Vamsi Krishna Gontu

Vamsi Krishna Gontu

Auto-generated profile, based on publicly available information

Vamsi Krishna Gontu

Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2022 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
Keng Siang LeeKeng Siang Lee
Keng Siang Lee
ISIsabel Siow
Isabel Siow
JZJohn Jy Zhang
John Jy Zhang
NSNicholas L Syn
Nicholas L Syn
CGConor S Gillespie
Conor S Gillespie
LYleonard Litt Yeo yeo
leonard Litt Yeo yeo
Background Mechanical thrombectomy (MT) is an effective treatment for patients with acute ischemic stroke (AIS) from basilar artery occlusion (BAO). Objective To compare the clinical outcomes of MT, with and without bridging intravenous thrombolysis (IVT), in acute BAO through a systematic review and meta-analysis of the current literature. Methods Systematic searches of Medline, EMBASE, and Cochrane Central were undertaken on August 1, 2022. Good functional outcome defined as 90-day modified Rankin Scale score 0–2 was the primary outcome measure. Secondary outcome measures were 90-day mortality, successful post-thrombectomy recanalization (modified Thrombolysis in Cerebral Infarction score ≥2b), symptomatic intracranial hemorrhage (sICH), and subarachnoid hemorrhage (SAH). Results Three studies reporting 1096 patients with BAO AIS were included in the meta-analysis. No significant differences in good functional outcome were detected between the two groups (RR=1.28 (95% CI 0.86 to 1.92); p=0.117). However, specifically patients with large artery atherosclerosis (LAA) benefited from bridging IVT (OR=2.52 (95% CI 1.51 to 4.22); p<0.001) with better functional outcomes. There was a significantly lower 90-day mortality rate for patients who underwent bridging IVT compared with MT alone (RR=0.70 (95% CI 0.62 to 0.80); p=0.008). No significant differences were detected in rates of post-treatment recanalization (RR=1.01 (95% CI 0.35 to 2.91); p=0.954), sICH (RR=0.96 (95% CI 0.66 to 1.42); p=0.724), and SAH (RR=0.93 (95% CI 0.31 to 2.83); p=0.563). Conclusions In patients with AIS due to BAO, bridging IVT was associated with lower mortality rates at 90 days, compared with direct MT. There were no improved functional outcomes or increased sICH or SAH between both arms, However, patients with LAA benefited from bridging IVT, with better functional outcomes.

24 March 2018 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
PBPatrick A Brouwer
Patrick A Brouwer
LYleonard Litt Yeo yeo
leonard Litt Yeo yeo
AHAke Holmberg
Ake Holmberg
TATommy Andersson
Tommy Andersson
JKJens Kolloch
Jens Kolloch
MSMichael Söderman
Michael Söderman
Background We studied patients treated with the EmboTrap revascularization device in a prospective registry which is core laboratory evaluated by physicians from external centers. The goal was to determine how the EmboTrap would perform under the everyday conditions of a high-volume stroke center. Methods We examined all patients with acute stroke treated with the Embotrap device from October 2013 to March 2017 in our center. Imaging parameters and times were adjudicated by core laboratory personnel blinded to clinical information, treating physician, and clinical outcomes. Clinical evaluation was performed by independent neurologists and entered in a national registry. Evaluated endpoints were: successful revascularization (modified Thrombolysis in Cerebral Infarction (mTICI) 2b–3) and good clinical outcomes at 3 months (modified Rankin Scale (mRS) 0–2). Results 201 consecutive patients with a median NIH Stroke Scale (NIHSS) score of 15 (range 2–30) were included. 170 patients (84.6%) achieved mTICI 2b–3 reperfusion. The median number of attempts was 2 (range 1–10) with 52.8% of the population achieving good functional outcomes (mRS 0–2) at 3 months. On univariate analysis, good functional outcome was associated with the number of attempts, puncture-to-reperfusion time, anterior circulation occlusion, and NIHSS score. On multivariate analysis, pre-treatment NIHSS (OR 0.845 per point, 95% CI 0.793 to 0.908, P<0.001) and puncture-to-reperfusion time (OR 0.9952 per min, 95% CI 0.9914 to 0.9975, P=0.023) were associated with good functional outcomes at 3 months. Conclusion The Embotrap device has a high rate of successful reperfusion. Our core laboratory-audited single-center experience suggests the technical feasibility and safety of the Embotrap for first-line use in a real-world setting.

