Khaled Mammar

Khaled Mammar

Auto-generated profile, based on publicly available information

Khaled Mammar

University of Tahri Mohamed Bechar Smart Grids & Renewable Energies, Laboratory SGRE Bechar Bp 417 , Algeria

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2018 in Journal of Energy Storage
Verified
Journal Article
Closed access
SLSlimane Laribi
Slimane Laribi
KMKhaled Mammar
Khaled Mammar
YSYoucef Sahli
Youcef Sahli
KKKhaled Koussa
Khaled Koussa

1 October 2016 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
SLSlimane Laribi
Slimane Laribi
KMKhaled Mammar
Khaled Mammar
MHMessaoud Hamouda
Messaoud Hamouda
YSYoucef Sahli
Youcef Sahli

9 May 2018 in Journal of Electrochemical Energy Conversion and Storage
Verified
Journal Article
Closed access
PDF file
KMKhaled Mammar
Khaled Mammar
SLSlimane Laribi
Slimane Laribi
This work defines and implements a technique to predict water activity in proton exchange membrane fuel cell. This technique is based on the electrochemical impedance spectroscopy (EIS) as sensor and adaptive neuro-fuzzy inference system (ANFIS) as estimator. For this purpose, a proton exchange membrane fuel cell (PEMFC) model has been proposed to study the performances of the fuel cell for different operating conditions where the simulation model for water activity behavior is in the proposed structure. The technique based on ANFIS predicts the PEM fuel cell relative humidity (RH) from the EIS. For creation of ANFIS training and checking database, a new method based on factorial design of experimental is used. To check the proposed technique, the ANFIS estimator will be compared with the output humidity relative observation.

11 August 2022 in Journal of Electrochemical Energy Conversion and Storage
Verified
Journal Article
Closed access
PDF file
FAFatima Zohra Arama
Fatima Zohra Arama
SLSlimane Laribi
Slimane Laribi
KMKhaled Mammar
Khaled Mammar
NANouar Aoun
Nouar Aoun
GTGhaitaoui Touhami
Ghaitaoui Touhami
MHMessaoud Hamouda
Messaoud Hamouda
The identification of water status is the foundation for fuel cell water management, which is helpful to fuel cell reliability and longevity. In this article, a novel and reliable method for diagnosing the hydration condition of proton exchange membrane fuel cells (PEMFCs) was presented using a fractional-order model (FOM) to represent the PEMFCs impedance. The results show that the mean root-mean-squared error (RMSE) and mean absolute percentage error (MAPE) between the proposed model and experimental data (in normal, drying, or flooding cases) are about 0.034 and 0.473, respectively. The fast Fourier transform–electrochemical impedance spectroscopy technique (FFT-EIS) was used as an alternative technique that is simple and efficient to electrochemical impedance spectroscopy (EIS). The PEMFCs hydration state is monitored by observing the changing effect of the physical resistor values (membrane resistance, polarization, and diffusion resistances) of the proposed model. These resistors, characterized by their high sensitivity to the drying and flooding of PEMFCs, affect the Nyquist impedance spectra and frequency spectrum amplitudes at low and high frequencies. Based on the obtained results, it is concluded that the proposed strategy can be used to develop new domains in which the PEMFCs’ hydration states can be properly predicted.

15 November 2013
Verified
Conference Paper
Closed access
PDF file
KMKhaled Mammar
Khaled Mammar
BOBelkacem Ould-Bouamama
Belkacem Ould-Bouamama
Electrochemical impedance spectroscopy (EIS) is a very powerful tool for exploitation as a rich source of Proton Exchange Membrane Fuel Cell (PEMFC) diagnostic information. A primary goal of this work was to develop a suitable PEMFC impedance model, which can be used in the analysis for flooding and drying of fuel cell. For this one a novel optimization method based on factorial Design methodology is used. It was applied for parametric analysis of electrochemical impedance Thus it is possible to evaluate the relative importance of each parameter to the simulation accuracy. Furthermore this work presents an analysis of the PEMFC impedance behavior in the case of flooding and drying.