Anh Thai

Anh Thai

Auto-generated profile, based on publicly available information

Anh Thai

Quantitative Medical Imaging Section, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, MD, USA; Department of Electrical Engineering and Computer Science, Catholic University of America, Washington, DC, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2020 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
TNThanh Nguyen
Thanh Nguyen
VBVy Bui
Vy Bui
ATAnh Thai
Anh Thai
VLVan Lam
Van Lam
CRChristopher Raub
Christopher Raub
GNGeorge Nehmetallah
George Nehmetallah
Microscopy techniques, particularly the family of epifluorescence modalities, are workhorses of modern cell and molecular biology that enable microscale spatial insight. Intensity- and/or phase-based microscopy techniques such as brightfield, phase contrast, differential interference contrast, digital holography, Fourier ptychography, and optical diffraction tomography,1 – 7 among other modalities, have the potential to visualize the subcellular structure. However, these methods depend largely on light scattering that is defined by the internal structure-based index of refraction, which lacks biomolecular specificity. Fluorescence-based techniques, on the other hand, excite fluorophores, which act as labels to spatially localize biological molecules and structures within cells. These imaging techniques, especially fluorescence approaches, involve time-consuming preparation steps and costly reagents, introduce the possibility of signal bias due to photobleaching, and in time-lapse vital imaging, allow for possible misinterpretation of cell behavior due to gradual accumulation of sublethal damage from intense ultraviolet and other wavelengths used to excite molecular labels.8 Thus microscopy of cells is challenging due to the inherent trade-offs in sample preservation, image quality, and data acquisition time and the variability between labeling experiments.

9 December 2025 in Imaging Neuroscience
Verified
Journal Article
Open access
MIM. Okan Irfanoglu
M. Okan Irfanoglu
ANAmritha Nayak
Amritha Nayak
PTPaul Taylor
Paul Taylor
ATAnh Thai
Anh Thai
CPCarlo Pierpaoli
Carlo Pierpaoli
Diffusion MRI (dMRI) data suffer from a number of artifacts, including, but not limited to, low SNR, Gibbs ringing, bulk subject motion, within volume motion, eddy-current distortions, susceptibility-induced EPI distortions, and ghost artifacts. Appropriate pre-processing of diffusion-weighted images prior to model fitting is vital for accurate quantitative analysis. Over the years, the nature of dMRI data has evolved (smaller voxel sizes, significantly larger number of volumes and b-values, wider variety of acquisition paradigms, etc.) as have the required processing tools. Additionally, very large multi-site dMRI studies, on potentially uncooperative subjects (young children, geriatric populations, patients with movement disorders, etc.), have increased the necessity for dMRI processing pipelines that are fast, robustly capable of handling a variety of artifacts/distortions, and that have summary reporting capabilities to pinpoint problematic data. TORTOISE (Tolerably Obsessive Registration and Tensor Optimization Indolent Software Ensemble) (www.tortoisedti.org) has been redesigned, made adaptable and significantly enriched to meet these needs.

7 July 2025 in Magnetic Resonance Imaging
Verified
Journal Article
Open access
ATAnh Thai
Anh Thai
LCLin Ching Chang
Lin Ching Chang
CPCarlo Pierpaoli
Carlo Pierpaoli
MIM. Okan Irfanoglu
M. Okan Irfanoglu
To propose and develop an image processing-based methodology for detecting and correcting residual Nyquist ghost artifacts in echo planar imaging (EPI), specifically using non-diffusion-weighted (b=0s/mm2) images acquired with four distinct phase-encoding directions (PEDs) in diffusion MRI. Previous studies have demonstrated that acquiring images with four different PEDs can improve the reproducibility of diffusion derived quantitative maps. This improvement is achieved by averaging across PEDs to reduce the impact of residual EPI Nyquist ghost artifacts. These residual artifacts originate from imperfect ghost correction applied during image reconstruction and often persist into the preprocessing pipeline, potentially biasing downstream analyses. Building on these observations, the proposed method further improves this 4-way encoding approach by leveraging the properties of signal distributions to detect artifactual regions, specifically in non-diffusion weighted (b=0s/mm2). While the corrections are applied only to the b=0 images, its effectiveness is evaluated through downstream diffusion tensor estimation, by assessing the improvements in diffusion-derived metrics such as FA and MD. Additionally, the method can be tailored for specific artifact manifestations by considering their localization due to underlying acquisition parameters. Simulations with known ground-truth images demonstrated high artifact detection accuracy, achieving a Dice score of 0.91 for reconstructions without parallel imaging. In the in-vivo dataset, the method also improved longitudinal reproducibility, reducing variability by 30 % in ghost-affected regions. The proposed correction method effectively detected and corrected residual ghost artifacts without the need of any additional k-space data, specifically in non-diffusion weighted images. This retrospective approach can be directly integrated into existing processing pipelines to further improve the quality of EPI images and enhancing image quality in studies that utilize 4-way PEDs acquisition.

16 December 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
ATAnh Thai
Anh Thai
Lin-Ching ChangLin-Ching Chang
Lin-Ching Chang
CPCarlo Pierpaoli
Carlo Pierpaoli
MIM. Okan Irfanoglu
M. Okan Irfanoglu
Purpose To propose and develop an image processing-based methodology for detecting and correcting echo planar imaging (EPI) artifact that employs data from 4-way phase-encoding acquisitions. Approach Previous studies have demonstrated that acquiring images with four different phase-encoding directions can improve the reproducibility of diffusion derived quantitative maps while retaining the same acquisition time. This improvement is achieved by averaging across phase-encoding directions (PEDs) to reduce the impact of EPI artifacts. Building on this principle, the proposed method further improves this 4-way encoding approach by leveraging the properties of signal distributions to detect artifactual regions. Additionally, the method can be tailored for specific artifact manifestations by considering their localization due to underlying acquisition parameters. The proposed method is applied to and validated using both simulated data and in-vivo diffusion MRI data affected by residual ghost artifacts. Results Simulations with known ground-truth images demonstrated high artifact detection accuracy, achieving a Dice score of 0.91 for reconstructions without parallel imaging. In the in-vivo dataset, the method also improved longitudinal reproducibility, reducing variability by 30% in ghost-affected regions. Conclusion The proposed correction method effectively detected and corrected residual ghost artifacts without the need of any additional k-space data. This retrospective approach can be directly integrated into existing processing pipelines to further improve the quality of EPI images and enhancing image quality in studies that utilize 4-way PEDs acquisition.