The disturbance voltage of voltage-source inverter operation exerts significant influences on the accuracy of motor parameter identification. In this paper, an accurate model is established for estimating the disturbance voltage that includes current harmonics and their derivative. The conclusion is drawn that the derivative of the d -axis current harmonics plays a major role in causing estimation error of the disturbance voltage. Based on this, two methods are proposed to reduce the estimation error of the disturbance voltage. One employs an iterative learning controller in the d-axis current control loop to suppress the harmonics of d-axis current, thus reducing their influence on the estimation of the disturbance voltage. The second estimates the disturbance voltage on the basis of the average value of the variables in q-axis equation of the motor, so that the estimation result is immune to current harmonics. Motor parameter identification accuracy is consequently improved by both.
24 September 2024 in IEEE Transactions on Industrial Electronics
To reduce the output current distortion, this article proposes a novel space vector overmodulation strategy for indirect matrix converter (IMC) in the overmodulation region I. First, the effect of error voltage vector on current harmonics based on minimum-phase-error (MPE) overmodulation strategy is analyzed. According to the characteristics analysis of current ripple, the proposed overmodulation strategy, without changing the selection or duty ratio of the two active voltage and current vectors, rearranges the action time and position of the zero-voltage vector to make the actual current approach the reference current value and reduces the output current ripple. Moreover, the zero-voltage vector is only used under the large current vector, which can reduce the switching times. The efficiency is improved due to the reduction of output current ripple and switching times. Finally, the effectiveness of the proposed overmodulation strategy is verified through experiments.
1 January 2020 in IEEE Transactions on Industrial Electronics
A novel direct torque control (DTC) using dynamic sector boundary is proposed for a matrix converter (MC) fed permanent magnet synchronous motor (PMSM) drive system in order to minimize common-mode voltage of the system, based on the fact that rotating vectors produce zero common-mode voltage. According to the feature of rotating vectors that their relative position varies with the varying of the phase of input voltage, the vector plane is divided into sectors with dynamic boundaries, and the rotating vectors are re-denoted dynamically. A novel switching table and a mapping table of rotating vectors are established according to the control effects of each rotating vector in each sector, and direct torque control with only rotating vectors is achieved. Experiments with a 2-kW prototype are carried out. The results show that adequate dynamic performance and considerable common-mode voltage reduction is achieved by using the novel MC-DTC.
29 May 2020 in IEEE Transactions on Power Electronics
A novel direct torque control (DTC) is proposed for a matrix converter (MC) fed permanent magnet synchronous motor (PMSM) drive system in order to minimize common-mode voltage. Rotating vectors are utilized due to the fact that they produce zero common-mode voltage. As the distribution of rotating vectors varies with the input voltage phase, the DTC switching table has to vary for numerous different values of input voltage phase, which will lead to a highly complicated control structure. The merit of the proposed MC-DTC method is that it provides a feasible and fairly simple way to establish a multi-dimensional switching table for rotating vectors. To fulfill that, six specific values of input voltage phase are selected to approximately represent the whole range of (0, 2π), and the corresponding six switching tables are combined as the multi-dimensional switching table. Experiments are carried out, and the results show that adequate dynamic and steady state performance and considerable common-mode voltage reduction is achieved by using the proposed MC-DTC.
28 September 2022 in IEEE Transactions on Power Electronics
The traditional direct torque control (DTC) of two-level voltage source inverter-fed motor system can achieve evident reduction of common-mode voltage (CMV) if zero vectors are not used, as the amplitude of the CMV of the zero vector is much larger than that of the active vector. However, due to the influence of dead-time effect, zero vectors can still be generated during inverter commutation, resulting in CMV spikes. To eliminate the CMV spikes caused by dead-time effect, a novel DTC strategy is proposed in this article. Through the analysis of the voltage vector during the dead-time of the commutation process, the process of looking up the DTC switching table is modified, and a transient vector is inserted when necessary, so that no zero vector is generated during commutation. The proposed DTC strategy eliminates CMV spikes in a look-up table way, so that the simple control structure of traditional DTC is maintained, while neither modification of hardware circuit nor detection of current polarity are required. Experiments verified the effectiveness of the proposed strategy.
23 October 2020 in IEEE Transactions on Power Electronics
Matrix converter rotating vectors (RVs) have the natural advantage of zero common-mode voltage (CMV). If the RVs alone are employed to drive the motor, ideal minimization of CMV can be achieved. However, it is proven in existing literature that the maximum voltage transfer ratio (VTR) is only 0.5 with space vector modulation using only RVs, which greatly limits the practical application value of the RV. This article quantitatively analyzes the maximum VTR under an existing direct torque control using only RVs, and the result is 0.833, which is much greater than 0.5. Experiments are carried out to verify this conclusion. This article reveals the potential of RVs, and hence promotes further research on the CMV minimization strategies without sacrificing performance like maximum.