Mengjia Sun

Mengjia Sun

Auto-generated profile, based on publicly available information

Mengjia Sun

Army Med Univ, Mil Med Univ 3, Affiliated Hosp 2, Inst Cardiovasc Dis Peoples Liberat Army, Chongqing, Peoples R China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2023 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
XYXiaowei Ye
Xiaowei Ye
MSMengjia Sun
Mengjia Sun
SYShiyong Yu
Shiyong Yu
JYJie Yang
Jie Yang
ZLZhen Liu
Zhen Liu
LHLan Huang
Lan Huang
Background: Cardiorespiratory fitness plays an important role in coping with hypoxic stress at high altitudes. However, the association of cardiorespiratory fitness with the development of acute mountain sickness (AMS) has not yet been evaluated. Wearable technology devices provide a feasible assessment of cardiorespiratory fitness, which is quantifiable as maximum oxygen consumption (VO2max) and may contribute to AMS prediction. Objective: We aimed to determine the validity of VO2max estimated by the smartwatch test (SWT), which can be self-administered, in order to overcome the limitations of clinical VO2max measurements. We also aimed to evaluate the performance of a VO2max-SWT–based model in predicting susceptibility to AMS. Methods: Both SWT and cardiopulmonary exercise test (CPET) were performed for VO2max measurements in 46 healthy participants at low altitude (300 m) and in 41 of them at high altitude (3900 m). The characteristics of the red blood cells and hemoglobin levels in all the participants were analyzed by routine blood examination before the exercise tests. The Bland-Altman method was used for bias and precision assessment. Multivariate logistic regression was performed to analyze the correlation between AMS and the candidate variables. A receiver operating characteristic curve was used to evaluate the efficacy of VO2max in predicting AMS. Results: VO2max decreased after acute high altitude exposure, as measured by CPET (25.20 [SD 6.46] vs 30.17 [SD 5.01] at low altitude; P<.001) and SWT (26.17 [SD 6.71] vs 31.28 [SD 5.17] at low altitude; P<.001). Both at low and high altitudes, VO2max was slightly overestimated by SWT but had considerable accuracy as the mean absolute percentage error (<7%) and mean absolute error (<2 mL·kg–1·min–1), with a relatively small bias compared with VO2max-CPET. Twenty of the 46 participants developed AMS at 3900 m, and their VO2max was significantly lower than that of those without AMS (CPET: 27.80 [SD 4.55] vs 32.00 [SD 4.64], respectively; P=.004; SWT: 28.00 [IQR 25.25-32.00] vs 32.00 [IQR 30.00-37.00], respectively; P=.001). VO2max-CPET, VO2max-SWT, and red blood cell distribution width-coefficient of variation (RDW-CV) were found to be independent predictors of AMS. To increase the prediction accuracy, we used combination models. The combination of VO2max-SWT and RDW-CV showed the largest area under the curve for all parameters and models, which increased the area under the curve from 0.785 for VO2max-SWT alone to 0.839. Conclusions: Our study demonstrates that the smartwatch device can be a feasible approach for estimating VO2max. In both low and high altitudes, VO2max-SWT showed a systematic bias toward a calibration point, slightly overestimating the proper VO2max when investigated in healthy participants. The SWT-based VO2max at low altitude is an effective indicator of AMS and helps to better identify susceptible individuals following acute high-altitude exposure, particularly by combining the RDW-CV at low altitude. Trial Registration: Chinese Clinical Trial Registry ChiCTR2200059900; https://www.chictr.org.cn/showproj.html?proj=170253

18 March 2021 in Frontiers in Physiology
Verified
Journal Article
Open access
RCRenzheng Chen
Renzheng Chen
JYJie Yang
Jie Yang
CLChuan Liu
Chuan Liu
MSMengjia Sun
Mengjia Sun
JKJingbin Ke
Jingbin Ke
LHLan Huang
Lan Huang
Background: Acute high altitude (HA) exposure elicits blood pressure (BP) responses in most subjects, and some of them suffer from acute mountain sickness (AMS). However, a 24-h ambulatory BP (ABP) change and the correlation with the occurrence of AMS in different sexes are still unclear.Objectives: This prospective study aimed to investigate HA induced BP responses in males and females and the relationship between AMS and 24-h ABP.Methods: Forty-six subjects were matched according to demographic parameters by propensity score matching with a ratio of 1:1. All the subjects were monitored by a 24-h ABP device; the measurement was one period of 24 h BP. 2018 Lake Louise questionnaire was used to evaluate AMS.Results: Both the incidence of AMS (14 [60.9%] vs. 5 [21.7%], P = 0.007) and headache (18 [78.3%] vs. 8 [34.8%], P = 0.003) were higher in females than in males. All subjects showed an elevated BP in the early morning [morning systolic BP (SBP), 114.72 ± 13.57 vs. 120.67 ± 11.10, P = 0.013]. The elevation of morning SBP variation was more significant in females than in males (11.95 ± 13.19 vs. −0.05 ± 14.49, P = 0.005), and a higher morning BP surge increase (4.69 ± 18.09 vs. −9.66 ± 16.96, P = 0.005) was observed after acute HA exposure in the female group. The increase of morning SBP was associated with AMS occurrence (R = 0.662, P < 0.001) and AMS score (R = 0.664, P = 0.001). Among the AMS symptoms, we further revealed that the incidence (R = 0.786, P < 0.001) and the severity of headache (R = 0.864, P < 0.001) are closely correlated to morning SBP.Conclusions: Our study demonstrates that females are more likely to suffer from AMS than males. AMS is closely associated with elevated BP in the early morning period, which may be correlated to higher headache incidence in subjects with higher morning SBP.

