Claudio Acuña

Claudio Acuña

Auto-generated profile, based on publicly available information

Claudio Acuña

Department of Chemical and Environmental Engineering Universidad Técnica Federico Santa María 2390123 Valparaíso Chile

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2022 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
CLClaudio Leiva
Claudio Leiva
CAClaudio Acuña
Claudio Acuña
LBLuis Bergh
Luis Bergh
SLSaija Luukkanen
Saija Luukkanen
CSCristóbal da Silva
Cristóbal da Silva
In flotation process, the efficiency and selectivity depend on mineralogy, particle size distribution and liberation, reagents added, mixing, and particle coverage. However, the kinetics of particle recovery is highly dependent on cell hydrodynamic and circuit configuration and operational strategy. Controlling froth depth and gas flow rate, measured as superficial gas velocity, is a straightforward alternative related to kinetics in the froth and collection zones. However, these parameters are not measured accurately. Froth depth measurement is based on a floating device coupled with a sonic sensor; this configuration presents hysteresis and deviation due to variation in the gas holdup and pulp density. In self-aspirated machines, there is no technology to measure gas velocity. To address this problem, the intelligent online gas dispersion sensor based on two concentric HDPE cylindres is proposed. The intelligent online gas dispersion sensor is based on two concentric HDPE cylinders. The methodology improves the accuracy of gas velocity calculation with a new algorithm. Froth depth measurement is based on two pressure transducers, reducing the uncertainty of the floating sonic sensor to 1cm. Pulp bulk density is directly measured, and gas holdup can be estimated. Experimental results and industrial device validation indicate that the new intelligent system can measure superficial gas velocity (Jg) online and self-calibrate, with a 2 error, the froth depth error being 1cm. Therefore, a multiparameter sensor for measuring gas dispersion in industrial flotation cells was experimentally designed and validated in an industrial environment (TRL 8). In this context, the proposed online gas dispersion sensor emerges as a robust technology to improve the operation of the flotation process.

28 October 2025 in Minerals Engineering
Verified
Journal Article
Open access
CVCarmel Vasconcelos
Carmel Vasconcelos
MGMaria Sinche Gonzalez
Maria Sinche Gonzalez
CAClaudio Acuña-Pérez
Claudio Acuña-Pérez
ASAnders Sand
Anders Sand
DBDominique Brising
Dominique Brising
AGAnna Gulkova
Anna Gulkova

19 March 2024 in Physicochemical Problems of Mineral Processing
Verified
Journal Article
Open access
CAClaudio Acuña
Claudio Acuña
CACamila Aedo
Camila Aedo
CLClaudio Leiva
Claudio Leiva
Victor FloresVictor Flores
Victor Flores
Given the significant consumption and future demand for water resources, this paper intends to find the conditions for using a flotation process with different water quality. One of the alternatives is using water under secondary treatment with industrial water mixtures to partly recycle domestic wastewater and maximize metallurgical benefits. Results show that using wastewater (only with secondary treatment) in flotation is detrimental to copper recovery. However, molybdenum recovery is significantly improved. For mixtures with 50 [%] wastewater, 50 [ppm] frother, 20 [ppm] collector, and pH 10, copper recovery decrease amounts to 0.4 [%], while molybdenum shows a 2.4 [%] recovery increase. In addition, copper concentrate grade decreases by 1.4 [%], while molybdenum grade remains. Therefore, using wastewater is viable, particularly in the case of molybdenum. So, this study proposes using of water mixtures in the copper depression stage to improve molybdenum recovery.

1 January 2025
Verified
Conference Paper
Open access
PDF file
DPDiego Alonso Poblete
Diego Alonso Poblete
CLClaudio Leiva
Claudio Leiva
MGMaria Sinche Gonzalez
Maria Sinche Gonzalez
CAClaudio Acuña
Claudio Acuña
A new technology for solvent extraction has been developed. This innovation, Hollow Drop, merges flotation with solvent extraction by using air bubbles coated with an insoluble extractant material. While the concept of coated bubbles is not new, our work focuses on advancing this idea by generating a swarm of coated bubbles to scale up the process. Experimental tests were conducted using dissolved copper solutions, SX extractants, Iodine solutions, and Kerosene, achieving copper recoveries of 70% with aqueous-to-organic (A/O) ratios of 17. These results demonstrate that the coated bubble process can operate continuously and holds promise for industrial-scale implementation.

