Wouter M. van Everdingen

Wouter M. van Everdingen

Auto-generated profile, based on publicly available information

Wouter M. van Everdingen

Department of Cardiology, University Medical Centre Utrecht, Utrecht, The Netherlands

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2020 in Radiology
Verified
Journal Article
Closed access
MPMathias Prokop
Mathias Prokop
WEWouter van Everdingen
Wouter van Everdingen
TVTjalco van Rees Vellinga
Tjalco van Rees Vellinga
JUJet Quarles van Ufford
Jet Quarles van Ufford
Lauran StögerLauran Stöger
Lauran Stöger
FSfor The “COVID-19 Standardized Reporting” Working Group of the Dutch Radiological Society
for The “COVID-19 Standardized Reporting” Working Group of the Dutch Radiological Society
Purpose To introduce the COVID-19 Reporting and Data System (CO-RADS) for standardized assessment of pulmonary involvement of COVID-19 on non-enhanced chest CT and report its initial interobserver ...

17 October 2017 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
WEWouter M. van Everdingen
Wouter M. van Everdingen
AZAlwin Zweerink
Alwin Zweerink
RNRobin Nijveldt
Robin Nijveldt
OSOdette A. E. Salden
Odette A. E. Salden
MMMathias Meine
Mathias Meine
MCMaarten J. M. Cramer
Maarten J. M. Cramer
Parameters using myocardial strain analysis may predict response to cardiac resynchronization therapy (CRT). As the agreement between currently available strain imaging modalities is unknown, three different modalities were compared. Twenty-seven CRT-candidates, prospectively included in the MARC study, underwent cardiac magnetic resonance (CMR) imaging and echocardiographic examination. Left ventricular (LV) circumferential strain was analysed with CMR tagging (CMR-TAG), CMR feature tracking (CMR-FT), and speckle tracking echocardiography (STE). Basic strain values and parameters of dyssynchrony and discoordination obtained with CMR-FT and STE were compared to CMR-TAG. Agreement of CMR-FT and CMR-TAG was overall fair, while agreement between STE and CMR-TAG was often poor. For both comparisons, agreement on discoordination parameters was highest, followed by dyssynchrony and basic strain parameters. For discoordination parameters, agreement on systolic stretch index was highest, with fair intra-class correlation coefficients (ICC) (CMR-FT: 0.58, STE: 0.55). ICC of septal systolic rebound stretch (SRSsept) was poor (CMR-FT: 0.41, STE: 0.30). Internal stretch factor of septal and lateral wall (ISFsep–lat) showed fair ICC values (CMR-FT: 0.53, STE: 0.46), while the ICC of the total LV (ISFLV) was fair for CMR-FT (0.55) and poor for STE (ICC: 0.32). The CURE index had a fair ICC for both comparisons (CMR-FT: 0.49, STE 0.41). Although comparison of STE to CMR-TAG was limited by methodological differences, agreement between CMR-FT and CMR-TAG was overall higher compared to STE and CMR-TAG. CMR-FT is a potential clinical alternative for CMR-TAG and STE, especially in the detection of discoordination in CRT-candidates.

26 July 2018 in ESC Heart Failure
Verified
Journal Article
Open access
PDF file
AZAlwin Zweerink
Alwin Zweerink
WEWouter M. van Everdingen
Wouter M. van Everdingen
RNRobin Nijveldt
Robin Nijveldt
OSOdette A.E. Salden
Odette A.E. Salden
MMMathias Meine
Mathias Meine
CACornelis P. Allaart
Cornelis P. Allaart
Aims Various strain parameters and multiple imaging techniques are presently available including cardiovascular magnetic resonance (CMR) tagging (CMR‐TAG), CMR feature tracking (CMR‐FT), and speckle tracking echocardiography (STE). This study aims to compare predictive performance of different strain parameters and evaluate results per imaging technique to predict cardiac resynchronization therapy (CRT) response. Methods and results Twenty‐seven patients were prospectively enrolled and underwent CMR and echocardiographic examination before CRT implantation. Strain analysis was performed in circumferential (CMR‐TAG, CMR‐FT, and STE‐circ) and longitudinal (STE‐long) orientations. Regional strain values, parameters of dyssynchrony, and discoordination were calculated. After 12 months, CRT response was measured by the echocardiographic change in left ventricular (LV) end‐systolic volume (LVESV). Twenty‐six patients completed follow‐up; mean LVESV change was −29 ± 27% with 17 (65%) patients showing ≥15% LVESV reduction. Measures of dyssynchrony (SD‐TTPLV) and discoordination (ISFLV) were strongly related to CRT response when using CMR‐TAG (R2 0.61 and R2 0.57, respectively), but showed poor correlations for CMR‐FT and STE (all R2 ≤ 0.32). In contrast, the end‐systolic septal strain (ESSsep) parameter showed a consistent high correlation with LVESV change for all techniques (CMR‐TAG R2 0.60; CMR‐FT R2 0.50; STE‐circ R2 0.43; and STE‐long R2 0.43). After adjustment for QRS duration and QRS morphology, ESSsep remained an independent predictor of response per technique. Conclusions End‐systolic septal strain was the only parameter with a consistent good relation to reverse remodelling after CRT, irrespective of assessment technique. In clinical practice, this measure can be obtained by any available strain imaging technique and provides predictive value on top of current guideline criteria.

