11 March 2019 in International Journal of Precision Engineering and Manufacturing
14 May 2012 in Optics Express
We have proposed a modified method to improve the measurement uncertainty of the geometrical thickness and refractive index of a silicon wafer. Because measurement resolution based on Fourier domain analysis depends on the spectral bandwidth of a light source directly, a femtosecond pulse laser having the broad spectral bandwidth of about 100 nm was adopted as a new light source. A phase detection algorithm in Fourier domain was also modified to minimize the effect related to environmental disturbance. Since the wide spectral bandwidth may cause a dispersion effect in the optical parts of the proposed interferometer, it was considered carefully through numerical simulations. In conclusion, the measurement uncertainty of geometrical thickness was estimated to be 48 nm for a double-polished silicon wafer having the geometrical thickness of 320.7 μm, which was an improvement of about 20 times that obtained by the previous method.
22 June 2024 in International Journal of Precision Engineering and Manufacturing
1 September 2013 in Optics Communications
14 December 2015 in Optics Express
We propose and realize a modified spectral-domain interferometer to measure the physical thickness profile and group refractive index distribution of a large glass substrate simultaneously. The optical layout was modified based on a Mach-Zehnder type interferometer, which was specially adopted to be insensitive to mechanical vibration. According to the measurement results of repeated experiments at a length of 820 mm along the horizontal axis, the standard deviations of the physical thickness and group refractive index were calculated to be 0.173 μm and 3.4 × 10−4, respectively. To verify the insensitivity to vibration, the physical thickness values were monitored at a stationary point while the glass panel was swung at an amplitude exceeding 20 mm. The uncertainty components were evaluated, and the combined measurement uncertainty became 161 nm (k = 1) for a glass panel with a nominal thickness of 0.7 mm.
17 September 2021 in Optics Express
In this study, an optical method that allows simultaneous thickness measurements of two different layers distributed over a broad thickness range from several tens of nanometers to a few millimeters based on the integration of a spectroscopic reflectometer and a spectral-domain interferometer is proposed. Regarding the optical configuration of the integrated system, various factors, such as the operating spectral band, the measurement beam paths, and the illumination beam type, were considered to match the measurement positions and effectively separate two measurement signals acquired using both measurement techniques. Furthermore, for the thickness measurement algorithm, a model-based analysis method for high-precision substrate thickness measurements in thin-film specimens was designed to minimize the measurement error caused by thin films, and it was confirmed that the error is decreased significantly to less than 8 nm as compared to that when using a Fourier-transform analysis. The ability to undertake simultaneous thickness measurements of both layers using the proposed system was successfully verified on a specimen consisting of silicon dioxide thin film with nominal thicknesses of 100 nm and 150 nm and a 450 µm-thick silicon substrate, resulting in the exact separation between the two layers. From measurement uncertainty evaluation of a thin-film, a substrate in a thin-film specimen, and a single substrate, the uncertainties were estimated to be 0.12 nm for the thin-film, 0.094 µm for the substrate in a thin-film specimen, and 0.076 µm for the substrate. The measurement performance of thicknesses distributed on multi-scale was verified through comparative measurements using standard measurement equipment for several reference samples.