Sergey I. Kopylov

Sergey I. Kopylov

Auto-generated profile, based on publicly available information

Sergey I. Kopylov

Joint Institute for High Temperatures, Russian Academy of Science, Moscow, Russia

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2017 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
VAV. A. Altov
V. A. Altov
NBN. N. Balashov
N. N. Balashov
PDPavel Nikolaevich Degtyarenko
Pavel Nikolaevich Degtyarenko
SIS. S. Ivanov
S. S. Ivanov
SKS. I. Kopylov
S. I. Kopylov
VZV. V. Zheltov
V. V. Zheltov
This paper presents the results of calculation of ac HTS cables designs optimized by the values of hysteresis and eddy current losses. The superconducting elements of the cables are 2G HTS tapes. The program we developed and used allowed the variation of both the cable shape and its internal structure. There have been considered nonsectioned and sectioned cables having two variants of geometry-the axially symmetrical coaxial and extended rectangular cross-sectional shape. It has been shown that the internal structure optimization allows decreasing of ac losses in several times for both cross-sectional shapes. Due to the compensation of the perpendicular magnetic field component, the characteristics of flat three-phase cables turn out to be close of those with the axially symmetrical cross-sectional shape. In this case, the rectangular cross-sectional shape allows obtaining better mass, dimensional, and mechanical parameters and better cooling conditions of phases. The cables sectioning allows an essential reduction of ac losses. But, the latter is possible only when there is a uniform current distribution over the sections, i.e., at a very exact design calculation.

9 February 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
PDPavel Nikolaevich Degtyarenko
Pavel Nikolaevich Degtyarenko
AAAndrey Yu Arkangelsky
Andrey Yu Arkangelsky
NBNikolay N. Balashov
Nikolay N. Balashov
YBYurii L. Buyanov
Yurii L. Buyanov
VSVictor E. Sytnikov
Victor E. Sytnikov
VZVladimir V. Zheltov
Vladimir V. Zheltov
There had been considered optimized design versions of high-current three-phase HTS cables with 2G HTS tapes as current-carrying elements. Their characteristics (rms phase current 12 kA, line voltage 24 kV) conform to the parameters required for the first stage of the power transmission line from the generator to the first step-up transformer. Three types of cables are under consideration: one with screened phases and triaxial and flat, as well. The phase critical current value is taken 21 kA. For all the cables designs are given their exact geometric parameters together with the estimation of AC losses and HTS tapes consumption. It has been shown, that the optimization performed allows keeping up AC loses at a level acceptable for practical applications. The best design versions proposed have the losses within the range of 0.27–0.5 W/m, which are significantly lower than ones caused by the natural heat transfer into the cryostat – about 1–2 W/m, vs. its dimensions. All the cable types with one and the same design modification have an approximately equal level of losses. But triaxial and flat cables have an advantage in HTS tapes consumption.

23 July 2007 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
SKS. I. Kopylov
S. I. Kopylov
NBN. N. Balashov
N. N. Balashov
SIS. S. Ivanov
S. S. Ivanov
AVA. S. Veselovsky
A. S. Veselovsky
VVV. S. Vysotsky
V. S. Vysotsky
VZV. D. Zhemerikin
V. D. Zhemerikin
Various types of fault currents limiters have been proposed to reduce the fault currents in power transmission lines. The transformer type superconducting (SC) fault current limiter is one of them and has many advantages such as design flexibility. In normal operation mode the impedance is that of short-circuit transformer and has its minimum value. In the event of a load to fault an increase of the primary winding current causing a subsequent current increasing in the secondary SC winding (ring) and its quenching to the normal state. In this case the impedance turns to one in a no-load operation mode, i.e. is maximal performing the fault current limitation in the circuit to be protected. There has been investigated an effect of this sectioning of short-circuit SC windings or rings on the operation. A configuration of the transformer with symmetrical alternatively positioned disc windings is shown to be the optimal.

18 March 2015 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
PDF file
SKS. I. Kopylov
S. I. Kopylov
NBN. N. Balashov
N. N. Balashov
VZV. V. Zheltov
V. V. Zheltov
IKI. V. Krivetsky
I. V. Krivetsky
VSV. E. Sytnikov
V. E. Sytnikov
This paper introduces a new design solution for the high-power superconducting fault current limiter (SFCL). The device consists of concentric sections with a circular cross-section shape which are connected in series in such a way that the current in adjacent sections flows in mutually opposite directions. The analysis of efficiency of various designs and optimization of their geometry and dimensions was performed through numerical simulations. They show that the higher number of sections gives the ability to substantially decrease the amount of superconducting materials and to reduce hysteresis losses.