Sandrine Fleury-Souverain

Sandrine Fleury-Souverain

Auto-generated profile, based on publicly available information

Sandrine Fleury-Souverain

Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2017 in The Analyst
Verified
Journal Article
Closed access
PDF file
NGNicolas Guichard
Nicolas Guichard
DGDavy Guillarme
Davy Guillarme
PBPascal Bonnabry
Pascal Bonnabry
SFSandrine Fleury-Souverain
Sandrine Fleury-Souverain
We provide an overview of the analytical methods available for the quantification of antineoplastic drugs in pharmaceutical formulations, biological and environmental samples.

24 June 2011 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
SNSusanne Nussbaumer
Susanne Nussbaumer
LGLaurent Geiser
Laurent Geiser
FSFarshid Sadeghipour
Farshid Sadeghipour
DHDenis Hochstrasser
Denis Hochstrasser
PBPascal Bonnabry
Pascal Bonnabry
SFSandrine Fleury-Souverain
Sandrine Fleury-Souverain

14 May 2013 in Journal of Oncology Pharmacy Practice
Verified
Journal Article
Closed access
SFSandrine Fleury-Souverain
Sandrine Fleury-Souverain
SNSusanne Nussbaumer
Susanne Nussbaumer
MMMarc Mattiuzzo
Marc Mattiuzzo
PBPascal Bonnabry
Pascal Bonnabry
Introduction: The external contamination and cross-contamination by cytotoxic drugs on the surface (outside and septum) of 133 vials from various manufacturers and available on the Swiss market were evaluated. All of the tested vials contained one of the following active ingredients: cyclophosphamide, cytarabine, doxorubicin, epirubicin, etoposide phosphate, gemcitabine, ifosfamide, irinotecan, methotrexate or vincristine. Methods and materials: The validated wiping liquid chromatography-mass spectrometry method used in this study allowed for the simultaneous determination of these 10 cytotoxic drugs in less than 30 min. Results: External contamination by cytotoxic drugs was detected on 63% of tested vials (outside and septum). The highest contamination level was observed on etoposide phosphate vials with 1896.66 ng of active ingredient on the outside of the vial. Approximately 20% of the contaminated vials had greater than 10 ng of cytotoxic drugs. Chemical contamination on the septum was detected on 38% of the vials. No contamination or very low levels of cytotoxic drugs, less than 1 ng per vial, were detected on the vials protected by plastic shrink-wrap. Traces of cytotoxic drugs different from the active ingredient were detected on 35% of the tested vials. Conclusion: Handling cytotoxic vials with gloves and having a procedure for the decontamination of vials are of the utmost importance for reducing exposure to cytotoxic drugs. Moreover, manufacturers must improve their procedures to provide products free from any contamination.

9 July 2016 in Journal of Oncology Pharmacy Practice
Verified
Journal Article
Closed access
LCLaurent Carrez
Laurent Carrez
LBLucie Bouchoud
Lucie Bouchoud
SFSandrine Fleury-Souverain
Sandrine Fleury-Souverain
CCChristophe Combescure
Christophe Combescure
LFLudivine Falaschi
Ludivine Falaschi
PBPascal Bonnabry
Pascal Bonnabry
Centralized chemotherapy preparation units have established systematic strategies to avoid errors. Our work aimed to evaluate the accuracy of manual preparations associated with different control methods. A simulation study in an operational setting used phenylephrine and lidocaine as markers. Each operator prepared syringes that were controlled using a different method during each of three sessions (no control, visual double-checking, and gravimetric control). Eight reconstitutions and dilutions were prepared in each session, with variable doses and volumes, using different concentrations of stock solutions. Results were analyzed according to qualitative (choice of stock solution) and quantitative criteria (accurate, 30% deviation). Eleven operators carried out 19 sessions. No final preparation (n = 438) contained a wrong drug. The protocol involving no control failed to detect 1 of 3 dose errors made and double-checking failed to detect 3 of 7 dose errors. The gravimetric control method detected all 5 out of 5 dose errors. The accuracy of the doses measured was equivalent across the control methods (p = 0.63 Kruskal–Wallis). The final preparations ranged from 58% to 60% accurate, 25% to 27% weakly accurate, 14% to 17% inaccurate and 0.9% wrong. A high variability was observed between operators. Gravimetric control was the only method able to detect all dose errors, but it did not improve dose accuracy. A dose accuracy with <5% deviation cannot always be guaranteed using manual production. Automation should be considered in the future.

15 May 2015 in Annals of Occupational Hygiene
Verified
Journal Article
Closed access
PDF file
MAMarco Anastasi
Marco Anastasi
SRSerge Rudaz
Serge Rudaz
TLThomas Queruau Lamerie
Thomas Queruau Lamerie
POPascal Odou
Pascal Odou
PBPascal Bonnabry
Pascal Bonnabry
SFSandrine Fleury-Souverain
Sandrine Fleury-Souverain
Objective: This study aimed to evaluate two cleaning solutions for the chemical decontamination of antineoplastic agents on the surfaces of two biosafety cabinets routinely used for chemotherapy preparation in a hospital pharmacy. Methods: For almost 1 year (49 weeks), two different solutions were used for the weekly cleaning of two biosafety cabinets in a hospital pharmacy’s centralized cytotoxic preparation unit. The solutions evaluated were a commercial solution of isopropyl alcohol (IPA) and water (70:30, vol:vol), and a detergent solution constituted by 10–2M of sodium dodecyl sulfate (SDS) with 20% IPA. Seven areas in each biosafety cabinet were wiped 14 times throughout the year, before and after the weekly cleaning process, according to a validated procedure. Samples were analyzed using a validated method of high-performance liquid chromatography coupled to mass spectrometry. The decontamination efficacy of these two solutions was tested for 10 antineoplastic agents: cytarabine, gemcitabine, methotrexate, etoposide phosphate, irinotecan, cyclophosphamide, ifosfamide, doxorubicin, epirubicin, and vincristine. Results: Overall decontamination efficacies observed were 82±6% and 49±11% for SDS solution and IPA, respectively. Higher contamination levels were distributed on areas frequently touched by the pharmacy technicians—such as sleeves and airlock handles—than on scale plates, gravimetric control hardware, and work benches. Detected contaminations of cyclophosphamide, ifosfamide, gemcitabine, and cytarabine were higher than those of the others agents. SDS solution was almost 20% more efficient than IPA on eight of the antineoplastic agents. Conclusion: Both cleaning solutions were able to reduce contamination levels in the biosafety cabinets. The efficacy of the solution containing an anionic detergent agent (SDS) was shown to be generally higher than that of IPA and, after the SDS cleaning procedure, biosafety cabinets demonstrated acceptable contamination levels.

4 February 2010 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
SNSusanne Nussbaumer
Susanne Nussbaumer
SFSandrine Fleury-Souverain
Sandrine Fleury-Souverain
LBLucie Bouchoud
Lucie Bouchoud
SRSerge Rudaz
Serge Rudaz
PBPascal Bonnabry
Pascal Bonnabry
JVJean-Luc Veuthey
Jean-Luc Veuthey