Thermochromic windows are smart glazing systems with temperature-dependent optical properties. Optimizing their performance in single- and double-glazed configurations is important for reducing building energy consumption while maintaining occupant thermal and visual comfort. This study develops a multi-objective optimization framework for thermochromic window systems across nine cities with different climates. Design variables include window configuration (single or double glazing), outer-layer glazing type (clear or thermochromic), inner clear pane thickness, thermochromic interlayer thickness, type and thickness of the gas fill between panes, building orientation, and window-to-wall ratio on the south façade. Objective functions are total energy consumption (E), Discomfort Glare Index (DGI), and Predicted Percentage of Dissatisfied (PPD). The NSGA-II algorithm solves the three-objective optimization problem, producing a three-dimensional Pareto front, and a mapping method selects the final solution.With equal weights for all objectives, the optimal configuration for all nine climates is a thermochromic double-glazed window with a clear inner pane and inert gas fill—xenon for seven cities and krypton for Shiraz and Bandar Abbas. Compared with the clear single-glazed window, optimized designs reduce E by up to 23.79%, DGI by up to 20.15%, and PPD by up to 8.20%, depending on climate. A window-to-wall ratio of about 14.85% is optimal for most climates, whereas a much smaller ratio of 3% is preferred in the hot city of Bandar Abbas to limit solar gains. Overall, these findings show that thermochromic double-glazed windows can effectively balance energy efficiency, thermal comfort, and visual comfort across diverse climatic conditions.