Irene Zyrichidou

Irene Zyrichidou

Auto-generated profile, based on publicly available information

Irene Zyrichidou

Aristotle University of Thessaloniki

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 September 2016 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
ABAnne Boynard
Anne Boynard
DHDaniel Hurtmans
Daniel Hurtmans
MKMaria-Elissavet Koukouli
Maria-Elissavet Koukouli
FGFlorence Goutail
Florence Goutail
JBJérôme Bureau
Jérôme Bureau
CCCathy Clerbaux
Cathy Clerbaux
This paper presents an extensive intercomparison and validation for the ozone (O3) product measured by the two Infrared Atmospheric Sounding Interferometers (IASIs) launched on board the MetOp-A and MetOp-B satellites in 2006 and in 2012 respectively. IASI O3 total columns and vertical profiles obtained from Fast Optimal Retrievals on Layers for IASI (FORLI) v20140922 software (running up until recently) are validated against independent observations during the period 2008–2014 on a global scale. On average for the period 2013–2014, IASI-A and IASI-B total ozone columns (TOCs) retrieved using FORLI are consistent, with IASI-B providing slightly lower values with a global difference of only 0.2 ± 0.8 %. The comparison between IASI-A and IASI-B O3 vertical profiles shows differences within ± 2 % over the entire altitude range. Global validation results for 7 years of IASI TOCs from FORLI against the Global Ozone Monitoring Experiment-2 (GOME-2) launched on board MetOp-A and Brewer–Dobson data show that, on average, IASI overestimates the ultraviolet (UV) data by 5–6 % with the largest differences found in the southern high latitudes. The comparison with UV–visible SAOZ (Système d'Analyse par Observation Zénithale) measurements shows a mean bias between IASI and SAOZ TOCs of 2–4 % in the midlatitudes and tropics and 7 % at the polar circle. Part of the discrepancies found at high latitudes can be attributed to the limited information content in the observations due to low brightness temperatures. The comparison with ozonesonde vertical profiles (limited to 30 km) shows that on average IASI with FORLI processing underestimates O3 by ∼ 5–15 % in the troposphere while it overestimates O3 by ∼ 10–40 % in the stratosphere, depending on the latitude. The largest relative differences are found in the tropical tropopause region; this can be explained by the low O3 amounts leading to large relative errors. In this study, we also evaluate an updated version of FORLI-O3 retrieval software (v20151001), using look-up tables recalculated to cover a larger spectral range using the latest HITRAN spectroscopic database (HITRAN 2012) and implementing numerical corrections. The assessment of the new O3 product with the same set of observations as that used for the validation exercise shows a correction of ∼ 4 % for the TOC positive bias when compared to the UV ground-based and satellite observations, bringing the overall global comparison to ∼ 1–2 % on average. This improvement is mainly associated with a decrease in the retrieved O3 concentration in the middle stratosphere (above 30 hPa/25 km) as shown by the comparison with ozonesonde data.

8 February 2016 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
SHS. Hassinen
S. Hassinen
DBDimitris Balis
Dimitris Balis
HBH. Bauer
H. Bauer
MBM. Begoin
M. Begoin
ADA. Delcloo
A. Delcloo
IZI. Zyrichidou
I. Zyrichidou
The three Global Ozone Monitoring Experiment-2 instruments will provide unique and long data sets for atmospheric research and applications. The complete time period will be 2007–2022, including the period of ozone depletion as well as the beginning of ozone layer recovery. Besides ozone chemistry, the GOME-2 (Global Ozone Monitoring Experiment-2) products are important e.g. for air quality studies, climate modelling, policy monitoring and hazard warnings. The heritage for GOME-2 is in the ERS/GOME and Envisat/SCIAMACHY instruments. The current Level 2 (L2) data cover a wide range of products such as ozone and minor trace gas columns (NO2, BrO, HCHO, H2O, SO2), vertical ozone profiles in high and low spatial resolution, absorbing aerosol indices, surface Lambertian-equivalent reflectivity database, clear-sky and cloud-corrected UV indices and surface UV fields with different weightings and photolysis rates. The Satellite Application Facility on Ozone and Atmospheric Chemistry Monitoring (O3M SAF) processes and disseminates data 24/7. Data quality is guaranteed by the detailed review processes for the algorithms, validation of the products as well as by a continuous quality monitoring of the products and processing. This paper provides an overview of the O3M SAF project background, current status and future plans for the utilisation of the GOME-2 data. An important focus is the provision of summaries of the GOME-2 products including product principles and validation examples together with sample images. Furthermore, this paper collects references to the detailed product algorithm and validation papers.

