Lidi Ma

Lidi Ma

Auto-generated profile, based on publicly available information

Lidi Ma

State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center , Guangzhou , China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2022 in Neuro-Oncology
Verified
Journal Article
Open access
PDF file
SYShaohan Yin
Shaohan Yin
XLXiao Luo
Xiao Luo
YYYadi Yang
Yadi Yang
YSYing Shao
Ying Shao
LMLidi Ma
Lidi Ma
CXChuanmiao Xie
Chuanmiao Xie
Accurate detection is essential for brain metastasis (BM) management, but manual identification is laborious. This study developed, validated, and evaluated a BM detection (BMD) system. Five hundred seventy-three consecutive patients (10 448 lesions) with newly diagnosed BMs and 377 patients without BMs were retrospectively enrolled to develop a multi-scale cascaded convolutional network using 3D-enhanced T1-weighted MR images. BMD was validated using a prospective validation set comprising an internal set (46 patients with 349 lesions; 44 patients without BMs) and three external sets (102 patients with 717 lesions; 108 patients without BMs). The lesion-based detection sensitivity and the number of false positives (FPs) per patient were analyzed. The detection sensitivity and reading time of three trainees and three experienced radiologists from three hospitals were evaluated using the validation set. The detection sensitivity and FPs were 95.8% and 0.39 in the test set, 96.0% and 0.27 in the internal validation set, and ranged from 88.9% to 95.5% and 0.29 to 0.66 in the external sets. The BMD system achieved higher detection sensitivity (93.2% [95% CI, 91.6–94.7%]) than all radiologists without BMD (ranging from 68.5% [95% CI, 65.7–71.3%] to 80.4% [95% CI, 78.0–82.8%], all P < .001). Radiologist detection sensitivity improved with BMD, reaching 92.7% to 95.0%. The mean reading time was reduced by 47% for trainees and 32% for experienced radiologists assisted by BMD relative to that without BMD. BMD enables accurate BM detection. Reading with BMD improves radiologists’ detection sensitivity and reduces their reading times.

11 July 2024 in Neuro-Oncology
Verified
Journal Article
Open access
PDF file
XLXiao Luo
Xiao Luo
YYYadi Yang
Yadi Yang
SYShaohan Yin
Shaohan Yin
HLHui Li
Hui Li
YSYing Shao
Ying Shao
CXChuanmiao Xie
Chuanmiao Xie
Artificial intelligence has been proposed for brain metastasis (BM) segmentation but it has not been fully clinically validated. The aim of this study was to develop and evaluate a system for BM segmentation. A deep-learning-based BM segmentation system (BMSS) was developed using contrast-enhanced MR images from 488 patients with 10338 brain metastases. A randomized crossover, multi-reader study was then conducted to evaluate the performance of the BMSS for BM segmentation using data prospectively collected from 50 patients with 203 metastases at 5 centers. Five radiology residents and 5 attending radiologists were randomly assigned to contour the same prospective set in assisted and unassisted modes. Aided and unaided Dice similarity coefficients (DSCs) and contouring times per lesion were compared. The BMSS alone yielded a median DSC of 0.91 (95% confidence interval, 0.90–0.92) in the multi-center set and showed comparable performance between the internal and external sets (P = .67). With BMSS assistance, the readers increased the median DSC from 0.87 (0.87–0.88) to 0.92 (0.92–0.92) (P < .001) with a median time saving of 42% (40–45%) per lesion. Resident readers showed a greater improvement than attending readers in contouring accuracy (improved median DSC, 0.05 [0.05–0.05] vs 0.03 [0.03–0.03]; P < .001), but a similar time reduction (reduced median time, 44% [40–47%] vs 40% [37–44%]; P = .92) with BMSS assistance. The BMSS can be optimally applied to improve the efficiency of brain metastasis delineation in clinical practice.

