Shun Liu

Shun Liu

Auto-generated profile, based on publicly available information

Shun Liu


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2025 in Physics of Fluids
Verified
Journal Article
Closed access
JGJiarong Gu
Jiarong Gu
BGBo Gao
Bo Gao
Ning ZhangNing Zhang
Ning Zhang
SLShun Liu
Shun Liu
DNDan Ni
Dan Ni
WZWenjie Zhou
Wenjie Zhou
To reveal the contribution of flow-induced noise sources and their spatial distribution characteristics in a centrifugal pump, the broadband noise source model and the acoustic analogy method coupled with large eddy simulation and finite element method are applied to investigate the dipole source and quadrupole source under the nominal condition. The validity of the numerical method is verified through measurements of flow-induced noise. Results demonstrate that the sound power of the dipole source is significantly higher than that of the quadrupole source caused by turbulence and vortices, with the main noise source regions identified as the blade suction side and the spiral section of volute. Flow-induced noise in the frequency domain exhibits a combination of broadband components and discrete components, with the discrete components being the blade passing frequency (fBPF) and its harmonics. The blade dipole source exhibits dense discrete spectrum, with discrete components also including subharmonics of the fBPF. At the inlet and outlet, the contribution of blade dipole to low-frequency noise is significantly greater than the volute dipole. As the frequency increases, the contribution of the volute dipole gradually rises. When the frequency exceeds 20 times the fBPF, the dominant noise component shifts to the volute dipole, a phenomenon that is more pronounced at the outlet. The intensity of noise inside the volute is lower than that at the pump inlet and outlet, with the blade dipole as the dominant source, which exhibits a sound pressure level at the fBPF that even surpasses the total noise.

1 January 2025 in Physics of Fluids
Verified
Journal Article
Closed access
SLShun Liu
Shun Liu
JCJing Chen
Jing Chen
BOBas Van Oudheusden
Bas Van Oudheusden
JXJinglei Xu
Jinglei Xu
FSFerry Schrijer
Ferry Schrijer
BGBo Gao
Bo Gao
In this paper, a non-intrusive pressure measurement scheme based on particle image velocimetry (PIV) is presented for the complex supersonic flows with intense shock systems, by elaborately combining the MacCormack method, the streamline-based method, and the spatial integration in conservative form. According to the detailed analyses of flow structures, the pressure fields are well reconstructed by the proposed scheme for the two typical shock-wave/boundary-layer interactions containing regular and Mach reflections, which are induced by the relatively strong oblique shock waves generated by the wedges of 21° and 17° in the freestreams of Mach 2.5 and 2.0, respectively. Based on the theoretical solutions by oblique shock relationship, free interaction theory, and shock polar analysis, this pressure reconstruction scheme is completely validated to effectively suppress the propagation of PIV velocity error to the pressure field and the accumulation of reconstructed pressure error behind the strong shock wave. Compared with the literature presently, this work would be the most challenging application of PIV-based pressure measurement to such complex supersonic flows with intense shock reflections, large oscillations, wide speed ranges, and various compressible flow structures. These good results could confirm the feasibility and high accuracy of the proposed reconstruction scheme and may greatly promote its applications in academic research and engineering test for supersonic flows in the future.

1 December 2025 in Physics of Fluids
Verified
Journal Article
Closed access
JGJiarong Gu
Jiarong Gu
BGBo Gao
Bo Gao
Ning ZhangNing Zhang
Ning Zhang
SLShun Liu
Shun Liu
DNDan Ni
Dan Ni
WZWenjie Zhou
Wenjie Zhou
The staggered impeller (SI) is an effective strategy for enhancing flow stability, improving energy efficiency, and suppressing pressure pulsations in double-suction pumps. In the present paper, SI in an end-suction centrifugal pump is proposed. Its effect on the acoustic signature is investigated using an acoustic analogy method combined with the broadband noise source model. The correlation between flow structures and acoustic responses is clarified by integrating the λ2 criterion and the Lamb vector analysis, thereby revealing the noise reduction mechanism associated with the SI design. These results demonstrate that, compared to the normal impeller, the SI leads to a significant reduction in acoustic power on the blade surfaces, particularly on the pressure side, while the contribution from quadrupole sources remains negligible. The staggered configuration exhibits a pronounced effect in suppressing low-frequency noise. The reductions in sound pressure level at the blade-passing frequency reach 21% at the pump inlet and 20.9% at the outlet. Across the entire frequency range, the average reduction in overall sound pressure level is 13.9%, with the most significant decrease observed in the intensity of the volute dipole. The internal flow analysis confirms that the periodic shedding of wake flow and its interaction with the tongue are the dominant excitation source of pump noise. The interaction between the wake shed from staggered blades not only improves the circumferential uniformity of velocity distribution at impeller outlet and weakens the shedding intensity of the wake flow, but also alters the pattern of rotor–stator interaction, ultimately achieving the effective suppression of flow-induced noise.

1 October 2025 in Physics of Fluids
Verified
Journal Article
Closed access
SLShun Liu
Shun Liu
JCJing Chen
Jing Chen
JXJinglei Xu
Jinglei Xu
BGBo Gao
Bo Gao
In this paper, a non-intrusive load determination approach tailored for supersonic airfoils is proposed based on the control volume (CV) method and the velocity field measured by particle image velocimetry (PIV). Compared with the general rectangle-CV (RCV) method, this approach demonstrates significant advantages in supersonic flows, by adopting a novel streamline-CV (SCV) combined with the streamline-based (SLB) pressure reconstruction method. The SLB method improves the reconstruction accuracy of the pressure distribution along the SCV contour, which is beneficial for supersonic lift determination. As the drag is much smaller than the lift for slender models, it is more difficult to achieve high accuracy and robustness in drag determination. This problem can be solved using a novel streamtube-based correction scheme for the mass flow distribution along the SCV contour, to improve the accuracy of the momentum flux integral. The feasibility of the SCV+SLB approach is theoretically analyzed using the velocity field around a supersonic double wedge airfoil with an angle of attack of 6°. Then, based on synthetic velocity fields with a Gaussian distributed error of 1%, the mean coefficients and their standard deviations are determined and evaluated in detail, demonstrating the superior accuracy and robustness of this approach. Finally, a PIV experiment is conducted in a supersonic wind tunnel to verify the practical performance of the method. The SCV+SLB approach performs well, with relative errors of 3.74% and 5.24% in lift and drag determination, whereas the RCV method fails to produce valid results under the same conditions.