQ and System Usability Scale (SUS) were analyzed for validation. Descriptive analysis was performed for the MAUQ subscales and SUS standard scores. Significance tests and correlation coefficients assessed the relationship between the SUS and MAUQ results, confirming construct validity. Internal consistency was assessed for item reliability and consistency in measuring the target construct. Free-text questions assessed translation comprehensibility, with responses analyzed descriptively and qualitatively using content analysis. Results: In this study, 133 participants responded to the questionnaire, and the validation analysis showed substantially positive correlations between the overall MAUQ score and its subscales: ease of use (r=0.56), interface and satisfaction (r=0.75), and usefulness (r=0.83). These findings support the construct validity of MAUQ and emphasize the importance of these subscales in assessing the usability of the Enable app. The correlation coefficients ranging from 0.39 to 0.68 for the items further validate the questionnaire by aligning with the overall score and capturing the intended concept. The high internal consistency reliability of MAUQ (Cronbach α=.81) and its subscales further enhances the instrument’s robustness in accurately evaluating the usability of mHealth apps. Conclusions: We successfully validated the German translation of the MAUQ for stand-alone apps using a standardized approach in a cohort of patients with breast cancer. In our validation study, MAUQ exhibited strong internal consistency reliability (Cronbach α=.81) across its subscales, indicating reliable and consistent measurement. Furthermore, a significant positive correlation (P<.001) was found between the subscales and the overall score, supporting their consistent measurement of the intended construct. Therefore, MAUQ can be considered a reliable instrument for assessing the usability of mHealth apps among German-speaking adults. The availability of the German version of MAUQ will help other researchers in conducting usability studies of mHealth apps in German-speaking cohorts and allow for international comparability of their results.

1 April 2025 in Stroke
Verified
Journal Article
Closed access
GKGaby Abou Karam
Gaby Abou Karam
MCMin-Chiun Chen
Min-Chiun Chen
DZDorin Zeevi
Dorin Zeevi
BHBendix C. Harms
Bendix C. Harms
EBElisa Berson
Elisa Berson
Sam PayabvashSam Payabvash
Sam Payabvash
BACKGROUND: Prior studies on the clinical impact of intracerebral hemorrhage (ICH) location have used visual localization of hematomas to neuroanatomical structures. However, hematomas often cross neuroanatomical structure boundaries with inter-reviewer variability in visual localization. To address these limitations, we applied voxel-wise analysis to identify brain regions where ICH presence is independently predictive of worse outcomes. METHODS: We included consecutive patients with acute spontaneous ICH from a comprehensive stroke center in a derivation cohort and validated the results in patients from the control arm of a multicenter clinical trial. Using general linear models, we created and publicly shared a voxel-wise map of brain regions where ICH presence was associated with higher 3-month modified Rankin Scale scores, independent of hematoma volume and clinical risk factors. We also determined the optimal overlap threshold between baseline hematoma and voxel-wise map to categorize ICH location into high versus low risk. RESULTS: Excluding those with missing variables, head computed tomography processing pipeline failure and poor scan quality, 559 of 780 patients were included in derivation (mean age, 69.3±14.5 years; 311 [55.6%] males) and 345 of 500 (mean age, 62.5±12.9 years; 206 [59.7%] males) in validation cohorts. In a voxel-wise analysis, ICH presence in deep white matter, thalami, caudate, midbrain, and pons was associated with worse outcomes. At the patient level, >22% overlap of baseline hematoma with voxel-wise map optimally binarized ICH location to high- versus low-risk categories. In both the derivation and validation cohorts, a high-risk ICH location was independently associated with worse outcomes (higher 3-month modified Rankin Scale score), after adjusting for patients’ age, symptom severity at admission, baseline hematoma volume, and the presence of intraventricular hemorrhage, with adjusted odds ratios of 2 ([95% CI, 1.3–3.0] P =0.001) and 1.7 ([95% CI, 1.1–2.9] P =0.027), respectively. CONCLUSIONS: We created and publicly shared a voxel-wise map of brain regions where hematoma presence predicts worse outcomes, independent of volume and clinical risk factors.

20 July 2023 in JMIR Preprints
Verified
Preprint
Open access
PMPreetha Moorthy
Preetha Moorthy
LWLina Weinert
Lina Weinert
BHBendix Christian Harms
Bendix Christian Harms
CACarolin Anders
Carolin Anders
FSFabian Siegel
Fabian Siegel
BACKGROUND Good usability is important for the adoption and continued use of mobile health (mHealth) apps. In particular, high usability can support intuitive use by patients, which improves compliance and increases the app’s effectiveness. However, many usability studies do not use adequate tools to measure perceived usability. The mHealth App Usability Questionnaire (MAUQ) was developed specifically for end users in a medical context. MAUQ is a relatively new but increasingly used questionnaire to evaluate mHealth apps, but it is not yet available in German. OBJECTIVE This study aims to translate MAUQ into German and determine its internal consistency, reliability, and construct validity. METHODS This validation study was conducted as part of a usability evaluation project for an mHealth app used as a therapy support tool during breast cancer chemotherapy. MAUQ was translated into German through a rigorous forward-backward translation process, ensuring semantic and conceptual equivalence. Patient responses to MAUQ and System Usability Scale (SUS) were analyzed for validation. Descriptive analysis was performed for the MAUQ subscales and SUS standard scores. Significance tests and correlation coefficients assessed the relationship between the SUS and MAUQ results, confirming construct validity. Internal consistency was assessed for item reliability and consistency in measuring the target construct. Free-text questions assessed translation comprehensibility, with responses analyzed descriptively and qualitatively using content analysis. RESULTS In this study, 133 participants responded to the questionnaire, and the validation analysis showed substantially positive correlations between the overall MAUQ score and its subscales: ease of use (r=0.56), interface and satisfaction (r=0.75), and usefulness (r=0.83). These findings support the construct validity of MAUQ and emphasize the importance of these subscales in assessing the usability of the Enable app. The correlation coefficients ranging from 0.39 to 0.68 for the items further validate the questionnaire by aligning with the overall score and capturing the intended concept. The high internal consistency reliability of MAUQ (Cronbach α=.81) and its subscales further enhances the instrument’s robustness in accurately evaluating the usability of mHealth apps. CONCLUSIONS We successfully validated the German translation of the MAUQ for stand-alone apps using a standardized approach in a cohort of patients with breast cancer. In our validation study, MAUQ exhibited strong internal consistency reliability (Cronbach α=.81) across its subscales, indicating reliable and consistent measurement. Furthermore, a significant positive correlation (P<.001) was found between the subscales and the overall score, supporting their consistent measurement of the intended construct. Therefore, MAUQ can be considered a reliable instrument for assessing the usability of mHealth apps among German-speaking adults. The availability of the German version of MAUQ will help other researchers in conducting usability studies of mHealth apps in German-speaking cohorts and allow for international comparability of their results.