Christopher L. Antonacci

Christopher L. Antonacci

Auto-generated profile, based on publicly available information

Christopher L. Antonacci

Department of Orthopaedic Surgery, University of Connecticut, Farmington, CT, USA

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2011 in Nature
Verified
Journal Article
Open access
PDF file
SKSonja Kriks
Sonja Kriks
JSJae-Won Shim
Jae-Won Shim
JPJinghua Piao
Jinghua Piao
YGYosif M. Ganat
Yosif M. Ganat
DWDustin R. Wakeman
Dustin R. Wakeman
LSLorenz Studer
Lorenz Studer
A new strategy for derivation of human midbrain dopamine neurons from pluripotent cells was developed; transplantation of the neurons in mice, rats and parkinsonian monkeys show they are a promising source of cells for applications in regenerative medicine. Lorenz Studer and colleagues have developed a new strategy for the efficient derivation of human midbrain dopamine (DA) neurons from pluripotent stem cells. The DA neurons showed functionality in vivo and achieved long-term engraftment in three Parkinson's disease model systems (6-OHDA-lesioned mice and rats, and transplantation into parkinsonian monkeys). The DA neurons are a promising source of cells for applications in regenerative medicine. Human pluripotent stem cells (PSCs) are a promising source of cells for applications in regenerative medicine. Directed differentiation of PSCs into specialized cells such as spinal motoneurons1 or midbrain dopamine (DA) neurons2 has been achieved. However, the effective use of PSCs for cell therapy has lagged behind. Whereas mouse PSC-derived DA neurons have shown efficacy in models of Parkinson’s disease3,4, DA neurons from human PSCs generally show poor in vivo performance5. There are also considerable safety concerns for PSCs related to their potential for teratoma formation or neural overgrowth6,7. Here we present a novel floor-plate-based strategy for the derivation of human DA neurons that efficiently engraft in vivo, suggesting that past failures were due to incomplete specification rather than a specific vulnerability of the cells. Midbrain floor-plate precursors are derived from PSCs 11 days after exposure to small molecule activators of sonic hedgehog (SHH) and canonical WNT signalling. Engraftable midbrain DA neurons are obtained by day 25 and can be maintained in vitro for several months. Extensive molecular profiling, biochemical and electrophysiological data define developmental progression and confirm identity of PSC-derived midbrain DA neurons. In vivo survival and function is demonstrated in Parkinson’s disease models using three host species. Long-term engraftment in 6-hydroxy-dopamine-lesioned mice and rats demonstrates robust survival of midbrain DA neurons derived from human embryonic stem (ES) cells, complete restoration of amphetamine-induced rotation behaviour and improvements in tests of forelimb use and akinesia. Finally, scalability is demonstrated by transplantation into parkinsonian monkeys. Excellent DA neuron survival, function and lack of neural overgrowth in the three animal models indicate promise for the development of cell-based therapies in Parkinson’s disease.

1 June 2024 in Journal of Spine Surgery
Verified
Journal Article
Open access
PDF file
CAChristopher L. Antonacci
Christopher L. Antonacci
FZFrancine Zeng
Francine Zeng
ABAndrew Block
Andrew Block
ADAnnabelle Davey
Annabelle Davey
HMHeeren Makanji
Heeren Makanji
Background and Objective: Emerging technologies have increasingly been adopted in spine surgery in the attempt to increase precision and improve outcomes. Robotic assistance is an area of significant interest, with proposed benefits including increased accuracy, decreased complication rates, and decreased radiation exposure. The purpose of this review is to provide an overview of the currently available robotic assistance systems and their associated outcomes and limitations. Methods: A review of national databases was performed using key terms “robotic”, “spine”, and “surgery” for literature from 2014 to 2023. Studies that aimed to describe the utilities of endoscopic surgeries, associated outcomes, limitations, and future directions were included. Studies that were not in English were excluded. Key Content and Findings: This review includes a brief overview of the history of robotic spine surgery as well as its clinical outcomes, limitations, and future directions. Conclusions: Robotic-assisted spine surgery has seen increasing use in the attempt to increase precision and improve outcomes and has been associated with increased accuracy in pedicle screw placement and decreased complication rates. Barriers to its adoption include a significant learning curve, possibly longer operative cases, and significant associated costs. As robotic assistance continues to become increasingly popular in spine surgery, it is critical for surgeons to understand the technology available and the associated outcomes to make informed decisions when considering which system to incorporate into their practice.

