Hung-Ta Wo

Hung-Ta Wo

Auto-generated profile, based on publicly available information

Hung-Ta Wo

Department of Internal Medicine, Division of Cardiology, Chang Gung Memorial Hospital, Linkou, Taoyuan, Taiwan

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 January 2021 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
PDF file
YHYi-Ting Hwang
Yi-Ting Hwang
HLHui-Ling Lee
Hui-Ling Lee
CLCheng-Hui Lu
Cheng-Hui Lu
PCPo-Cheng Chang
Po-Cheng Chang
HWHung-Ta Wo
Hung-Ta Wo
CCChung-Chuan Chou
Chung-Chuan Chou
Aims: Curved M-mode images of global strain (GS) and strain rate (GSR) provide sufficiently detailed spatiotemporal information of deformation mechanics. This study investigated whether a deep convolutional neural network (CNN) could accurately classify these images in patients with atrial fibrillation (AF) who underwent radiofrequency catheter ablation (RFCA) with different outcomes.Methods and Results: We retrospectively evaluated 606 consecutive patients who underwent RFCA for drug-refractory AF. Patients were divided into AF-free (n = 443) and AF-recurrent (n = 163) groups. Transthoracic echocardiography was performed within 24 h after RFCA. Left atrial curved M-mode speckle-tracking images were acquired from randomly selected 163 patients in AF-free group and 163 patients in AF-recurrent group as the dataset for deep CNN modeling. We used the ReLu activation function and repeatedly performed CNN model for 32 times to evaluate the stability of hyperparameters. Logistic regression models with the left atrial dimension, emptying fraction, and peak systolic GS as predictor variables were used for comparisons. Images from the apical 2-chamber (2-C) and 4-chamber (4-C) views had distinct features, leading to different CNN performance between settings; of them, the “4-C GS+4-C GSR” setting provided the highest performance index values. All four predictor variables used for logistic regression modeling were significant; however, none of them, individually or in any combined form, could outperform the optimal CNN model.Conclusion: The novel approach using deep CNNs for learning features of left atrial curved M-mode speckle-tracking images seems to be optimal for classifying outcome status after AF ablation.

16 April 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
PCPo-Cheng Chang
Po-Cheng Chang
HLHui-Ling Lee
Hui-Ling Lee
HWHung-Ta Wo
Hung-Ta Wo
HLHao-Tien Liu
Hao-Tien Liu
MWMing-Shien Wen
Ming-Shien Wen
CCChung-Chuan Chou
Chung-Chuan Chou
Background: The VICTORIA trial demonstrated a significant decrease in cardiovascular events through vericiguat therapy. This study aimed to assess the potential mechanisms responsible for the reduction of cardiovascular events with vericiguat therapy in a rabbit model of myocardial infarction (MI). Methods: A chronic MI rabbit model was created through coronary artery ligation. Following 4 weeks, the hearts were harvested and Langendorff perfused. Subsequently, electrophysiological examinations and dual voltage-calcium optical mapping studies were conducted at baseline and after administration of vericiguat at a dose of 5 μmol/L. Results: Acute vericiguat therapy demonstrated a significant reduction in premature ventricular beat burden and effectively suppressed ventricular arrhythmic inducibility. The electrophysiological influences of vericiguat therapy included an increased ventricular effective refractory period, prolonged action potential duration, and accelerated intracellular calcium (Cai) homeostasis, leading to the suppression of action potential and Cai alternans. The pacing-induced ventricular arrhythmias exhibited a reentrant pattern, attributed to fixed or functional conduction block in the peri-infarct zone. Vericiguat therapy effectively mitigated the formation of cardiac alternans as well as the development of reentrant impulses, providing additional anti-arrhythmic benefits. Conclusions: In the MI rabbit model, vericiguat therapy demonstrates anti-ventricular arrhythmia effects. The vericiguat therapy reduces ventricular ectopic beats, inhibiting the initiation of ventricular arrhythmias. Furthermore, the therapy successfully suppresses cardiac alternans, preventing conduction block and, consequently, the formation of reentry circuits.

1 January 2015 in BioMed Research International
Verified
Journal Article
Open access
PDF file
CCChung-Chuan Chou
Chung-Chuan Chou
HLHui-Ling Lee
Hui-Ling Lee
PCPo-Cheng Chang
Po-Cheng Chang
HWHung-Ta Wo
Hung-Ta Wo
MWMing-Shien Wen
Ming-Shien Wen
SYSan-Jou Yeh
San-Jou Yeh
Dantrolene was reported to suppress ventricular fibrillation (VF) in failing hearts with acute myocardial infarction, but its antiarrhythmic efficacy in regional ischemia-reperfusion (IR) hearts remains debatable. Heart failure (HF) was induced by right ventricular pacing. The IR rabbit model was created by coronary artery ligation for 30 min, followed by reperfusion for 15 min in vivo in both HF and non-HF groups (n= 9 in each group). Simultaneous voltage and intracellular Ca2+(Cai) optical mapping was then performed in isolated Langendorff-perfused hearts. Electrophysiological studies were conducted and VF inducibility was evaluated by dynamic pacing. Dantrolene (10 μM) was administered after baseline studies. The HF group had a higher VF inducibility than the control group. Dantrolene had both antiarrhythmic (prolonged action potential duration (APD) and effective refractory period) and proarrhythmic effects (slowed conduction velocity, steepened APD restitution slope, and enhanced arrhythmogenic alternans induction) but had no significant effects on ventricular premature beat (VPB) suppression and VF inducibility in both groups. A higher VF conversion rate in the non-HF group was likely due to greater APD prolonging effects in smaller hearts compared to the HF group. The lack of significant effects on VPB suppression by dantrolene suggests that triggered activity might not be the dominant mechanism responsible for VPB induction in the IR model.