24 June 2021 in IEEE Transactions on Plasma Science
Free metal particle can affect surface charge accumulation on epoxy insulator installed in gas-insulated transmission line (GIL) or gas-insulated switchgear (GIS), which results in reduction of surface flashover voltage thus threatening the safe operation of the power equipment. This article reports on the charge accumulation behavior on a real size epoxy insulator with bouncing metal particle under DC voltage. A coaxial electrode system was designed for the test under -30 kV, a metal particle-launching system was employed to inject the bouncing linear particle to the insulator surface. The charge distribution was measured by a Kelvin-type probe, and the influence of the particle on the charge accumulation was analyzed with the help of electric field simulation. The results showed that there were mainly two moving patterns of the bouncing particle: the charges were accumulated with speckle shape and the charged particle that hit the edge of electrode had more remarkable influence on the charge accumulation than other particles. It is suggested that the charge distribution feature is dependent upon the collision point and the trajectory of the bouncing particle.
23 April 2021 in IEEE Transactions on Plasma Science
Surface charge accumulation on epoxy insulator installed in gas-insulated transmission line (GIL) and gas-insulated switchgear (GIS) has been recognized as a crucial factor for electric field distortion that results in the reduction of surface flashover voltage. This article reports on the gaseous ionization dependence of the charge accumulation pattern on a real-size epoxy insulator with multiarc surface profile by using various gas atmospheres. A coaxial electrode system was designed to investigate the charging behavior under dc voltages of -10, -20, and -30 kV. The insulator and electrodes were placed in a metal-enclosed test chamber, which was filled with 0.1 MPa air or 0.4 MPa SF 6 /N 2 mixture to estimate the influence of the gas atmosphere on the charge accumulation behavior by a Kelvin-type probe. The accumulation mechanism and the electric field distortion induced by the charges were demonstrated based on numerical simulation. The results indicated that positive charges were accumulated in the shape of speckle on insulator surface in air, whereas both positive and negative charges were accumulated in SF 6 /N 2 mixture and positive charge speckles appeared in SF 6 /N 2 mixture only when the voltage raised up to -30 kV. It is considered that the charge accumulation behavior is determined by the competition result among the bulk, the gas and the surface conductions. As compared with the case in air, gaseous ionization in SF 6 /N 2 mixture is more difficult to occur, which leads to the obvious difference in the charge accumulation pattern.
18 December 2019 in IEEE Access
Surface charge accumulation under DC stress is a critical factor in reducing the insulation performance of epoxy-based nanocomposite. Surface coating has been used to inhibit the charge accumulation, but the inhibition mechanism of the coating material is still unclear. In this paper, graphene oxide (GO) and silicon carbide (SiC) have been selected as fillers to prepare the coating material with epoxy as the base material. The role of GO on surface charge inhibition performance of epoxy/SiC coating has been estimated. The test results showed that the charge inhibition performance increased with the growth of nano-SiC content from 1 wt% to 5 wt% in the epoxy/SiC coating. As regards the epoxy/(SiC+GO) coating, the charge inhibition performance reduced as the SiC content increased. It is suggested that the charge inhibition performance of epoxy/SiC coating can be improved with a low content addition of GO. The variation of trap distribution in the coating material caused by the GO should be responsible for the enhanced charge inhibition behavior.