Shoufeng Jin

Shoufeng Jin

Auto-generated profile, based on publicly available information

Shoufeng Jin

State Key Laboratory of Electrical Insulation and Power Equipment Xi'an Jiaotong University Xi'an China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
SJShoufeng Jin
Shoufeng Jin
TXTao Xie
Tao Xie
QWQingyu Wang
Qingyu Wang
TRTing Ren
Ting Ren
PLPeng Liu
Peng Liu
ZPZongren Peng
Zongren Peng
As the key component of the conductor of the gas-insulated power transmission equipment, the electrical connection structure bears high current, high stress and high temperature for a long time. Electrical contact failures become an important issue, while it’s failure characteristics and mechanisms are ambiguous so far. In this paper, based on complex electrical connection structures of gas-insulated transmission line (GIL), equivalent tests were conducted on the contact failure characteristics of such structure. Result shows that poor contact of the such electrical connection structure will cause two types of situations: micro-gap discharge and contact overheating. The causes of both are different. Firstly, micro slip is a kind of cause of discharge faults despite the separation gap is small. The current transfer area (b) of such contact structure is the main position where the arc starts. The contact stability at that location should be fully considered in the layout of such electrical connection structure. Secondly, combined with the surface morphology and element distribution, the mechanism of contact discharge and the source of metal particles are further explained by the occurrence of coating peeling and material transfer behavior. Finally, the difference in contact state is the main reason for a few contacts overheating. There is a significant temperature difference between contacts in different contact state. The temperature rises nonlinearly with the increase of the current under the condition of uneven current carrying. The above research can provide a practical basis for fault analysis and prevention of such electric contact structures in the UHV gas-insulated power transmission equipment.

1 September 2019
Verified
Conference Paper
Closed access
HTHuidong Tian
Huidong Tian
ZWZehua Wu
Zehua Wu
QWQingyu Wang
Qingyu Wang
SJShoufeng Jin
Shoufeng Jin
PLPeng Liu
Peng Liu
ZPZongren Peng
Zongren Peng

6 October 2019 in Elektronika ir Elektrotechnika
Verified
Journal Article
Open access
PDF file
SJShoufeng Jin
Shoufeng Jin
QLQiangqiang Lin
Qiangqiang Lin
JYJian Yang
Jian Yang
YBYu Bie
Yu Bie
MTMingrui Tian
Mingrui Tian
ZLZhixiong Li
Zhixiong Li
An improved SURF (Speeded-Up Robust Feature) algorithm is proposed to deal with the time-consuming and low precision of positioning of industrial robot. Hessian matrix determinant is used to extract feature points from the target image and a multi-scale spatial pyramid is constructed. The location and scale value of feature points are determined by neighbourhood non-maximum suppression method. The direction of feature points is defined as directional feature descriptors by the binary robust independent elementary feature (BRIEF). The progressive sample consensus (PROSAC) is used to carry out second precise matching and remove mismatching points based on the Hamming distance. Then, an affine transformation model is established to describe the relationship between the template and target images. Centroid coordinates of the target can be obtained based on the affine transformation. Comparative tests were carried out to demonstrate that the proposed method can effectively improve the recognition rate and positioning accuracy of the industrial robots. The average time consuming is less than 0.2 s, the matching accuracy is 96 %, and the positioning error of the robot is less than 1.5 mm. Therefore, the proposed method has practical application importance.

24 May 2024 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
QWQingyu Wang
Qingyu Wang
XZXiaoyu Zhou
Xiaoyu Zhou
WYWei Yang
Wei Yang
DHDi Hu
Di Hu
SJShoufeng Jin
Shoufeng Jin
ZPZongren Peng
Zongren Peng
The contact finger electrical connection structure is a crucial component of high voltage bushings, and its safety and reliability directly impact the operational stability of the bushing. To investigate electrical contact performance of the contact finger under eccentric conditions, a three‐dimensional electrical, thermal, and force multi‐physics coupling calculation model was established. Additionally, a test platform was constructed to measure electrical contact characteristics of the contact finger. The contact characteristics of the contact finger when the male head was axially deflected and radially offset compared to the female head were obtained. The research findings indicate when the male head deflects axially, the contact force changes of the contact finger blades on both sides are opposite. Moreover, as the axial deflection angle of the male head increases, the resistance of the electrical connection structure shows a rising‐slow decreasing‐fluctuating trend. The resistance is highest at 3°, with a resistance increase rate of 7.35%. Furthermore, the resistance of the electrical connection structure varies with the radial offset of the male head, following a power function. Contact failure occurs when the radial offset is 1.31 mm, and the resistance increase rate reaches 24.9% at a radial offset of 1.58 mm.

7 April 2021 in DEStech Transactions on Materials Science and Engineering
Verified
Journal Article
Open access
DYDongfeng Yang
Dongfeng Yang
SJShoufeng Jin
Shoufeng Jin
XZXiao Zhang
Xiao Zhang
PKPengtao Ku
Pengtao Ku