6 March 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
CKCameron Kia
Cameron Kia
CAChristopher L. Antonacci
Christopher L. Antonacci
IWIan James Wellington
Ian James Wellington
HMHeeren S. Makanji
Heeren S. Makanji
SESean M. Esmende
Sean M. Esmende
The use of interbody implants for spinal fusion has been steadily increasing to avoid the risks of complications and donor site morbidity when using autologous bone. Understanding the pros and cons of various implant designs can assist the surgeon in choosing the ideal interbody for each individual patient. The goal of these interbody cages is to promote a surface area for bony ingrowth while having the biomechanical properties to support the axial skeleton. Currently, the majority of interbody implants consists of metal or polyether ether ketone (PEEK) cages with bone graft incorporated inside. Titanium alloy implants have been commonly used, however, the large difference in modulus of elasticity from bone has inherent issues. PEEK implants have a desirable surface area with the benefit of a modulus of elasticity closer to that of bone. Unfortunately, clinically, these devices have had increased risk of subsidence. More recently, 3D printed implants have come into the market, providing mechanical stability with increased surface design for bony ingrowth. While clinical outcomes studies are limited, early results have demonstrated more reliable and quicker fusion rates using 3D custom interbody devices. In this review, we discuss the biology of osseointegration, the use of surface coated implants, as well as the potential benefits of using 3D printed interbodies.

1 February 2021 in Journal of the American Academy of Orthopaedic Surgeons
Verified
Journal Article
Closed access
CAChristopher L. Antonacci
Christopher L. Antonacci
BCBenedict J. Cu
Benedict J. Cu
BEBrandon J. Erickson
Brandon J. Erickson
OVOscar Vazquez
Oscar Vazquez
FAFrank G. Alberta
Frank G. Alberta
Background: Recent studies have demonstrated the safety of anatomic total shoulder arthroplasty (TSA) in an outpatient setting. No clinical studies, to date, have specifically analyzed complication and readmission rates after reverse total shoulder arthroplasty (RTSA) with same-day discharge. The purpose of this study was to compare the 90-day complication and readmission rates of patients undergoing TSA and RTSA with same-day discharge. Methods: Ninety-eight consecutive patients who underwent 104 shoulder arthroplasties with same-day discharge (52 TSA and 52 RTSA) between 2016 and 2019 were analyzed. Suitability for same-day discharge was determined preoperatively using the standardized criteria. Demographic variables, operative time, 90-day readmission, and complication rates were recorded and compared between groups. Differences between the patients undergoing TSA versus RTSA were evaluated with Student t-test, Mann-Whitney test, or Chi square tests as statistically appropriate and reported as P values. Results: Average age in the TSA cohort was significantly lower (60.1 ± 7.4 versus 67.5 ± 7.5, respectively; P < 0.001). Total operating room time was significantly shorter in the RTSA cohort (153 ± 30.1 minutes versus 171 ± 20.9). Three minor postoperative complications (5.8%) were observed in the TSA cohort (three seromas) within the 90-day postoperative period. There were four postoperative complications (7.7%) in the RTSA cohort (two postoperative seromas, one periprosthetic fracture, and one dislocation). None of the TSA patients required readmission and 1 RTSA (periprosthetic fracture) patient required readmission within 90 days. Discussion: RTSA with same-day discharge is a safe option for appropriately selected patients despite significantly increased age. 90-day readmission and complication rates between outpatient TSA and RTSA are similar. Data Availability: Yes. Trial Registration Numbers: NA Level of Evidence: III (case-control)

