Giles N. Cattermole

Giles N. Cattermole

Auto-generated profile, based on publicly available information

Giles N. Cattermole

Emergency Department, Princess Royal University Hospital, London, UK

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2017 in Physiological Reports
Verified
Journal Article
Open access
PDF file
GCGiles N. Cattermole
Giles N. Cattermole
PLP. Y. Mia Leung
P. Y. Mia Leung
GHGrace Y. L. Ho
Grace Y. L. Ho
PLPeach W. S. Lau
Peach W. S. Lau
CCCangel P. Y. Chan
Cangel P. Y. Chan
TRTimothy H. Rainer
Timothy H. Rainer
The ultrasonic cardiac output monitor (USCOM) is a noninvasive transcutaneous continuous wave Doppler method for assessing hemodynamics. There are no published reference ranges for normal values in adults (aged 18–60 years) for this device. This study aimed to (1) measure cardiovascular indices using USCOM in healthy adults aged 18–60 years; (2) combine these data with those for healthy children (aged 0–12), adolescents (aged 12–18), and the elderly (aged over 60) from our previously published studies in order to present normal ranges for all ages, and (3) establish normal ranges of USCOM‐derived variables according to both weight and age. This was a population‐based cross‐sectional observational study of healthy Chinese subjects aged 0.5–89 years in Hong Kong. USCOM scans were performed on all subjects, to produce measurements including stroke volume, cardiac output, and systemic vascular resistance. Data from previously published studies (children, adolescents, and the elderly) were included. Normal ranges were defined as lying between the 2.5th and 97.5th percentiles. A total of 2218 subjects were studied (mean age = 16.4, range = 0.5–89; 52% male). From previous studies, 1197 children (aged 0–12, 55% male), 590 adolescents (aged 12–18, 49% male), and 77 elderly (aged 60–89, 55% male) were included. New data were collected from 354 adults aged 18–60 (47% male). Normal ranges are presented according to age and weight. We present comprehensive normal ranges for hemodynamic parameters obtained with USCOM in healthy subjects of all ages from infancy to the elderly.

1 September 2010 in Critical Care Medicine
Verified
Journal Article
Closed access
GCGiles N. Bm Cattermole
Giles N. Bm Cattermole
PLP. Y. Mia BMedSc Leung
P. Y. Mia BMedSc Leung
PMPaulina S. K. Bsc Mak
Paulina S. K. Bsc Mak
SCStewart S. W. Mb Bs Chan
Stewart S. W. Mb Bs Chan
CGColin Graham
Colin Graham
TRTimothy Hudson Rainer
Timothy Hudson Rainer
Objective: The Ultrasonic Cardiac Output Monitor is a noninvasive method of hemodynamic assessment and monitoring in critically ill patients. There are no published reference ranges for normal values in children for this device. This study aimed to establish normal ranges for cardiovascular indices measured using Ultrasonic Cardiac Output Monitor in children aged 0–12 yrs old and to assess interobserver reliability. Design: This was a population-based cross-sectional observational study. Setting: Schools and kindergartens in Hong Kong. Subjects: Chinese children aged up to 12 yrs old. Interventions: Two operators performed Ultrasonic Cardiac Output Monitor scans on each child together with standard oscillometric measurement of blood pressure and heart rate. Software intrinsic to the Ultrasonic Cardiac Output Monitor device produces values for stroke volume, cardiac output, and systemic vascular resistance. For each parameter, normal ranges were defined as lying between the 2.5th and 97.5th percentiles. Interobserver reliability was assessed with Bland-Altman plots, coefficients of variation, and intraclass correlation. Measurements and Main Results: A total of 1,197 Chinese children (55% boys) were scanned. Normal ranges of values for cardiac output, stroke volume, and systemic vascular resistance indices are presented. Interobserver reliability for Ultrasonic Cardiac Output Monitor was superior to that for standard blood pressure and heart rate measurement. Conclusions: This large study presents normal values for cardiovascular indices in children using the Ultrasonic Cardiac Output Monitor with good interobserver reliability.

1 September 2010 in Resuscitation
Verified
Journal Article
Closed access
GCG.N. Cattermole
G.N. Cattermole
PLP.Y.M. Leung
P.Y.M. Leung
PMP.S.K. Mak
P.S.K. Mak
CGColin Graham
Colin Graham
TRTimothy Hudson Rainer
Timothy Hudson Rainer

1 May 2014 in Injury
Verified
Journal Article
Closed access
TRTimothy Hudson Rainer
Timothy Hudson Rainer
JYJ.H.H. Yeung
J.H.H. Yeung
SCS.K.C. Cheung
S.K.C. Cheung
YYY.K.Y. Yuen
Y.K.Y. Yuen
WPW.S. Poon
W.S. Poon
CGColin Graham
Colin Graham

19 December 2016 in Emergency Medicine Journal
Verified
Journal Article
Open access
PDF file
GCGiles N Cattermole
Giles N Cattermole
CGColin Graham
Colin Graham
TRTimothy H Rainer
Timothy H Rainer
Objectives Many drug and fluid regimens in emergency medicine are weight dependent in adults, but no standard adult weight estimation tools exist. Paediatric weight is often estimated in emergency situations using methods based on age or height when direct measurement is not possible, and recently, methods based on mid-arm circumference (MAC) have also been developed. The aim of this study was to derive and validate an accurate MAC-based method for weight estimation for use in all age groups. Methods Data were obtained from the US National Health and Nutrition Examination Survey (NHANES). MAC-based methods of weight estimation were derived in 8498 subjects (5595 adults aged 16–80 years, 2903 children aged 1–15.9 years) from the NHANES 2011–2012 dataset, using linear regression. NHANES 2009–2010 was used for validation in 9022 subjects (6049 adults aged 16–79 years, 2973 children aged 1–15.9 years). Results A simplified method of MAC-based weight estimation was derived from linear regression equation: weight in kg=4×MAC (in cm)—50. On validation, results in children aged 1–10.9 years were poor. In adults and children aged 11–15.9 years, over 60%, 90% and 98% of estimates fell, respectively, within 10%, 20% and 30% of actual weights when using the simplified formula. Conclusions In this description of a method for estimating weight in adults, we have derived and validated a simplified formula that is at least as precise in adults and adolescents as commonly used paediatric weight estimation tools in children.

1 September 2009 in Resuscitation
Verified
Journal Article
Closed access
GCGiles N. Cattermole
Giles N. Cattermole
SMS.K. Paulina Mak
S.K. Paulina Mak
CLC.H. Elizabeth Liow
C.H. Elizabeth Liow
MHMan fung HO
Man fung HO
KHKin Yee Grace Hung
Kin Yee Grace Hung
TRTimothy Hudson Rainer
Timothy Hudson Rainer