This paper proposes an updated two-step approach to improve the operation of a distribution network (DN) through the optimal siting and sizing of one, two, or three systems, each consisting of a photovoltaic (PV) generator and a battery energy storage (BES) unit – the so-called “PV-BES system”. The first step of the approach determines the optimal sites and optimal powers of the PV-BES systems, taking into account the DN load profile and the required improvement in DN operation. Parameters used to describe the quality of the DN operation include the average daily power losses and the voltage profile quality index of the DN. The optimal locations and optimal powers of the PV-BES systems are determined using metaheuristics of the particle swarm optimisation (PSO) and wild horse optimisation (WHO) methods considering various daily load profiles. Based on the optimal powers of the first step and the known daily variation of solar irradiation, the second step provides the individual maximum powers of the PV generators and BES units, as well as the storage capacities of the BES units required for the sizing of the PV-BES systems. The iterative method used for the sizing of the PV-BES systems in the second step of the proposed approach can be regarded as a novelty. Finally, all results were obtained using the IEEE 33-bus test radial DN topology, considering different numbers of PV-BES systems connected to the DN, different efficiencies of the BES units, and different priorities in the criterion function.
FPFakultet tehničkih nauka u Kosovskoj Mitrovici Univerzitet u Prištini
Fakultet tehničkih nauka u Kosovskoj Mitrovici Univerzitet u Prištini
This paper considers the influence of the tilt angle of photovoltaic (PV) panels on the total amount of insolation on the surface of these panels on a monthly and annual basis, with and without consideration of shading effect. Based on the obtained results, optimal tilt angles of the PV panels in order to achieve maximum insolation, are determined, as well as the optimal tilt angles for achieving maximum generated electrical energy, taking into account the temperature of the panel. Special attention in the paper is paid to the shading effect created by the panel rows within the PV system and its influence on the reduction of direct component of irradiation and optimal tilt angles for different distances between PV panel rows. In the paper two different models for solar insolation calculation were considered and described in detail, clear day model and real cloud condition model. In order to obtain the average daily solar irradiation on the inclined surface, in addition to appropriate extraterrestrial irradiations, available measurements of the irradiation on the horizontal surface during one year period were used.
22 March 2026 in ICCK Transactions on Electric Power Networks and Systems
This paper proposes the two-step approach for improving the voltage profile of the distribution network (DN) using the optimal integration of photovoltaic-battery energy storage (PV-BES) system. In the first step of the approach the optimal location of the PV-BES system in the DN and its optimal powers are determined, considering the topology and the load of the DN. This is done to improve the voltage profile of the DN using the meta-heuristic wild horse optimization method (WHO) and genetic algorithm (GA). The second step of the approach determines the optimal sizing of the PV-BES system, by taking into account the optimal powers obtained in the first step, the solar irradiance diagram and the average temperature for each month of the year for the area in which the DN is located. The optimal sizing includes optimal maximum power of the PV system and the optimal maximum power and energy capacity of the BES unit, determined by the proposed iterative method. The results are generated using the topology of the IEEE 18-bus radial DN for three different load diagrams, on a monthly and annual basis.
This paper proposes an approach for finding the maximum power point (MPP) location of the photovoltaic (PV) array in the case of partial shading based on the shading pattern recognition. Shading pattern recognition is achieved by determining the necessary solar irradiation for each part of the PV array surface to recreate the existing power-voltage (P-V) curve of the PV array. This is done using the metaheuristic particle swarm optimization (PSO) method in which criterion function is based on comparing the measured powers of the PV array (fitting power points) and the powers calculated using the PV array model for the same voltages. Model of the PV array is created from the PV cell model considering the topology and the partial shading of the PV array surface. The effect of partial shading is included by reducing the photocurrent of the PV cells in the shaded area of the PV array. When the shading pattern is known the location (voltage) of the MPP is found using the P-V curve obtained from the PV array model. Results generated for three different shading patterns show great precision of the proposed approach in determining the MPP location if the PV cell is accurately modeled, and enough number of fitting power points are used.
1 January 2025 in Facta universitatis - series: Electronics and Energetics
This paper determines the optimal placement of bypass diodes in photovoltaic (PV) modules to increase their energy production in the case of partial shading while protecting each PV cell from overheating. Within the optimal placement, the optimal number and the optimal locations of bypass diodes are obtained using the metaheuristic optimization method of genetic algorithm (GA). The optimization method finds the optimal solution by maximizing the power of the maximum power point (MPP) on the power-voltage (P-V) characteristics generated from the created model of the PV module under partial shading. This model is created using the five-parameter single-diode PV cell model and allows the implementation of different shading patterns and different locations of bypass diodes in the PV modules. To simulate the effects of static and dynamic shading of the PV module surface, horizontal, vertical, diagonal, and random shading patterns are used. The obtained results show that the optimal placement of bypass diodes in PV modules can significantly increase their energy production, especially for the cases with low solar irradiance of the shaded PV cells. This energy increment is between 30% and 80 % depending on the shading pattern, when the solar irradiance of the shaded PV cells is 70 % reduced compared to the unshaded cells.
This paper considers the improvement of distribution network operation in high load conditions using photovoltaic (PV) and energy storage systems (ESS). Optimal locations and powers of PV systems and ESS, considering the improvement of distribution network operation, are determined by metaheuristic optimization method of genetic algorithm (GA), where losses in distribution network and its voltage profile are used as quality indicators for distribution network operation. Two approaches are used to determine the optimal power of PV system during the day, depending on the ratio of injected power into the network by the PV system and its maximum available power at a given time. Cases with different load distributions in the distribution network are analyzed, as well as the cases with different number of connected PV systems and ESS. Based on the obtained results, in addition to determining the level of distribution network operation improvement, conclusions are given regarding the impact of load diagram on the number, location and size of PV systems and ESS.