Raokaijuan Wang

Raokaijuan Wang

Auto-generated profile, based on publicly available information

Raokaijuan Wang

Department of Orthodontics, Chongqing University Three Gorges Hospital, Chongqing, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2024 in Advanced Healthcare Materials
Verified
Journal Article
Closed access
RWRaokaijuan Wang
Raokaijuan Wang
XZXiangjun Zha
Xiangjun Zha
JCJouchen Chen
Jouchen Chen
RFRuijie Fu
Ruijie Fu
YFYajun Fu
Yajun Fu
LZlixing zhao
lixing zhao

29 October 2025 in The Korean Journal of Orthodontics
Verified
Journal Article
Open access
RWRaokaijuan Wang
Raokaijuan Wang
YDYangjie Deng
Yangjie Deng
FCFangyuan Cheng
Fangyuan Cheng
JZJiayu Zhang
Jiayu Zhang
CFChengmin Fan
Chengmin Fan
FJFulin Jiang
Fulin Jiang
Since categorization of dental crowding is a crucial parameter in orthodontic diagnosis and tooth-extraction decisions, we aimed to develop an automatic system to categorize crowding levels on intraoral photographs without space analysis. The Dental Crowding Categorization Network (DCC-Net), consisting of segmentation, extraction, and categorization modules, was proposed and optimized by extracting regions of interest and crown centroids. A multicenter dataset including 1,351 maxillary and 1,253 mandibular intraoral photographs was divided in an 8:2 ratio for model training and internal testing, and an additional 100 photographs were collected for external testing. The ground truth was obtained through measurements by experienced orthodontists using intraoral scanning data. The accuracy, precision, recall, and F1-score of the categorization module were calculated, and heatmaps were obtained for model interpretation. Furthermore, a clinical evaluation was performed to compare the diagnostic accuracy of junior orthodontists with and without the assistance of DCC-Net. For the maxilla, the categorization accuracy, precision, recall, and F1-score were 0.7232, 0.7447, 0.6793, and 0.6962, respectively, whereas the corresponding values for categorization in the mandible were 0.7352, 0.7506, 0.6723, and 0.7019, respectively. The heatmaps indicated that DCC-Net could identify the dental arches and regions showing malocclusion. In the clinical evaluation, the diagnostic accuracy of junior orthodontists improved with DCC-Net's assistance, increasing by 9.18% for the maxilla and 12.75% for the mandible. DCC-Net achieved accurate categorization of dental crowding on intraoral photographs. Its rapid predictions may offer insights for guiding tooth extraction in orthodontic treatment, providing valuable reference data for inexperienced orthodontists and improving doctor-patient communication.