28 February 2022 in Frontiers in Oncology
Verified
Journal Article
Open access
LMLidi Ma
Lidi Ma
KDKan Deng
Kan Deng
CZCheng Zhang
Cheng Zhang
HLHaixia Li
Haixia Li
YLYingwei Luo
Yingwei Luo
CXChuanmiao Xie
Chuanmiao Xie
Background: Few studies have focused on the prognosis of patients with hepatocellular carcinoma (HCC) of Barcelona Clinic Liver Cancer (BCLC) stage 0‒C in terms of early recurrence and 5-years overall survival (OS). We sought to develop nomograms for predicting 5-year OS and early recurrence after curative resection of HCC, based on a clinicopathological‒radiological model. We also investigated whether different treatment methods influenced the OS of patients with early recurrence. Methods: Retrospective data, including clinical pathology, radiology, and follow-up data, were collected for 494 patients with HCC who underwent hepatectomy. Nomograms estimating OS and early recurrence were constructed using multivariate Cox regression analysis, based on the random survival forest (RSF) model. We evaluated the discrimination and calibration abilities of the nomograms using concordance indices (C-index), calibration curves, and Kaplan‒Meier curves. OS curves of different treatments for patients who had recurrence within 2 years after curative surgery were depicted and compared using the Kaplan–Meier method and the log-rank test. Results: Multivariate Cox regression revealed that BCLC stage, non-smooth margin, maximum tumor diameter, age, aspartate aminotransferase levels, microvascular invasion, and differentiation were prognostic factors for OS and were incorporated into the nomogram with good predictive performance in the training (C-index: 0.787) and testing cohorts (C-index: 0.711). A nomogram for recurrence-free survival was also developed based on four prognostic factors (BCLC stage, non-smooth margin, maximum tumor diameter, and microvascular invasion) with good predictive performance in the training (C-index: 0.717) and testing cohorts (C-index: 0.701). In comparison to the BCLC staging system, the C-index (training cohort: 0.787 vs. 0.678, 0.717 vs. 0.675; external cohort 2: 0.748 vs. 0.624, 0.729 vs. 0.587 respectively, for OS and RFS; external cohort1:0.716 vs. 0.627 for RFS, all p value<0.05), and model calibration curves all showed improved performance. Patients who underwent surgery after tumor recurrence had a higher reOS than those who underwent comprehensive treatments and supportive care. Conclusions: The nomogram, based on clinical, pathological, and radiological factors, demonstrated good accuracy in estimating OS and recurrence, which can guide follow-up and treatment of individual patients. Reoperation may be the best option for patients with recurrence in good condition.

9 August 2022 in Neuro-Oncology
Verified
Journal Article
Open access
PDF file
XLXiao Luo
Xiao Luo
YYYadi Yang
Yadi Yang
SYShaohan Yin
Shaohan Yin
HLHui Li
Hui Li
WZWeijing Zhang
Weijing Zhang
CXChuanmiao Xie
Chuanmiao Xie
Errors have seldom been evaluated in computer-aided detection on brain metastases. This study aimed to analyze false negatives (FNs) and false positives (FPs) generated by a brain metastasis detection system (BMDS) and by readers. A deep learning-based BMDS was developed and prospectively validated in a multicenter, multireader study. Ad hoc secondary analysis was restricted to the prospective participants (148 with 1,066 brain metastases and 152 normal controls). Three trainees and 3 experienced radiologists read the MRI images without and with the BMDS. The number of FNs and FPs per patient, jackknife alternative free-response receiver operating characteristic figure of merit (FOM), and lesion features associated with FNs were analyzed for the BMDS and readers using binary logistic regression. The FNs, FPs, and the FOM of the stand-alone BMDS were 0.49, 0.38, and 0.97, respectively. Compared with independent reading, BMDS-assisted reading generated 79% fewer FNs (1.98 vs 0.42, P < .001); 41% more FPs (0.17 vs 0.24, P < .001) but 125% more FPs for trainees (P < .001); and higher FOM (0.87 vs 0.98, P < .001). Lesions with small size, greater number, irregular shape, lower signal intensity, and located on nonbrain surface were associated with FNs for readers. Small, irregular, and necrotic lesions were more frequently found in FNs for BMDS. The FPs mainly resulted from small blood vessels for the BMDS and the readers. Despite the improvement in detection performance, attention should be paid to FPs and small lesions with lower enhancement for radiologists, especially for less-experienced radiologists.