Tyler Stevens

Tyler Stevens

Auto-generated profile, based on publicly available information

Tyler Stevens

Department of Gastroenterology and Hepatology, Digestive Disease Institute, Cleveland Clinic, Cleveland, OH

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2010 in Gastrointestinal Endoscopy
Verified
Journal Article
Closed access
TSTyler Stevens
Tyler Stevens
RLRocio Lopez
Rocio Lopez
DADouglas G. Adler
Douglas G. Adler
MAMohammad A. Al-Haddad
Mohammad A. Al-Haddad
JCJason Conway
Jason Conway
SVStacie A. Vela
Stacie A. Vela

26 April 2012 in Contrast Media & Molecular Imaging
Verified
Journal Article
Open access
PDF file
NANatalie L. Adolphi
Natalie L. Adolphi
KBKimberly S. Butler
Kimberly S. Butler
DLDebbie M. Lovato
Debbie M. Lovato
TTT. E. Tessier
T. E. Tessier
JTJason E. Trujillo
Jason E. Trujillo
EFEdward R. Flynn
Edward R. Flynn
Both magnetic relaxometry and magnetic resonance imaging (MRI) can be used to detect and locate targeted magnetic nanoparticles, noninvasively and without ionizing radiation. Magnetic relaxometry offers advantages in terms of its specificity (only nanoparticles are detected) and the linear dependence of the relaxometry signal on the number of nanoparticles present. In this study, detection of single‐core iron oxide nanoparticles by superconducting quantum interference device (SQUID)‐detected magnetic relaxometry and standard 4.7 T MRI are compared. The nanoparticles were conjugated to a Her2 monoclonal antibody and targeted to Her2‐expressing MCF7/Her2‐18 (breast cancer cells); binding of the nanoparticles to the cells was assessed by magnetic relaxometry and iron assay. The same nanoparticle‐labeled cells, serially diluted, were used to assess the detection limits and MR relaxivities. The detection limit of magnetic relaxometry was 125 000 nanoparticle‐labeled cells at 3 cm from the SQUID sensors. T2‐weighted MRI yielded a detection limit of 15 600 cells in a 150 µl volume, with r1 = 1.1 mm−1 s−1 and r2 = 166 mm−1 s−1. Her2‐targeted nanoparticles were directly injected into xenograft MCF7/Her2‐18 tumors in nude mice, and magnetic relaxometry imaging and 4.7 T MRI were performed, enabling direct comparison of the two techniques. Co‐registration of relaxometry images and MRI of mice resulted in good agreement. A method for obtaining accurate quantification of microgram quantities of iron in the tumors and liver by relaxometry was also demonstrated. These results demonstrate the potential of SQUID‐detected magnetic relaxometry imaging for the specific detection of breast cancer and the monitoring of magnetic nanoparticle‐based therapies. Copyright © 2012 John Wiley & Sons, Ltd.

26 January 2010 in Digestive Diseases and Sciences
Verified
Journal Article
Closed access
PDF file
TSTyler Stevens
Tyler Stevens
JDJohn A. Dumot
John A. Dumot
MPMansour A. Parsi
Mansour A. Parsi
GZGregory Zuccaro
Gregory Zuccaro
JVJohn J. Vargo
John J. Vargo

1 January 2009 in Clinical Gastroenterology and Hepatology
Verified
Journal Article
Closed access
TSTyler Stevens
Tyler Stevens
JDJohn A. Dumot
John A. Dumot
GZGregory Zuccaro
Gregory Zuccaro
JVJohn J. Vargo
John J. Vargo
MPMansour A. Parsi
Mansour A. Parsi
DCDarwin L. Conwell
Darwin L. Conwell

28 June 2014 in Obesity Surgery
Verified
Journal Article
Closed access
PDF file
AKArthi Kumaravel
Arthi Kumaravel
AZAndrea Zelisko
Andrea Zelisko
PSPhilip Schauer
Philip Schauer
RLRocio Lopez
Rocio Lopez
MKMatthew Kroh
Matthew Kroh
TSTyler Stevens
Tyler Stevens

1 January 2011 in World Journal of Gastroenterology
Verified
Journal Article
Open access
TSTyler Stevens
Tyler Stevens
Hormone-stimulated pancreatic function tests (PFTs) are considered the gold standard for measuring pancreatic exocrine function. PFTs involve the administration of intravenous secretin or cholecystokinin, followed by collection and analysis of pancreatic secretions. Because exocrine function may decline in the earliest phase of pancreatic fibrosis, PFTs are considered accurate for diagnosing chronic pancreatitis. Unfortunately, these potentially valuable tests are infrequently performed except at specialized centers, because they are time consuming and complicated. To overcome these limitations, endoscopic PFT methods have been developed which include aspiration of pancreatic secretions through the suction channel of the endoscope. The secretin endoscopic pancreatic function test (ePFT) involves collection of duodenal aspirates at 15, 30, 45 and 60 min after secretin stimulation. A bicarbonate concentration greater than 80 mmol/L in any of the samples is considered a normal result. The secretin ePFT has demonstrated good sensitivity and specificity compared with various reference standards, including the "Dreiling tube" secretin PFT, endoscopic ultrasound, and surgical histology. Furthermore, a standard autoanalyzer can be used for bicarbonate analysis, which allows the secretin ePFT to be performed at any hospital. The secretin ePFT may complement imaging tests like endoscopic ultrasound (EUS) in the diagnosis of early chronic pancreatitis. This paper will review the literature validating the use of ePFT in the diagnosis of exocrine insufficiency and chronic pancreatitis. Newer developments will also be discussed, including the feasibility of combined EUS/ePFT, the use of cholecystokinin alone or in combination with secretin, and the discovery of new protein and lipid pancreatic juice biomarkers which may complement traditional fluid analysis.