Mauricio Pereira Cantão

Mauricio Pereira Cantão

Auto-generated profile, based on publicly available information

Mauricio Pereira Cantão

Universidade Federal do Paraná (UFPR)

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 1997 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
EKE. M. Kakuno
E. M. Kakuno
NMNey Mattoso
Ney Mattoso
WSW. H. Schreiner
W. H. Schreiner
DMDante H Mosca
Dante H Mosca
MCM. P. Cantão
M. P. Cantão

1 January 2023 in RBRH
Verified
Journal Article
Open access
PDF file
DDDaniel Henrique Marco Detzel
Daniel Henrique Marco Detzel
MBMarcelo Rodrigues Bessa
Marcelo Rodrigues Bessa
LALeandro Avila
Leandro Avila
MCMauricio Pereira Cantão
Mauricio Pereira Cantão
KGKlaus de Geus
Klaus de Geus
This work constitutes one of the outcomes of the “Evaluation of hydrological scenario generation models” activity initiated by the Hydrological Scenario Representation Working Group (GT CH) and coordinated by ONS and CCEE. We introduce the LYNX-Series model, a contemporaneous non-periodic and multivariate variation of the autoregressive moving average model (CARMA) for generating synthetic time series of average inflow discharges to reservoirs in the Brazilian National Interconnected System (SIN). Notably, LYNX-Series couples the synthetic series generator with a multivariate sampling process to select a group of synthetic hydrological scenarios based on a similarity criterion with recent historical data. In addition to reducing the computational burden of the hydrothermal dispatch optimization process, the solution aims to enhance the representativeness of synthetic hydrological scenarios. The paper expounds on the theoretical aspects of the model and presents numerical simulations that validate its ability to replicate hydrological behaviors in various Brazilian basins.

18 November 2021 in Brazilian Journal of Environmental Sciences
Verified
Journal Article
Open access
PDF file
OHOrlando Antonio Duarte Hernandez
Orlando Antonio Duarte Hernandez
APAna Caroline Paula
Ana Caroline Paula
GPGustavo Rafael Collere Possetti
Gustavo Rafael Collere Possetti
MCMauricio Pereira Cantão
Mauricio Pereira Cantão
MAMiguel Mansur Aisse
Miguel Mansur Aisse
This study aims to present the time behavior of wastewater flow parameters, organic matter, biogas flow, biogas composition, and its relations, measured through online sensors, in a municipal wastewater treatment plant (WWTP) operating full-scale upflow anaerobic sludge blanket (UASB) reactors, installed in the south of Brazil. WWTP has online measurement devices to evaluate some physicochemical variables of the sewage and the biogas. The COD analyzer (UV– Vis probe), ultrasonic flow meter, biogas flow meter, and biogas composition analyzer were the equipment used. The monitoring occurred for two time periods each of 72 h and one time period for 48 h in the year 2018. Data were checked with descriptive statistics, data independence was checked through the autocorrelation Box– Ljung test, normality behavior was checked with several tests (Shapiro– Wilk, Kolmogorov–Smirnov, Lilliefors, Anderson–Darling, D’Agostino K2, and Chen–Shapiro), and Spearman’s correlation coefficient was used to evaluate the correlations among the parameters. The mean sewage flow was 345 ± 120 L.s-1; removed organic load was, in average, 48%; biogas quality values were 82.32% ± 3.62% v/v (CH4), 2.66% ± 1.19% v/v (CO2), and 3453 ± 1268 ppm (H2S); and the production per capita obtained was 4.51 ± 1.65 NL.hab-1.d-1. It was estimated an electric power generation of 3118.6 kWh.d-1, which is equivalent to an installed power of 130 KW. The behavior of removed organic load and biogas flow (Nm3.h-1), produced in the treatment plant, showed variable, periodic, and nonstationary time behavior.