1 October 2017 in Journal of the American Society of Echocardiography
Verified
Journal Article
Closed access
WEWouter M. van Everdingen
Wouter M. van Everdingen
JWJohn Walmsley
John Walmsley
MCMaarten J. Cramer
Maarten J. Cramer
IHIris van Hagen
Iris van Hagen
BBBart W.L. De Boeck
Bart W.L. De Boeck
GLGeert E. Leenders
Geert E. Leenders

6 March 2015 in Journal of Cardiovascular Translational Research
Verified
Journal Article
Open access
PDF file
CDCaroline J. M. van Deursen
Caroline J. M. van Deursen
LWLiliane Wecke
Liliane Wecke
WEWouter M. van Everdingen
Wouter M. van Everdingen
MSMarcus Ståhlberg
Marcus Ståhlberg
MJMichel H. G. Janssen
Michel H. G. Janssen
FPF.W. W. Prinzen
F.W. W. Prinzen
Current optimization of atrioventricular (AV) and interventricular (VV) intervals in cardiac resynchronization therapy (CRT) is time consuming and subject to noise. We aimed to prove the principle that the best hemodynamic effect of CRT is achieved by cancelation of opposing electrical forces, detectable from the QRS morphology in the 3D vectorcardiogram (VCG). Different degrees of left (LV) and right ventricular (RV) pre-excitation were induced, using variation in AV intervals during LV pacing in 20 patients with left bundle branch block (LBBB) and variation in VV intervals during biventricular pacing in 18 patients with complete AV block or atrial fibrillation. The smallest QRS vector area identified stimulation intervals with minimal systolic stretch (median difference [IQR] 20 ms [−20, 20 ms] and maximal hemodynamic response (10 ms [−20, 40 ms]). Reliability of VCG measurements was superior to hemodynamic measurements. This study proves the principle that VCG analysis may allow easy and reliable optimization of stimulation intervals in CRT patients.

1 March 2018 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
WEWouter M. van Everdingen
Wouter M. van Everdingen
AZAlwin Zweerink
Alwin Zweerink
MCMaarten J. Cramer
Maarten J. Cramer
PDPieter A. Doevendans
Pieter A. Doevendans
UNUyen Chau Nguyen
Uyen Chau Nguyen
MMMathias Meine
Mathias Meine
Background: Previous studies indicated the importance of the intrinsic left ventricular (LV) electric delay (QLV) for optimal benefit to cardiac resynchronization therapy. We investigated the use of QLV for achieving optimal acute hemodynamic response to cardiac resynchronization therapy with a quadripolar LV lead. Methods and Results: Forty-eight heart failure patients with a left bundle branch block were prospectively enrolled (31 men; age, 66±10 years; LV ejection fraction, 28±8%; QRS duration, 176±14 ms). Immediately after cardiac resynchronization therapy implantation, invasive LV pressure–volume loops were recorded during biventricular pacing with each separate electrode at 4 atrioventricular delays. Acute cardiac resynchronization therapy response, measured as change in stroke work (Δ%SW) compared with intrinsic conduction, was related to intrinsic interval between Q on the ECG and LV sensing delay (QLV), normalized for QRS duration (QLV/QRSd), and electrode position. QLV/QRSd was 84±9% and variation between the 4 electrodes 9±5%. Δ%SW was 89±64% and varied by 39±36% between the electrodes. In univariate analysis, an anterolateral or lateral electrode position and a high QLV/QRSd had a significant association with a large Δ%SW (all P <0.01). In a combined model, only QLV/QRSd remained significantly associated with Δ%SW ( P <0.05). However, a direct relation between QLV/QRSd and Δ%SW was only seen in 24 patients, whereas 24 patients showed an inverse relation. Conclusions: The large variation in acute hemodynamic response indicates that the choice of the stimulated electrode on a quadripolar lead is important. Although QLV/QRSd was associated with acute hemodynamic response at group level, it cannot be used to select the optimal electrode in the individual patient.