Dibyashree Poudyal

Dibyashree Poudyal

Auto-generated profile, based on publicly available information

Dibyashree Poudyal

Department of Civil, Nepal Engineering College

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2024 in Journal of Geophysics and Engineering
Verified
Journal Article
Open access
PDF file
DPDibyashree Poudyal
Dibyashree Poudyal
NNNorhaiza Nordin
Norhaiza Nordin
SRSiti Nur Aliaa Roslan
Siti Nur Aliaa Roslan
BDBhim Kumar Dahal
Bhim Kumar Dahal
Kathmandu Valley situated in Nepal has experienced several earthquakes in the past. The expanding population of Kathmandu Valley is driving a significant acceleration in building construction reaching record levels and posing risks to both human lives and the economy, despite this surge in development. This study aimed to spatially map the dominant frequency, amplification factor, and vulnerability index map of Kathmandu Valley, Nepal using ArcGIS. This paper presents the nonlinear response analysis of 225 boreholes using the Gorkha earthquake as input motion and DEEPSOIL software for determining the amplification ratio and dominant frequency. The results revealed a range of values for dominant frequency from |$0.08$| to |$7.65$|Hz and soil amplification ratio from |$0.13$| to |$8.14$|⁠. Furthermore, the seismic vulnerability index was derived from the dominant frequency and soil amplification ratio ranging from |$0.22$|to |$21.84$|⁠. The resulting maps acquired through this study enable the decision-makers and stakeholders, to prioritize resources and implement targeted measures for enhancing seismic resilience in the region.

29 March 2025 in Contributions to Geophysics and Geodesy
Verified
Journal Article
Closed access
PDF file
DPDibyashree Poudyal
Dibyashree Poudyal
NNNorhaiza Nordin
Norhaiza Nordin
SRSiti Nur Aliaa Roslan
Siti Nur Aliaa Roslan
Kathmandu Valley, the capital of Nepal, is located in the seismically active Himalayan belt and has a history of devastating earthquakes causing substantial loss of life and property damage. This study employs Probabilistic Seismic Hazard Analysis (PSHA) using the Foulser-Piggott Attenuation (FPA) model and Travasarou et al. (2003) with R-CRISIS software to calculate Arias intensity in Kathmandu Valley. Historical and recent seismic data within a 500-km radius were analysed, and the earthquake catalogue was declustered and standardized using ZMAP software, a tool developed for the statistical analysis and visualization of earthquake catalogues. Additionally, a Digital Elevation Model (DEM) based topographic analysis was conducted to assess the impact of local topography on seismic site response providing insights into, slope, soil amplification factors, and shear wave velocity across the region. The results reveal Arias intensity values ranging from 0.225 to 0.241 m/s at 2% and 10% probability of exceedance corresponding to 475 and 2475 years, mapped using ArcGIS. The analysis revealed that southwestern Kathmandu and Lalitpur exhibit higher Arias intensity values, while intensity decreases gradually from southwest to northeast. The DEM analysis further revealed that areas with low slopes, particularly in central Kathmandu, have higher soil amplification factors, potentially amplifying seismic waves. The shear wave velocity distribution highlights lower values in sedimentary deposits, indicating increased seismic vulnerability. These findings emphasize the need for effective urban planning and disaster preparedness strategies to mitigate earthquake impacts in Kathmandu Valley.

4 December 2025 in Geomechanics and Geoengineering
Verified
Journal Article
Closed access
DLDibyashree Poudyal Lohani
Dibyashree Poudyal Lohani
CBCrystal Banjade
Crystal Banjade
ADAashutosh Dahal
Aashutosh Dahal
ASAvinash Kumar Shah
Avinash Kumar Shah
MYMadav Kumar Yadav
Madav Kumar Yadav

10 May 2023 in Research Square
Verified
Preprint
Open access
PDF file
DPDibyashree Poudyal
Dibyashree Poudyal
NNNorhaiza Nordin
Norhaiza Nordin
KGKunal Gupta
Kunal Gupta
NSNeelima Satyam
Neelima Satyam
SRSiti Nur Aliaa Roslan
Siti Nur Aliaa Roslan
BDBhim Kumar Dahal
Bhim Kumar Dahal
The Kathmandu Valley, situated in a region with high seismic activity, has experienced numerous earthquakes in the past. The Gorkha earthquake in Nepal has increased the probability of significant earthquakes happening in the future along this orogenic belt, including the Valley. In this study, an effort has been made to conduct a detailed probabilistic seismic hazard analysis of the Kathmandu Valley by considering earthquakes between 1900 and 2023. A complete catalog of the quake was compiled, encompassing entire seismic events within a 300 Kilometers range. The earthquake catalog was employed to homogenize the magnitude into moment magnitude (Mw) scale using global relationships, and Gardner and Knopoff's algorithm for declustering was used to filter dependent events. Catalog completeness was evaluated using Stepp's technique, and recurrence parameters were calculated using Gutenberg-Richter's law, which is necessary for probabilistic seismic hazard analysis. This study uses a seismic hazard analysis tool R-CRISIS. Global attenuation models within a logic tree were employed to evaluate interface events in Nepal. The findings were presented through maps depicting an Arias intensity, peak ground acceleration, and peak ground velocity for 50-year periods with 2% and 10% risk of exceedance. This study of ground motion will assist in future seismological analysis before developing future infrastructures.