11 October 2026 in Physicochemical Problems of Mineral Processing
Verified
Journal Article
Open access
PDF file
KRKobra Rezaei
Kobra Rezaei
CAClaudio Acuña
Claudio Acuña
The beneficial effect of sodium chloride on the acidic leaching of sulfide minerals is widely reported and is mostly interpreted through surface-related mechanisms. However, its influence on the oxidation-reduction potential of acidic media, a key parameter governing solution stability and oxidation thermodynamics, remains insufficiently quantified. This work quantifies the effect of NaCl concentration on ORP in NaCl–HCl and NaCl–H₂SO₄ systems. ORP was monitored together with pH, conductivity, temperature and solution composition over acidity ranges up to 2 M and salinities up to 14 wt.% NaCl. NaCl alone produced only minor changes in ORP, whereas its addition to acidic solutions increased the measured potential with a strong dependency on the acid matrix. In NaCl–H₂SO₄ systems, ORP stabilized within a moderate potential range of approximately 580–640 mV (Ag/AgCl). NaCl–HCl systems exhibited two distinct regimes: a moderate regime comparable to that observed in sulfate media and a high redox potential close to 900 mV (Ag/AgCl) under high chloride concentration and strongly acidic conditions. Comparison with 1.6 wt.% FeCl₃ (approximately 0.1 M), used as a conventional oxidant benchmark, showed comparable ORP levels, highlighting the strong influence of NaCl on the measured redox environment under specific acidic conditions. Overall, the measured ORP reflected acid-matrix-dependent mixed-potential behaviour. NaCl modified the measured ORP under acidic conditions, whether present as background salinity or as an additive. However, solution acidity or chloride concentration alone could not produce the same redox potential response. The findings provide a quantitative basis for interpreting ORP behaviour in chloride-containing acidic systems and for evaluating electrochemical conditions relevant to hydrometallurgical process development.

3 January 2024 in Physicochemical Problems of Mineral Processing
Verified
Journal Article
Open access
CLClaudio Leiva
Claudio Leiva
CAClaudio Acuña
Claudio Acuña
SLSaija Luukkanen
Saija Luukkanen
CCConstanza Cruz
Constanza Cruz
This communication presents a methodology, based on a modified drift flux model, to determine bubble size distribution in column flotation. The modified drift flux model incorporates a surfactant-type parameter. This parameter considers the impact of surfactant on bubble hydrodynamics. The methodology aims to improve the accuracy of bubble size distribution prediction, which presents deviation depending on surfactant type (i.e. polyglycolic based or alcoholic base). Many authors have proposed different mathematical improvements to reduce de experimental data deviations in the presence of different surfactants. However, from 1988 to 2022, the determination coefficient, or the quality of the adjustments, from the proposed mathematical models is, at the most, 92% (relative error). The proposed methodology improves the quality of the adjustments to 98.6, adding a single parameter for groups of surfactants. This methodology incorporates a single parameter in the terminal velocity calculation that can compensate for the impact of surfactant type in bubble hydrodynamic (bubble skin friction or drag coefficient, bubble wake, bubble shape, bubble rigidity). This parameter is a function of the gas holdup calculated from gas velocity measured and the bubble size distribution calculated (deviated) from gas holdup and gas velocity measured. The methodology is validated with reported experimental results and proposed modifications from various authors. The confidence interval (2 σ) is reduced from 0.11mm to 0.05mm in the case of (Yianatos, Banisi, Ostadrahimi). In the case of the recently reported experimental results from Maldonado and Gomez, the confidence interval is reduced from 0.31 mm to 0.09 mm. These results improve bubble size estimation based on drift flux in column flotation, contributing to a better understanding of surfactant impact on bubble swarm hydrodynamics.