11 January 2022 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
YTYao Neng Teo
Yao Neng Teo
CSChing-Hui Sia
Ching-Hui Sia
Benjamin Yong-Qiang TanBenjamin Yong-Qiang Tan
Benjamin Yong-Qiang Tan
JMJing Mingxue
Jing Mingxue
BCBernard Chan
Bernard Chan
LYleonard Litt Yeo yeo
leonard Litt Yeo yeo
Background: The use of a combination of balloon guide catheter (BGC), aspiration catheter, and stent retriever in acute ischemic stroke thrombectomy has not been shown to be better than a stent retriever and BGC alone, but this may be due to a lack of power in these studies. We therefore performed a meta-analysis on this subject. Methods: A systematic literature search was performed on PubMed, Scopus, Embase/Ovid, and the Cochrane Library from inception to October 20, 2021. Our primary outcomes were the rate of successful final reperfusion (Treatment in Cerebral Ischemia (TICI) 2c–3) and first pass effect (FPE, defined as TICI 2c–3 in a single pass). Secondary outcomes were 3 month functional independence (modified Rankin Scale score of 0–2), mortality, procedural complications, embolic complications, and symptomatic intracranial hemorrhage (SICH). A meta-analysis was performed using RevMan 5,4, and heterogeneity was assessed using the I2 test. Results: Of 1629 studies identified, five articles with 2091 patients were included. For the primary outcomes, FPE (44.9% vs 45.4%, OR 1.04 (95% CI 0.90 to 1.22), I2=57%) or final successful reperfusion (64.5% vs 68.6%, OR 0.98 (95% CI 0.81% to 1.20%), I2=85%) was similar between the combination technique and stent retriever only groups. However, the combination technique had significantly less rescue treatment (18.8% vs 26.9%; OR 0.70 (95% CI 0.54 to 0.91), I2=0%). This did not translate into significant differences in secondary outcomes in functional outcomes, mortality, emboli, complications, or SICH. Conclusion: There was no significant difference in successful reperfusion and FPE between the combined techniques and the stent retriever and BGC alone groups. Neither was there any difference in functional outcomes, complications, or mortality.

3 September 2020 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
BTBenjamin Y Q Tan
Benjamin Y Q Tan
ALAloysius Sheng‑Ting Leow
Aloysius Sheng‑Ting Leow
TLTsong-Hai Lee
Tsong-Hai Lee
VGVamsi Krishna Gontu
Vamsi Krishna Gontu
TATommy Andersson
Tommy Andersson
LYleonard Litt Yeo yeo
leonard Litt Yeo yeo
Background Endovascular thrombectomy (ET) has transformed acute ischemic stroke (AIS) therapy in patients with large vessel occlusion (LVO). Left ventricular systolic dysfunction (LVSD) decreases global cerebral blood flow and predisposes to hypoperfusion. We evaluated the relationship between LVSD, as measured by LV ejection fraction (LVEF), and clinical outcomes in patients with anterior cerebral circulation LVO who underwent ET. Methods This multicenter retrospective cohort study examined anterior circulation LVO AIS patients from six international stroke centers. LVSD was measured by assessment of the echocardiographic LVEF using Simpson’s biplane method of discs according to international guidelines. LVSD was defined as LVEF <50%. The primary outcome was defined as a good functional outcome using a modified Rankin Scale (mRS) of 0–2 at 3 months. Results We included 440 AIS patients with LVO who underwent ET. On multivariate analyses, pre-existing diabetes mellitus (OR 2.05, 95% CI 1.24 to 3.39;p=0.005), unsuccessful reperfusion (Treatment in Cerebral Infarction (TICI) grade 0-2a) status (OR 4.21, 95% CI 2.04 to 8.66; p<0.001) and LVSD (OR 2.08, 95% CI 1.18 to 3.68; p=0.011) were independent predictors of poor functional outcomes at 3 months. On ordinal (shift) analyses, LVSD was associated with an unfavorable shift in the mRS outcomes (OR 2.32, 95% CI 1.52 to 3.53; p<0.001) after adjusting for age and ischemic heart disease. Conclusion Anterior circulation LVO AIS patients with LVSD have poorer outcomes after ET, suggesting the need to consider cardiac factors for ET, the degree of monitoring and prognostication post-procedure.

