2 June 2025 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
SMSantiago Martinez-Correa
In imaging the neonatal brain, overcoming the diffraction limit to conventional ultrasound is required to achieve images of sufficient spatial resolution. Super-resolution imaging uses ultrasound localization microscopy to image inert microbubble contrast at high frame rates, allowing exquisite detail and flow information on intracranial vessels. However, this is a mainly research-based modality. In contrast, advanced Doppler techniques, which do not require contrast, offer flow imaging far better than that of conventional Doppler, and are readily available in the clinical setting. We discuss the pros and cons of both modalities, and the promising applications of both in the clinical setting with a series of case-examples.
27 October 2022 in IEEE Transactions on Biomedical Engineering
Objective: Doppler ultrasound (DU) is used to detect venous gas emboli (VGE) post dive as a marker of decompression stress for diving physiology research as well as new decompression procedure validation to minimize decompression sickness risk. In this paper, we propose the first deep learning model for VGE grading in DU audio recordings. Methods: A database of real-world data was assembled and labeled for the purpose of developing the algorithm, totaling 274 recordings comprising both subclavian and precordial measurements. Synthetic data was also generated by acquiring baseline DU signals from human volunteers and superimposing laboratory-acquired DU signals of bubbles flowing in a tissue mimicking material. A novel squeeze-and-excitation deep learning model was designed to effectively classify recordings on the 5-class Spencer scoring system used by trained human raters. Results: On the real-data test set, we show that synthetic data pretraining achieves average ordinal accuracy of 84.9% for precordial and 90.4% for subclavian DU which is a 24.6% and 26.2% increase over training with real-data and time-series augmentation only. The weighted kappa coefficients of agreement between the model and human ground truth were 0.74 and 0.69 for precordial and subclavian respectively, indicating substantial agreement similar to human inter-rater agreement for this type of data. Conclusion: The present work demonstrates the first application of deep-learning for DU VGE grading using a combination of synthetic and real-world data. Significance: The proposed method can contribute to accelerating DU analysis for decompression research.
27 April 2023 in PLOS ONE
Doppler ultrasound (DU) measurements are used to detect and evaluate venous gas emboli (VGE) formed after decompression. Automated methodologies for assessing VGE presence using signal processing have been developed on varying real-world datasets of limited size and without ground truth values preventing objective evaluation. We develop and report a method to generate synthetic post-dive data using DU signals collected in both precordium and subclavian vein with varying degrees of bubbling matching field-standard grading metrics. This method is adaptable, modifiable, and reproducible, allowing for researchers to tune the produced dataset for their desired purpose. We provide the baseline Doppler recordings and code required to generate synthetic data for researchers to reproduce our work and improve upon it. We also provide a set of pre-made synthetic post-dive DU data spanning six scenarios representing the Spencer and Kisman-Masurel (KM) grading scales as well as precordial and subclavian DU recordings. By providing a method for synthetic post-dive DU data generation, we aim to improve and accelerate the development of signal processing techniques for VGE analysis in Doppler ultrasound.