31 March 2020 in IEEE Transactions on Power Electronics
The low-voltage ride through condition (LVRT) attracts wider attention with the increased power of central grid-connected photovoltaic (PV) systems. The conventional double-loop-based control strategy designed for the nominal voltage is slow and potentially unstable under the LVRT operation. In this article, a novel sliding-mode control-based feedback linearization is proposed to improve response speed of the PV system under LVRT condition. To increase the robustness of the control to parameter variations, sliding-mode control is combined with the feedback linearization in this article. Further, the complete linearization of the PV system can be achieved over the whole operating range. Moreover, the dc-link voltage operating point of the PV panel can be dynamically adjusted based on the drop depth of the grid voltage, which will reduce the load changes during the LVRT and subsequently ensure the ac current levels to stay within the design limits in any fault situation and enhance the LVRT capability of the central grid-connected PV system. Finally, a 100-kW PV inverter is built to validate the feasibility and effectiveness of the proposed strategy for LVRT.
13 March 2023 in IEEE Transactions on Power Electronics
High step-down dc/dc converters with high efficiency and high power density are widely used in data centers, dc distribution grids and hybrid electric vehicles. In this article, a new resonant switched capacitor converter is proposed, which can not only realize high step-down conversion, but also operate in multiple-modes to achieve various voltage ratios. The duty cycle can be allocated to one-half and one-third, enabling the converter to operate in double-mode and triple-mode accordingly. In addition, the state of the basic resonant cell can be switched between series and parallel, which enriches the operating modes, and thus allowing the converter to achieve different voltage ratios. Furthermore, the principle and strategy of switching between operating modes with different voltage ratios and switching between operating modes with same voltage ratio are presented. With the mode switching strategy, this converter can operate in the optimal mode over the wide voltage range and the full load range, thus achieves high efficiency over the full operating range. Finally, five operating modes are selected to verify the feasibility and the correctness of the theoretical analysis
10 December 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
The loads of dc–dc converter (DDC) are mostly constant power loads (CPLs) in dc microgrid. Due to the negative impedance characteristic, CPLs may lead to the nonpassive factor in DDC. Thus, it may result in DDC, not operating reliably at the desired operating point. In this article, a nonlinear controller based on passivity-based stability theory is proposed for the DDC with CPL, which will improve the stability of the converter. Through damping and interconnection injecting, the alternating component passivity-based controller (PBC) is designed to realize the unified control of output voltage and inductor current. It could realize the passivation of alternating component. Furthermore, this controller can solve the problem of traditional PBCs to control inductor current or output voltage only. Moreover, a power observer is adopted, which could fast estimate the variation of the CPL and improve the adaptability of DDC when CPL changes. The proposed controller not only ensures the stability of DDC under large variation of CPL, but also features fast dynamic response with accurate tracking over wide operating range. Finally, the feasibility and effectiveness of the proposed controller are verified by simulation and experimental results.
20 April 2020 in IEEE Access
In this paper, a practical passivity-based control (PBC) with active disturbance rejection control (ADRC) is proposed to improve performance of the Vienna rectifier under unbalanced grid conditions. In general, the traditional double-loop control based on positive and negative sequence transformation is used in Vienna rectifier under unbalanced grid conditions. However, it could not fundamentally solve the additional time delay caused by the second harmonic filter and loss of performance caused by a linear weighted sum of proportional integral (PI) con-troller. What’s more, the complexity of the controller is high for the positive and negative sequence currents need to be controlled separately. The PBC is a nonlinear controller based on energy dissipation and it has strong robustness to interference. Further, the line voltage based PBC in inner current loop can deal with the voltage unbalance effectively and easily without negative sequence transformation. To improve the disturbance rejection ability, the ADRC is ap-plied in outer voltage loop, which could overcome PI’s drawbacks of step overshoot and slow response. Under un-balanced grid conditions, the proposed control strategy has good performance, easy implementation and less con-suming time with PBC control in inner current loop, and it has strong robustness and fast track performance with ADRC control in outer voltage loop. The detailed mathematical model, control principle and controller design of the Vienna rectifier are thoroughly analyzed. In addition, simulation results based on SIMULINK are also given in the paper. Finally, a downsize 5kW Vienna rectifier prototype is built to validate the correctness and effectiveness of the proposed strategy.
2 December 2019 in IEEE Access