1 June 2024 in Journal of Spine Surgery
Verified
Journal Article
Open access
PDF file
CAChristopher L. Antonacci
Christopher L. Antonacci
FZFrancine Zeng
Francine Zeng
BFBrian Ford
Brian Ford
IWIan Wellington
Ian Wellington
CKCameron Kia
Cameron Kia
HZHanbing Zhou
Hanbing Zhou
Background and Objective: The concept of endoscopic surgery began in the 1930s and has since undergone numerous advancements in both technology and surgical indications. Its main benefit is providing the opportunity to perform surgery while minimizing disruption to surrounding structures. The purpose of this review is to summarize the history, uses, and future directions for spine endoscopic surgery. Methods: A review of national databases was performing using key terms “endoscopic”, “spine” and “surgery” for literature from 1900 to 2023. Studies that aimed to describe the utilities of endoscopic surgeries, associated outcomes, limitations, and future directions were included. Studies that were not in English were excluded. Key Content and Findings: This review includes a brief overview of the history of endoscopic surgery and its current two main approaches, transforaminal and interlaminar approaches. It then summarizes the main indications and utilization of endoscopic surgery in the lumbar, cervical and thoracic spine, as well as expansion in managing spine tumors, infections, and outpatient surgical cases. Conclusions: There are many rising indications and uses for endoscopic spine surgery in nearly every aspect of the spine. Compared to conventional spine surgery, there is early evidence showing endoscopic surgery is associated with less post-operative pain, shorter hospital stays, and possibly quicker recovery times. As current trends in spine surgery move towards minimally invasive techniques, it is anticipated that the use of endoscopic surgery will continue to expand.

10 August 2023 in Prosthesis
Verified
Journal Article
Open access
PDF file
IWIan James Wellington
Ian James Wellington
CKCaroline Kaufman
Caroline Kaufman
CAChristopher L. Antonacci
Christopher L. Antonacci
ECErgin Coskun
Ergin Coskun
MCMark P. Cote
Mark P. Cote
IMIsaac L Moss
Isaac L Moss
There are a wide variety of interbody devices available for use in transforaminal lumbar interbody fusion (TLIF). While traditionally these interbodies are bullet-shaped, crescent-shaped cages have become increasingly common. There is a paucity of literature comparing the effect of cage geometry with substratification for surgical approach (minimally invasive (MIS) vs. open). The aim of this study was to determine the effect of implant geometry, positioning, and surgical approach on the correction of different spinal alignment parameters in patients undergoing TLIF. A retrospective chart and imaging review was performed on 103 patients with a total of 131 instrumented segments performed by a single surgeon. Preoperative, initial postoperative, and final postoperative standing lateral lumbar radiographs were evaluated for lumbar lordosis (LL), segmental lordosis (SL), anterior disc height (ADH), and posterior disc height (PDH). Anterior-posterior implant positioning was recorded for initial and final postoperative radiographs. These measurements were compared among four groups: open bullet (OB), MIS bullet (MB), open crescent (OC), and MIS crescent (MC). SL increased in all groups by a mean of 2.9° at initial imaging and 2.2° at final imaging. The OC group had greater initial improvement in SL compared to the MB group (p = 0.02), though this effect was lost at final follow-up (p = 0.11). The OB and OC groups conferred greater initial improvement in ADH (p = 0.02; p = 0.04), while the OC group had greater final improvement in ADH compared to the MB and MC groups (p = 0.01; p = 0.01). The OC group had less initial improvement in PDH compared with the other groups (p = 0.03, p = 0.02, p < 0.01). The MB group provided greater final improvement in PDH compared with the MC and OC groups (p = 0.04, p = 0.01). Cage geometry, surgical approach, and implant position all demonstrated a statistically significant but clinically minor impact on segmental alignment for TLIF procedures.