24 September 2022 in HAND
Background: Traumatic finger amputations are a common and well-known hand injury, yet there are few studies addressing long-term epidemiologic data and associated mechanisms of injury. This paper aims to use a large national database to identify the relationship of patient demographics and mechanism of injury in finger amputations. Methods: The National Electronic Injury Surveillance System (NEISS) was queried for finger amputations in the United States from 2010 to 2019. Patient demographic information was collected and analyzed by gender, race, age, and further statistical analysis was performed to determine correlations with consumer products. Results: Finger amputations accounted for an estimated 234,304 emergency department visits from 2010 to 2019. Most of the patients were male (79%) and identified as white (46.2%). The most commonly implicated products overall were power saws and related power tools, followed by doors and then lawn mowers. A bimodal age incidence was observed with the highest incidence rates occurring in children ages 0 to 4, followed by a second peak incidence rate in the adults ages 65 to 74. The most common mechanisms of injury were found to differ in patients less than 19 and those 20 and over. Conclusion: Traumatic finger amputations have a bimodal incidence with changing epidemiology and mechanism of injury with age. The first peak occurs from ages 0 to 4, involves predominantly doors, and has a male to female ratio of 1.30. The second peak occurs from ages 65 to 74, involves mostly power saws, and has a male to female ratio of 6.68. Level of Evidence: Prognostic, Level IV
14 March 2022 in Seminars in Arthroplasty: JSES
Introduction: Advancements in technique and devices and a better understanding of forearm kinematics have contributed to the improvement in outcomes following radial head arthroplasty (RHA). The results of RHA depend on the inherent variability of the proximal radial anatomy and on the subsequent difficulties in attaining anatomic positioning of the prosthesis. A monobloc prosthesis with an anatomical head that is aligned with the patient’s axis of forearm rotation has been recently introduced. We report the clinical and radiographic outcomes for patients across multiple centers who received this radial head implant with a minimum of 2 years follow-up. Methods: This was a multi-institution retrospective follow-up including 6 centers and multiple surgeons. A total of 114 cases were performed prior to July 20, 2019, of which 52 (46%) responded to request for follow-up. Data collected included Mayo Elbow Performance Score (MEPS), Disabilities of the Arm, Shoulder and Hand scores (DASH), visual analog scale for pain (VAS), major complications and reoperations. Major complications were defined as any prosthesis related event which may or may not have required reoperation Results: Mean MEPS was 87.0 (range 55 - 100) with 46% (24/52) scoring a 100. Mean VAS for pain at rest was 0.9 (range 0 - 10) and mean VAS for pain while unscrewing a bottle cap was 1.9 (range 0 - 10). Mean DASH was 19.6 (range 0 - 88.6). We recorded a total of 4 major complications, 3 of which required reoperations, for a rate of 7.6% and 5.7% respectively. Discussion: The current results, collected from 6 institutions and multiple surgeons, are comparable to those of other similar series for radial head prostheses. Our series had lower rates of complications and reoperations. There were no cases of stem loosening. The alignment of the radial head to the forearm axis of rotation may restore forearm kinematics. This design may lead to radiocapitellar contact pressures that are more physiologic in load transmission.
21 September 2021 in HAND
To identify the rate of 30-day complications after primary repair of upper extremity peripheral nerve injuries, associated diagnoses, and postoperative complication rate. The American College of Surgeons National Surgical Quality Improvement Program database was reviewed from 2010 to 2016. Current Procedural Terminology codes consistent with primary nerve repair of the upper extremity were identified and included in the analysis. Patient demographics, comorbidities, type of procedure (elective/emergent), wound class, operative time, and 30-day complications were recorded. Patients with isolated upper extremity nerve injuries (isolated) were compared with those with peripheral nerve injuries in addition to bone, tendon, or soft tissue injuries (multiple). In all, 785 patients were identified as having upper extremity nerve repairs (0.16%). Of them, 64% were men and 36% were women; the average patient age was 40 years. The most common indication for surgery was injury to the digits (54% of cases). Thirty-day adverse events occurred in 3% of all cases. Isolated nerve injury occurred in 43% of patients, whereas 57% had additional injuries. The multiple injury group had a significantly higher complication rate compared with the isolated group (1% vs 4.5%) (P = .007). Repair of tendon at forearm or wrist was the most common concurrent procedure performed. Thirty-day complications among upper extremity peripheral nerve injuries are low, accounting for 3% of cases. Return to the operating room accounted for nearly half of all complications. Patients in the multiple injury group accounted for more than half of these and had a significantly higher complication rate compared with patients with isolated nerve injuries.