1 November 2020 in Biomedicine & Pharmacotherapy
Verified
Journal Article
Open access
MSMengjia Sun
Mengjia Sun
HWHuanjun Wang
Huanjun Wang
LGLili Gong
Lili Gong
DQDongmei Qi
Dongmei Qi
XWXiaoming Wang
Xiaoming Wang
Haiqiang JiangHaiqiang Jiang
Haiqiang Jiang
In the present study, we aimed to use metabolomics platforms to examine circadian-regulated neurotransmitters across a 24-h day and the effects of Uncaria administration on daily rhythmicity in order to establish a strategy for evaluating the spatiotemporal efficacy evaluation strategy of Uncaria. By using targeted ultrahigh performance liquid chromatography-mass spectrometry metabolomics, we quantified 32 neurotransmitter metabolites every 4 h over 24 h. To assess 24-h metabolite rhythmicity, we performed cosinor analysis. The expression of hypothalamic rhythm genes was detected by reverse transcription polymerase chain reaction (RT-PCR). Data revealed circadian loss of many neurotransmitters during the entire circadian cycle in the serum of group M, indicating that hypertension causes circadian rhythm disorders. Cosinor analysis of the rhythmic oscillations of the levels of 32 neurotransmitters in the three groups showed that the metabolite rhythms peaked at approximately the same time of day (ZT4 and ZT16). Moreover, the amplitudes of the metabolite rhythms were altered. After treatment with Uncaria, the amplitudes of 13 neurotransmitters reverted to normal. The change trends in the hypothalamic rhythm genes confirmed the rhythm changes in neurotransmitters. Collectively, a novel pharmacodynamic evaluation strategy was established to dynamically observe the holistic effects of Uncaria on 32 circulating neurotransmitters within 24 h from the perspective of time dimension.

9 October 2022 in JMIR Preprints
Verified
Preprint
Open access
XYXiaowei Ye
Xiaowei Ye
MSMengjia Sun
Mengjia Sun
SYShiyong Yu
Shiyong Yu
JYJie Yang
Jie Yang
ZLZhen Liu
Zhen Liu
LHLan Huang
Lan Huang
BACKGROUND Cardiorespiratory fitness plays an important role in coping with hypoxic stress at high altitudes. However, the association of cardiorespiratory fitness with the development of acute mountain sickness (AMS) has not yet been evaluated. Wearable technology devices provide a feasible assessment of cardiorespiratory fitness, which is quantifiable as maximum oxygen consumption (VO2max) and may contribute to AMS prediction. OBJECTIVE We aimed to determine the validity of VO2max estimated by the smartwatch test (SWT), which can be self-administered, in order to overcome the limitations of clinical VO2max measurements. We also aimed to evaluate the performance of a VO2max-SWT–based model in predicting susceptibility to AMS. METHODS Both SWT and cardiopulmonary exercise test (CPET) were performed for VO2max measurements in 46 healthy participants at low altitude (300 m) and in 41 of them at high altitude (3900 m). The characteristics of the red blood cells and hemoglobin levels in all the participants were analyzed by routine blood examination before the exercise tests. The Bland-Altman method was used for bias and precision assessment. Multivariate logistic regression was performed to analyze the correlation between AMS and the candidate variables. A receiver operating characteristic curve was used to evaluate the efficacy of VO2max in predicting AMS. RESULTS VO2max decreased after acute high altitude exposure, as measured by CPET (25.20 [SD 6.46] vs 30.17 [SD 5.01] at low altitude; P<.001) and SWT (26.17 [SD 6.71] vs 31.28 [SD 5.17] at low altitude; P<.001). Both at low and high altitudes, VO2max was slightly overestimated by SWT but had considerable accuracy as the mean absolute percentage error (<7%) and mean absolute error (<2 mL·kg–1·min–1), with a relatively small bias compared with VO2max-CPET. Twenty of the 46 participants developed AMS at 3900 m, and their VO2max was significantly lower than that of those without AMS (CPET: 27.80 [SD 4.55] vs 32.00 [SD 4.64], respectively; P=.004; SWT: 28.00 [IQR 25.25-32.00] vs 32.00 [IQR 30.00-37.00], respectively; P=.001). VO2max-CPET, VO2max-SWT, and red blood cell distribution width-coefficient of variation (RDW-CV) were found to be independent predictors of AMS. To increase the prediction accuracy, we used combination models. The combination of VO2max-SWT and RDW-CV showed the largest area under the curve for all parameters and models, which increased the area under the curve from 0.785 for VO2max-SWT alone to 0.839. CONCLUSIONS Our study demonstrates that the smartwatch device can be a feasible approach for estimating VO2max. In both low and high altitudes, VO2max-SWT showed a systematic bias toward a calibration point, slightly overestimating the proper VO2max when investigated in healthy participants. The SWT-based VO2max at low altitude is an effective indicator of AMS and helps to better identify susceptible individuals following acute high-altitude exposure, particularly by combining the RDW-CV at low altitude. CLINICALTRIAL Chinese Clinical Trial Registry ChiCTR2200059900; https://www.chictr.org.cn/showproj.html?proj=170253