To suppress the arc current in the single line-to-ground (SLG) fault in neutral isolated distribution network, a two-phase current injection method is proposed for the revised static synchronous compensator (STATCOM), as an extra function during the SLG fault. Therefore, the traditional roles of the dedicated passive coil or power electronic based arc-suppression devices can be taken by this multi-purpose STATCOM. This paper first introduces the principles and the models of the arc-suppression current injection during SLG fault. Then, different options of arc-suppression current injection by the revised STATCOM are analyzed in terms of stabilizing the floating dc capacitor voltages of the cascaded H-bridges (CHB) converter. It is discovered that the two-phase current injection is the only viable option to maintain the floating dc capacitors voltages. Then, the arc-suppression current controller and the dc capacitors voltages controller are proposed, and the design process of the control parameters adapting to the varying transitional (grounding) resistances computed online are also introduced. The proposed methods are first validated by simulations. Then, an MVA-rating CHB converter prototype is constructed, and 10kV feeder SLG fault and arc-suppression experiments are performed to demonstrate the effectiveness of the proposed method.
LCL filters have been widely used as the interface between inverters and power grids, but damping methods must be taken to solve the resonance of LCL filters. Considering overcurrent protection and inherent active damping, this paper focuses on the inverter-side current feedback (ICF) control. Some literatures have proposed that the capacitor voltage feedforward (CVF) is beneficial to the stability of the ICF control. However, in practical applications, it is found that the ICF control with CVF mainly faces two problems. Firstly, the CVF can be seen as a positive feedback loop, and it tends to cause low-frequency oscillation, especially in weak grid. Secondly, low-frequency harmonics in the grid voltage can easily distort the grid-side current of the inverter, even though the inverter-side current has been regulated well. In order to solve these two problems simultaneously, this paper proposes a novel inverter-side current control method, which adds a high-pass filter into the CVF path. In this paper, the design process of the high-pass filter parameters is analyzed, and the specific voltage feedforward structure of the proposed method to avoid the inverter startup inrush current is also discussed in detail. Simulations in MATLAB/SIMULINK and experiments based on a 6.6 kW prototype have been utilized to verify the effectiveness of the proposed method.
Three-level neutral-point-clamped (NPC) inverters need to ensure the balance of the neutralpoint (NP) potential during operation. The zero-sequence voltage injection balance algorithms based on the carrier-based pulse width modulation (CBPWM) have been proposed in many papers and proved to be effective in controlling the NP potential. In industrial applications, the algorithms are mostly implemented by digital controllers, which have inherent computation digital delay. However, there is little attention on how the digital delay influences the balance algorithms. In this paper, the influence of the digital delay on the zero-sequence voltage injection balance algorithm has been studied in detail. It is found that the digital delay causes a fluctuation of the NP potential. The frequency of the fluctuation is 1/6 control frequency, and the amplitude of the fluctuation is related to the control frequency, the modulation index, the output current, and the dc-side capacitance. Furthermore, in order to eliminate the NP potential fluctuation caused by the digital delay, a digital delay compensation method is proposed in this paper. The correctness of the theoretical analysis and the effectiveness of the compensation method have been verified by simulation and experiment results.