1 March 2021 in Journal Of Neuroradiology
Verified
Journal Article
Open access
FSFredrik Ståhl
Fredrik Ståhl
VGVamsi Gontu
Vamsi Gontu
HAHåkan Almqvist
Håkan Almqvist
MMMichael V Mazya
Michael V Mazya
ADAnna Falk Delgado
Anna Falk Delgado
Dual energy CT is increasingly available and used in the standard diagnostic setting of ischemic stroke patients. We aimed to evaluate how different dual energy CT virtual monoenergetic energy levels impact identification of early ischemic changes, compared to conventional polyenergetic CT images. This retrospective single-center study included patients presenting with acute ischemic stroke caused by an occlusion of the intracranial internal carotid artery or proximal middle cerebral artery. Data was gathered on consecutive patients admitted to our institution who underwent initial diagnostic stroke imaging with dual layer dual energy CT and a subsequent follow-up CT one to three days after admission. Automated ASPECTS results from conventional polyenergetic and different virtual monoenergetic energy level reconstructions at admission were generated and compared to reference standard ASPECTS. Confidence intervals (CI) for sensitivity, specificity, negative and positive predictive value were calculated. A total of 24 patients were included. Virtual monoenergetic reconstructions of 70 keV had the highest region-based ASPECTS accuracy, 0.90 (sensitivity 0.82 (95% CI 0.72-0.93), specificity 0.92 (0.88-0.97), negative predictive value 0.94 (0.90-0.96)), whereas virtual monoenergetic reconstructions of 40 keV had the lowest, 0.77 (sensitivity 0.34 (0.26-0.42), specificity 0.90 (0.89-0.96), negative predictive value 0.80 (0.77-0.83)). Automated 70 keV ASPECTS had the highest diagnostic accuracy, sensitivity and negative predictive value overall. Our results indicate that virtual monoenergetic energy levels impact the identification of early ischemic changes on CT.

25 July 2024 in Clinical Neuroradiology
Verified
Journal Article
Open access
PDF file
FSFredrik Ståhl
Fredrik Ståhl
HAHåkan Almqvist
Håkan Almqvist
ÅAÅsa Aspelin
Åsa Aspelin
JKJens Kolloch
Jens Kolloch
OGOdett Ghalamkari
Odett Ghalamkari
ADAnna Falk Delgado
Anna Falk Delgado
Purpose: Cone-beam CT in the interventional suite could be an alternative to CT to shorten door-to-thrombectomy time. However, image quality in cone-beam CT is limited by artifacts and poor differentiation between gray and white matter. This study compared non-contrast brain dual-layer cone-beam CT in the interventional suite to reference standard CT in stroke patients. Methods: A prospective single-center study enrolled consecutive participants with ischemic or hemorrhagic stroke. The hemorrhage detection accuracy, per-region ASPECTS accuracy and subjective image quality (Likert scales for gray-white matter differentiation, structure perception and artifacts) were assessed by three neuroradiologists blinded to clinical data on dual-layer cone-beam CT 75 keV monoenergetic images compared to CT. Objective image quality was assessed by region-of-interest metrics. Non-inferiority for hemorrhage detection and ASPECTS accuracy was determined by the exact binomial test with a one-sided lower performance boundary prospectively set to 80% (98.75% CI). Results: 27 participants were included (74 years ± 9; 19 female) in the hyperacute or acute stroke phase. One reader missed a small bleeding, but all hemorrhages were detected in the majority analysis (100% accuracy, CI lower boundary 86%, p = 0.002). ASPECTS majority analysis showed 90% accuracy (CI lower boundary 85%, p < 0.001). Sensitivity was 66% (individual readers 67%, 69%, and 76%), specificity was 97% (97%, 96%, 89%). Subjective and objective image quality were inferior to CT. Conclusion: In a small single-center cohort, dual-layer cone-beam CT showed non-inferior hemorrhage detection and ASPECTS accuracy to CT. Despite inferior image quality, the technique may be useful for stroke evaluation in the interventional suite. Trial Registration Number: NCT04571099 (clinicaltrials.gov). Prospectively registered 2020-09-04.