11 May 2017 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
TDTheano Drosoglou
Theano Drosoglou
ABAlkiviadis F. Bais
Alkiviadis F. Bais
IZIrene Zyrichidou
Irene Zyrichidou
NKNatalia Kouremeti
Natalia Kouremeti
APAnastasia Poupkou
Anastasia Poupkou
DMDimitrios Melas
Dimitrios Melas
One of the main issues arising from the comparison of ground-based and satellite measurements is the difference in spatial representativeness, which for locations with inhomogeneous spatial distribution of pollutants may lead to significant differences between the two data sets. In order to investigate the spatial variability of tropospheric NO2 within a sub-satellite pixel, a campaign which lasted for about 6 months was held in the greater area of Thessaloniki, Greece. Three multi-axial differential optical absorption spectroscopy (MAX-DOAS) systems performed measurements of tropospheric NO2 columns at different sites representative of urban, suburban and rural conditions. The direct comparison of these ground-based measurements with corresponding products from the Ozone Monitoring Instrument onboard NASA's Aura satellite (OMI/Aura) showed good agreement over the rural and suburban areas, while the comparison with the Global Ozone Monitoring Experiment-2 (GOME-2) onboard EUMETSAT's Meteorological Operational satellites' (MetOp-A and MetOp-B) observations is good only over the rural area. GOME-2A and GOME-2B sensors show an average underestimation of tropospheric NO2 over the urban area of about 10.51 ± 8.32 × 1015 and 10.21 ± 8.87 × 1015 molecules cm−2, respectively. The mean difference between ground-based and OMI observations is significantly lower (6.60 ± 5.71 × 1015 molecules cm−2). The differences found in the comparisons of MAX-DOAS data with the different satellite sensors can be attributed to the higher spatial resolution of OMI, as well as the different overpass times and NO2 retrieval algorithms of the satellites. OMI data were adjusted using factors calculated by an air quality modeling tool, consisting of the Weather Research and Forecasting (WRF) mesoscale meteorological model and the Comprehensive Air Quality Model with Extensions (CAMx) multiscale photochemical transport model. This approach resulted in significant improvement of the comparisons over the urban monitoring site. The average difference of OMI observations from MAX-DOAS measurements was reduced to −1.68 ± 5.01 × 1015 molecules cm−2.

12 October 2015 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
MKMaria-Elissavet Koukouli
Maria-Elissavet Koukouli
CLC. Lerot
C. Lerot
JGJ. Granville
J. Granville
FGF. Goutail
F. Goutail
JLJ.‐C. Lambert
J.‐C. Lambert
CZC. Zehner
C. Zehner
The European Space Agency's Ozone Climate Change Initiative (O3‐CCI) project aims at producing and validating a number of high‐quality ozone data products generated from different satellite sensors. For total ozone, the O3‐CCI approach consists of minimizing sources of bias and systematic uncertainties by applying a common retrieval algorithm to all level 1 data sets, in order to enhance the consistency between the level 2 data sets from individual sensors. Here we present the evaluation of the total ozone products from the European sensors Global Ozone Monitoring Experiment (GOME)/ERS‐2, SCIAMACHY/Envisat, and GOME‐2/MetOp‐A produced with the GOME‐type Direct FITting (GODFIT) algorithm v3. Measurements from the three sensors span more than 16 years, from 1996 to 2012. In this work, we present the latest O3‐CCI total ozone validation results using as reference ground‐based measurements from Brewer and Dobson spectrophotometers archived at the World Ozone and UV Data Centre of the World Meteorological Organization as well as from UV‐visible differential optical absorption spectroscopy (DOAS)/Système D′Analyse par Observations Zénithales (SAOZ) instruments from the Network for the Detection of Atmospheric Composition Change. In particular, we investigate possible dependencies in these new GODFIT v3 total ozone data sets with respect to latitude, season, solar zenith angle, and different cloud parameters, using the most adequate type of ground‐based instrument. We show that these three O3‐CCI total ozone data products behave very similarly and are less sensitive to instrumental degradation, mainly as a result of the new reflectance soft‐calibration scheme. The mean bias to the ground‐based observations is found to be within the 1 ± 1% level for all three sensors while the near‐zero decadal stability of the total ozone columns (TOCs) provided by the three European instruments falls well within the 1–3% requirement of the European Space Agency's Ozone Climate Change Initiative project.

12 September 2014 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
NHN. Hao
N. Hao
MKMaria-Elissavet Koukouli
Maria-Elissavet Koukouli
AIA. Inness
A. Inness
PVP. Valks
P. Valks
DLDiego Loyola
Diego Loyola
RSR. J. D. Spurr
R. J. D. Spurr
The two Global Ozone Monitoring Instrument (GOME-2) sensors operated in tandem are flying onboard EUMETSAT's (European Organisation for the Exploitation of Meteorological Satellites) MetOp-A and MetOp-B satellites, launched in October 2006 and September 2012 respectively. This paper presents the operational GOME-2/MetOp-A (GOME-2A) and GOME-2/MetOp-B (GOME-2B) total ozone products provided by the EUMETSAT Satellite Application Facility on Ozone and Atmospheric Chemistry Monitoring (O3M-SAF). These products are generated using the latest version of the GOME Data Processor (GDP version 4.7). The enhancements in GDP 4.7, including the application of Brion–Daumont–Malicet ozone absorption cross sections, are presented here. On a global scale, GOME-2B has the same high accuracy as the corresponding GOME-2A products. There is an excellent agreement between the ozone total columns from the two sensors, with GOME-2B values slightly lower with a mean difference of only 0.55±0.29%. First global validation results for 6 months of GOME-2B total ozone using ground-based measurements show that on average the GOME-2B total ozone data obtained with GDP 4.7 are slightly higher than, both, Dobson observations by about 2.0±1.0% and Brewer observations by about 1.0±0.8%. It is concluded that the total ozone columns (TOCs) provided by GOME-2A and GOME-2B are consistent and may be used simultaneously without introducing systematic effects, which has been illustrated for the Antarctic ozone hole on 18 October 2013. GOME-2A total ozone data have been used operationally in the Copernicus atmospheric service project MACC-II (Monitoring Atmospheric Composition and Climate – Interim Implementation) near-real-time (NRT) system since October 2013. The magnitude of the bias correction needed for assimilating GOME-2A ozone is reduced (to about −6 DU in the global mean) when the GOME-2 ozone retrieval algorithm changed to GDP 4.7.

1 January 2015 in Atmospheric Environment
Verified
Journal Article
Closed access
IZI. Zyrichidou
I. Zyrichidou
MΚM.E. Κoukouli
M.E. Κoukouli
DBDimitris Balis
Dimitris Balis
KMK. Markakis
K. Markakis
APA. Poupkou
A. Poupkou
MRM. van Roozendael
M. van Roozendael