Suturing is required in almost all surgeries but it is challenging to perform with surgical robots due to limited vision and/or haptic feedback. To tackle this problem, we present an autonomous suturing framework that encompasses a novel needle path planner, as well as an accurate needle pose estimator and a six degrees-of-freedom controller. A novel needle grasper is developed that enables needle pose estimation both inside and outside the tissue. The framework was evaluated experimentally using the Raven IV surgical system and important suture parameters were quantified. The experiment results confirmed a needle pose estimation accuracy of < 0.87 mm in position and < 3.46 $^\circ$ in orientation across all directions. Moreover, the results revealed that using the proposed framework enabled following the reference needle trajectories with errors of 2.07 mm in position and 4.29 $^\circ$ in orientation. These are drastic improvements of more than 10× in position and 5× in orientation compared to the Raven IV kinematic controller. Additionally, the results verified that our framework delivered the desired clinical suture parameters successfully across tissue phantom environments with different mechanical properties and under various needle trajectories. A supplementary video can be found at: http://bionics.seas.ucla.edu/research/surgeryproject18.htmlhttp://bionics.seas.ucla.edu/research/surgeryproject18
In autonomous suturing with a surgical robot, needle shape, diameter, and path are critical parameters that directly affect suture depth and tissue trauma. This paper presents an optimization-based approach to specify these parameters. Given clinical suturing guidelines, a kinematic model of needle-tissue interaction was developed to quantify suture parameters and constraints. The model was further used to formulate constant curvature needle path planning as a nonlinear optimization problem. The inputs of the optimization include the tissue geometry, surgeon defined entry/exit points, and optimization weighting factors. The outputs are the needle geometry and suggested path. Off-line simulations were used to evaluate the accuracy and performance of the proposed model, and to determine optimized needle geometry and path for several clinically relevant input sets. The output and the optimization results were confirmed experimentally with the Raven II surgical system. The proposed needle path planning algorithm guarantees minimal tissue trauma and complies with a wide range of suturing requirements.