1 January 1992
Verified
Book Chapter
Closed access
PDF file
JSJ. H. Dias da Silva
J. H. Dias da Silva
MCM. P. Cantão
M. P. Cantão
JCJ. I. Cisneros
J. I. Cisneros
CLC. S. Lambert
C. S. Lambert
MMM. A. Bica de Moraes
M. A. Bica de Moraes
RMR. P. Mota
R. P. Mota

20 October 2025 in Energy Review: Sustainable Systems for the Future
Verified
Journal Article
Open access
PDF file
MBMarcelo Rodrigues Bessa
Marcelo Rodrigues Bessa
DMDébora Cintia Marcilio
Débora Cintia Marcilio
DDDaniel Henrique Marco Detzel
Daniel Henrique Marco Detzel
TFThelma Solange Piazza Fernandes
Thelma Solange Piazza Fernandes
MCMauricio Pereira Cantão
Mauricio Pereira Cantão
FSFabiano Silva
Fabiano Silva
The process of optimizing the Brazilian hydrothermal system presents an extraordinary challenge, characterized by its continental scale, stochastic flows, and the non-convex nature of hydroelectric generation. Traditional models, based on aggregations of equivalent reservoirs and the linearization of generation functions, have struggled to provide appropriate operational policies in an increasingly complex energy landscape. Furthermore, due to this lack of adherence, the use of the current model as an electricity price setter and a tool for planning the expansion of the Brazilian electricity sector has been questioned by system participants. The Lynx Project introduces a new hierarchical structure designed to overcome these limitations. Its architecture is based on five premises: 1) individual modeling of each hydroelectric reservoir, using nonlinear generation functions to more accurately capture variations in head; 2) the use of fourth-degree polynomial functions to describe the relationships between head, reservoir area, and stored volume; 3) a multi-objective (cost-risk) optimization mechanism that minimizes both the expected operating cost and its respective standard deviation, solved through implicit stochastic optimization supported by the generation of hydrological scenarios; 4) a sophisticated stochastic input module, LYNX-Series, which employs a Contemporary Autoregressive Moving Average (CARMA) model and an original sampling method based on the Mahalanobis distance to select the most hydrologically relevant scenarios in order to reduce computational effort; and 5) an integrated Dynamic Optimal Power Flow (DOPF) model that verifies the feasibility of power dispatch in relation to the physical constraints of the power grid. The main contributions of the Lynx Project include the generation of a set of more appropriate operational policies reflecting different levels of risk aversion, as well as the creation of a powerful analytical tool capable of supporting high-risk strategic decisions in the Brazilian energy sector, including market restructuring and policy analysis.

10 September 2024 in Energy Review: Sustainable Systems for the Future
Verified
Journal Article
Open access
PDF file
MBMarcelo Rodrigues Bessa
Marcelo Rodrigues Bessa
EAEmerson Luís Alberti
Emerson Luís Alberti
AFAndré Luiz Tonso Fabiani
André Luiz Tonso Fabiani
BVBruno Victor Veiga
Bruno Victor Veiga
DDDaniel Henrique Marco Detzel
Daniel Henrique Marco Detzel
VMVictor Gabriel Monteiro
Victor Gabriel Monteiro
A Revisão Ordinária das Garantias Físicas (ROGF) baseia-se no rateio da energia firme para o período crítico oficial. No entanto, o suprimento de energia de uma usina hidrelétrica é um processo estocástico, que depende do comportamento das vazões futuras. E estas podem ter seus parâmetros estocásticos estimados a partir do histórico de vazões passadas. Os objetivos deste projeto são: desenvolver um método estocástico de cálculo de GF de usinas hidrelétricas do Complexo Energético do Fundão e Santa Clara no Paraná, e estudar a real capacidade de geração de cada turbina, por meio da simulação física da operação. Os valores de queda líquida obtidos pela equipe diferem daqueles usados no NEWAVE: 10% acima (Santa Clara) e 2% abaixo (Fundão). Os rendimentos são entre 2% e 4% maiores. O excedente de geração é avaliado como um parâmetro de aderência entre os resultados obtidos pela equipe e os valores da ROGF, verificando-se que o modelo proposto reduz a distorção produzida pela revisão oficial. Estes estudos balizam a análise crítica do mecanismo de revisão baseado nos modelos computacionais do setor elétrico.