Ivan Duran

Ivan Duran

Auto-generated profile, based on publicly available information

Ivan Duran

Institute of Plasma Physics of the CAS

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 April 2022 in Fusion Engineering and Design
Verified
Journal Article
Open access
WBW. Biel
W. Biel
MAM. Ariola
M. Ariola
IBI. Bolshakova
I. Bolshakova
KBK.J. Brunner
K.J. Brunner
MCM. Cecconello
M. Cecconello
HZH. Zohm
H. Zohm

1 August 2021 in Fusion Engineering and Design
Verified
Journal Article
Open access
PVP. Vondracek
P. Vondracek
RPR. Panek
R. Panek
MHM. Hron
M. Hron
JHJ. Havlicek
J. Havlicek
VWV. Weinzettl
V. Weinzettl
HZH. Zhang
H. Zhang

21 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
SESlavomir Entler
Slavomir Entler
ZSZbynek Soban
Zbynek Soban
IDIvan Duran
Ivan Duran
KKKarel Kovarik
Karel Kovarik
KVKarel Vyborny
Karel Vyborny
PSPetr Sladek
Petr Sladek
Ceramic-chromium Hall sensors represent a temperature and radiation resistant alternative to Hall sensors based on semiconductors. Demand for these sensors is presently motivated by the ITER and DEMO nuclear fusion projects. The developed ceramic-chromium Hall sensors were tested up to a temperature of 550 °C and a magnetic field of 14 T. The magnitude of the sensitivity of the tested sensor was 6.2 mV/A/T at 20 °C and 4.6 mV/A/T at 500 °C. The sensitivity was observed to be weakly dependent on a temperature above 240 °C with an average temperature coefficient of 0.014%/°C and independent of the magnetic field with a relative average deviation below the measurement accuracy of 0.086%. A simulation of a neutron-induced transmutation was performed to assess changes in the composition of the chromium. After 5.2 operational years of the DEMO fusion reactor, the transmuted fraction of the chromium sensitive layer was found to be 0.27% at the most exposed sensor location behind the divertor cassette with a neutron fluence of 6.08 × 1025 n/m2. The ceramic-chromium Hall sensors show the potential to be suitable magnetic sensors for environments with high temperatures and strong neutron radiation.

24 October 2016 in Review of Scientific Instruments
Verified
Journal Article
Closed access
IĎI. Ďuran
I. Ďuran
SES. Entler
S. Entler
MKM. Kohout
M. Kohout
MKM. Kočan
M. Kočan
GVG. Vayakis
G. Vayakis
Performance of bismuth Hall sensors developed for the ITER steady state magnetic diagnostic was investigated for high magnetic fields in the range ±7 T. Response of the sensors to the magnetic field was found to be nonlinear particularly within the range ±1 T. Significant contribution of the planar Hall effect to the sensors output voltage causing undesirable cross field sensitivity was identified. It was demonstrated that this effect can be minimized by the optimization of the sensor geometry and alignment with the magnetic field and by the application of “current-spinning technique.”

1 April 2022 in Nuclear Fusion
Verified
Journal Article
Open access
PDF file
MHM. Hron
M. Hron
JAJ. Adámek
J. Adámek
JCJ. Cavalier
J. Cavalier
RDR. Dejarnac
R. Dejarnac
OFOndřej Ficker
Ondřej Ficker
SZS. Zoletnik
S. Zoletnik
COMPASS addressed several physical processes that may explain the behaviour of important phenomena. This paper presents results related to the main fields of COMPASS research obtained in the recent two years, including studies of turbulence, L–H transition, plasma material interaction, runaway electron, and disruption physics: Tomographic reconstruction of the edge/SOL turbulence observed by a fast visible camera allowed to visualize turbulent structures without perturbing the plasma. Dependence of the power threshold on the X-point height was studied and related role of radial electric field in the edge/SOL plasma was identified. The effect of high-field-side error fields on the L–H transition was investigated in order to assess the influence of the central solenoid misalignment and the possibility to compensate these error fields by low-field-side coils. Results of fast measurements of electron temperature during ELMs show the ELM peak values at the divertor are around 80% of the initial temperature at the pedestal. Liquid metals were used for the first time as plasma facing material in ELMy H-mode in the tokamak divertor. Good power handling capability was observed for heat fluxes up to 12 MW m−2 and no direct droplet ejection was observed. Partial detachment regime was achieved by impurity seeding in the divertor. The evolution of the heat flux footprint at the outer target was studied. Runaway electrons were studied using new unique systems—impact calorimetry, carbon pellet injection technique, wide variety of magnetic perturbations. Radial feedback control was imposed on the beam. Forces during plasma disruptions were monitored by a number of new diagnostics for vacuum vessel (VV) motion in order to contribute to the scaling laws of sideways disruption forces for ITER. Current flows towards the divertor tiles, incl. possible short-circuiting through PFCs, were investigated during the VDE experiments. The results support ATEC model and improve understanding of disruption loads.

8 August 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
SESlavomir Entler
Slavomir Entler
JSJ. Sebek
J. Sebek
IDI. Duran
I. Duran
KVKarel Vyborny
Karel Vyborny
OGO. Grover
O. Grover
GVG. Vayakis
G. Vayakis
The ITER outer vessel steady-state magnetic field sensor diagnostics consist of sixty sensor units. Each sensor unit features a pair of ceramic-metal Hall sensors with a sensing layer made of bismuth. The sensors were tested simultaneously in the magnetic field ranging from −12 T to +12 T at the temperature range from 27 to 127 °C. The Hall coefficient and magnetoresistance of the bismuth layer related to the sensors were identified. In the sensor operating conditions, the Hall coefficient dependence on temperature was fitted with an exponential function with a relative error of less than 0.08%, and the dependence on the magnetic field was fitted with a Gaussian-like function with a relative error of less than 0.11%. An alternative expression based on the physical understanding of the free charge carrier transport in semimetals was derived to describe the dependence of the Hall coefficient on the magnetic field, and its fitting error of 1.2 mT in terms of the magnetic field measurement has met the ITER measurement accuracy requirements.