Shida Kuang

Shida Kuang

Auto-generated profile, based on publicly available information

Shida Kuang

Department of Orthopaedics, Xiangya Hospital, Central South University, Changsha, Hunan Province, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2022 in BioMed Research International
Verified
Journal Article
Open access
PDF file
WLWeijie Liu
Weijie Liu
HWHaoChen Wang
HaoChen Wang
CSChao Su
Chao Su
SKShida Kuang
Shida Kuang
YXYilin Xiong
Yilin Xiong
SGShuguang Gao
Shuguang Gao
Objective. To evaluate the efficacy and safety of oral colchicine in the treatment for knee OA. Design. Meta‐analysis. Data Sources. Embase, PubMed (MEDLINE), the Cochrane Library, and Web of Science from inception to December 12, 2021. Study Selection. RCTs comparing colchicine with placebo for knee OA were included. No language or date restrictions were applied. Two authors abstracted data and determined quality. Outcomes of interest included VAS‐pain, WOMAC total index, and patient‐reported adverse events. Results. A total of five RCTs including 400 adult patients with OA met the inclusion criteria. The mean age of patients included was 56.05 years (range 21 to 79), and 80.87% were female. There was no difference in VAS‐pain (MD ‐1.49; 95% CI ‐3.15, 0.17; p = 0.08) when compared colchicine group with placebo group. And there was no statistically difference in WOMAC total index (std. MD ‐0.13; 95% CI ‐0.64, 0.38; p = 0.61) and patient report adverse events (RR 1.23; 95% CI 0.72, 2.11; p = 0.46). Conclusion. Colchicine is not currently recommended as a treatment for knee OA but might have insignificant effect. The conclusion is limited due to the variation in assessment indicator among available data. Further RCTs with larger sample size and longer follow‐up are needed to confirm the findings.

30 September 2020 in Orthopaedic Surgery
Verified
Journal Article
Open access
PDF file
YXYilin Xiong
Yilin Xiong
CSChao Su
Chao Su
SKShi‐Da Kuang
Shi‐Da Kuang
XZXIN ZHAO
XIN ZHAO
YLYu‐Sheng Li
Yu‐Sheng Li
SGShuguang Gao
Shuguang Gao
Anatomic tunnel formation and remnant preservation are the recent trends in posterior cruciate ligament (PCL) reconstruction. However, it is difficult to observe the anatomical PCL footprint and perform the operation in the process of remnant‐preserving PCL reconstruction. This study describes a single‐bundle, transtibial PCL reconstruction technique with anatomic graft passage over the remnant PCL fibers. A femoral tunnel of PCL is created at 2 mm medial to the roof of the intercondylar notch and 3 mm proximal to the margin of the articular cartilage. The tibial insertion of PCL is observed using a figure‐of‐four position through a posterior trans‐septal portal. A tibial bone tunnel is made below the distal center portion of the tibial insertion of residual PCL fibers. The graft is passed over the PCL through the tibial bone tunnel, the space between the anterior cruciate ligament (ACL) and the residual PCL fibers, to the femoral socket and is fixed by the EndoButton and screw. This technique is able to ensure a reasonable intra‐articular length and optimal isometry. It has been applied in patients with PCL rupture and posterior instability of the knee joint, and no intraoperative or postoperative complications occurred. Our technology provides a valuable new treatment option for PCL rupture. Future comparative studies are needed to further clarify its beneficial effect.