30 October 2026 in Journal of Structural Fire Engineering
Verified
Journal Article
Closed access
DLDibyashree Poudyal Lohani
Dibyashree Poudyal Lohani
EJEshwar Raj Joshi
Eshwar Raj Joshi
NDNabaraj Dhungel
Nabaraj Dhungel
SKSarmila Khadka
Sarmila Khadka
MMMilan Malla
Milan Malla
SGSantosh Ghimire
Santosh Ghimire
Purpose: This study aims to assess the post-fire structural integrity of an eight-story reinforced concrete government building in Kathmandu, Nepal, following a 24-h fire event during civil unrest. The research evaluates residual material strength through nondestructive and semi-destructive testing (NDT and SDT), identifies seismic vulnerabilities using Extended Three-Dimensional Analysis of Building Systems (ETABS) analysis and develops a cost-effective retrofit strategy. The purpose is to demonstrate that fire-damaged RCC buildings can be structurally restored without demolition, offering a practical alternative to reconstruction in developing countries where design documentation is often incomplete and resources are constrained. Design/methodology/approach: A multi-tiered investigation was conducted comprising visual damage mapping, nondestructive testing (rebound hammer and ultrasonic pulse velocity), semi-destructive testing (core extraction, carbonation measurement and rebar elongation tests) and three-dimensional ETABS analysis. Three progressive models were developed: Model I (damaged structure), Model II (steel jacketing of columns) and Model III (steel jacketing + X-bracing). Seismic performance was evaluated per IS 1893:2002 criteria, including story drift, torsional irregularity and P-M-M interaction ratios. The retrofit strategy was validated through comparative analysis of pre- and post-retrofit performance. Findings: Residual concrete strengths in fire-affected zones ranged from 16.83 MPa to 26.47 MPa, with carbonation depths reaching 25 mm. Structural analysis revealed story drift exceeding the 0.004 limit (maximum 0.005424) and torsional irregularity ratios reaching 1.28 against the 1.2 limit. Column steel jacketing alone restored local member capacity but failed to resolve global seismic deficiencies. The addition of steel X-bracing at perimeter frames successfully redistributed lateral stiffness, achieving full code compliance with drift reduced to 0.002227 and torsional ratios below 1.14. Retrofit cost was estimated at 40–50% of replacement cost. Research limitations/implications: Original design drawings were unavailable; existing reinforcement was characterized using rebar scanning which cannot reliably determine bar diameter or grade. Fire temperature history was not recorded; peak temperatures were inferred from material degradation patterns. Foundation integrity was assessed visually without excavation or load testing. The lowest core strength (16.83 MPa) was conservatively applied to all fire-affected flexural elements, which may overestimate damage in some areas. Full-scale destructive testing was not conducted. These limitations are consistent with typical post-fire assessments where documentation is unavailable and instrumentation was not present during the fire. Practical implications: The retrofit strategy offers a cost-effective alternative to demolition and reconstruction, with estimated costs of 40–50% of replacement cost and a construction timeline of 8–10 months compared to 24–30 months for new construction. The systematic assessment methodology – combining visual inspection, NDT/SDT and Extended Three-Dimensional Analysis of Building Systems analysis – provides a practical template for evaluating fire-damaged buildings in developing countries where design documentation is often incomplete. The finding that steel jacketing alone is insufficient to resolve torsional irregularity highlights the need for system-level seismic interventions in fire-damaged structures. Social implications: Preserving the Kathmandu District Court Building avoids relocation of court functions, loss of evidence and records, and significant public inconvenience. The building serves as a vital judicial infrastructure for Kathmandu District, housing courtrooms, judge chambers, administrative offices and record storage. Its restoration ensures continued access to justice for the community without disruption. The study demonstrates that infrastructure damaged during civil unrest can be systematically restored rather than demolished, promoting resilience and continuity of essential government services. The approach is applicable to other public buildings damaged by fire in developing countries. Originality/value: This study presents the first documented case in Nepal of post-fire seismic retrofit of an RC building integrating field-based damage mapping, NDT/SDT material testing and system-level seismic evaluation. It uniquely demonstrates that asymmetric fire damage to shear walls creates torsional irregularity (max/avg drift 1.28 > 1.2 limit) – a vulnerability that persists after column jacketing and requires system-level intervention. The poor NDT correlation (R2 = 0.0004) provides field evidence that rebound hammer alone is unreliable for fire-damaged concrete assessment. The validated retrofit strategy offers a practical, cost-effective model for similar structures in developing countries.