Céline D. Dürst

Céline D. Dürst

Auto-generated profile, based on publicly available information

Céline D. Dürst

Department of Basic Neurosciences and the Geneva University Neurocenter, Centre Médical Universitaire (CMU), University of Geneva, 1 Rue Michel Servet, 1211 Geneva, Switzerland

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 May 2018 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
Nordine HelassaNordine Helassa
Nordine Helassa
CDCéline D. Dürst
Céline D. Dürst
CCCatherine Coates
Catherine Coates
SKSilke Kerruth
Silke Kerruth
UAUrwa Arif
Urwa Arif
KTKatalin Torok
Katalin Torok
Significance: Excitatory synapses convert presynaptic action potentials into chemical signals that are sensed by postsynaptic glutamate receptors. To eavesdrop on synaptic transmission, genetically encoded fluorescent sensors for glutamate have been developed. However, even the best available sensors lag behind the very fast glutamate dynamics in the synaptic cleft. Here, we report the development of an ultrafast genetically encoded glutamate sensor, iGlu u , which allowed us to image glutamate clearance and synaptic depression during 100-Hz spike trains. We found that only boutons showing paired-pulse facilitation were able to rapidly recover from depression. Thus, presynaptic boutons act as frequency-specific filters to transmit select features of the spike train to specific postsynaptic cells.

17 October 2022 in Nature Communications
Verified
Journal Article
Open access
PDF file
CDCéline D. Dürst
Céline D. Dürst
JWJ. Simon Wiegert
J. Simon Wiegert
CSChristian Schulze
Christian Schulze
Nordine HelassaNordine Helassa
Nordine Helassa
KTKatalin Torok
Katalin Torok
TOThomas G. Oertner
Thomas G. Oertner
Information processing in the brain is controlled by quantal release of neurotransmitters, a tightly regulated process. From ultrastructural analysis, it is known that presynaptic boutons along single axons differ in the number of vesicles docked at the active zone. It is not clear whether the probability of these vesicles to get released (pves) is homogenous or also varies between individual boutons. Here, we optically measure evoked transmitter release at individual Schaffer collateral synapses at different calcium concentrations, using the genetically encoded glutamate sensor iGluSnFR. Fitting a binomial model to measured response amplitude distributions allowed us to extract the quantal parameters N, pves, and q. We find that Schaffer collateral boutons typically release single vesicles under low pves conditions and switch to multivesicular release in high calcium saline. The potency of individual boutons is highly correlated with their vesicular release probability while the number of releasable vesicles affects synaptic output only under high pves conditions.

15 April 2019 in Nature Protocols
Verified
Journal Article
Closed access
PDF file
CDCéline D. Dürst
Céline D. Dürst
JWJ. Simon Wiegert
J. Simon Wiegert
Nordine HelassaNordine Helassa
Nordine Helassa
SKSilke Kerruth
Silke Kerruth
CCCatherine Coates
Catherine Coates
TOThomas G. Oertner
Thomas G. Oertner

1 March 2019 in Journal of Biological Chemistry
Verified
Journal Article
Open access
PDF file
SKSilke Kerruth
Silke Kerruth
CCCatherine Coates
Catherine Coates
CDCéline D. Dürst
Céline D. Dürst
TOThomas G. Oertner
Thomas G. Oertner
KTKatalin Torok
Katalin Torok
Genetically encoded calcium indicators (GECIs) are useful reporters of cell-signaling, neuronal, and network activities. We have generated novel fast variants and investigated the kinetic mechanisms of two recently developed red-fluorescent GECIs (RGECIs), mApple-based jRGECO1a and mRuby-based jRCaMP1a. In the formation of fluorescent jRGECO1a and jRCaMP1a complexes, calcium binding is followed by rate-limiting isomerization. However, fluorescence decay of calcium-bound jRGECO1a follows a different pathway from its formation: dissociation of calcium occurs first, followed by the peptide, similarly to GCaMP-s. In contrast, fluorescence decay of calcium-bound jRCaMP1a occurs by the reversal of the on-pathway: peptide dissociation is followed by calcium. The mechanistic differences explain the generally slower off-kinetics of jRCaMP1a-type indicators compared with GCaMP-s and jRGECO1a-type GECI: the fluorescence decay rate of f-RCaMP1 was 21 s−1, compared with 109 s−1 for f-RGECO1 and f-RGECO2 (37 °C). Thus, the CaM–peptide interface is an important determinant of the kinetic responses of GECIs; however, the topology of the structural link to the fluorescent protein demonstrably affects the internal dynamics of the CaM–peptide complex. In the dendrites of hippocampal CA3 neurons, f-RGECO1 indicates calcium elevation in response to a 100 action potential train in a linear fashion, making the probe particularly useful for monitoring large-amplitude, fast signals, e.g. those in dendrites, muscle cells, and immune cells.

2 August 2020 in bioRxiv
Verified
Preprint
Open access
PDF file
CDCéline D. Dürst
Céline D. Dürst
JWJ. Simon Wiegert
J. Simon Wiegert
CSChristian Schulze
Christian Schulze
Nordine HelassaNordine Helassa
Nordine Helassa
KTKatalin Torok
Katalin Torok
TOThomas G. Oertner
Thomas G. Oertner
Information processing in the brain is controlled by quantal release of neurotransmitters, a tightly regulated process. From ultrastructural analysis, it is known that presynaptic boutons along single axons differ in the number of vesicles docked at the active zone. It is not clear whether the probability of these vesicles to get released ( p ves ) is homogenous or also varies between individual boutons. Here, we optically measure evoked transmitter release at individual Schaffer collateral synapses at different calcium concentrations, using the genetically encoded glutamate sensor iGluSnFR. Fitting a binomial model to measured response amplitude distributions allowed us to extract the quantal parameters N, p ves , a n d q . We find that Schaffer collateral boutons typically release single vesicles under low p ves conditions and switch to multivesicular release in high calcium saline. Analyzing the variability of quantal parameters, we conclude that the vesicular release probability rather than the number of readily releasable vesicles or their transmitter content determines the potency of individual boutons.

31 July 2025 in bioRxiv
Verified
Preprint
Open access
AAAbhi Aggarwal
Abhi Aggarwal
HBHeather A. Baker
Heather A. Baker
CDCéline D. Dürst
Céline D. Dürst
ICI-Wen Chen
I-Wen Chen
PCPablo de Chambrier
Pablo de Chambrier
ALAlexander W. Lohman
Alexander W. Lohman
Genetically encoded calcium indicators (GECIs) are vital tools for fluorescence-based visualization of neuronal activity with high spatial and temporal resolution. However, current highest-performance GECIs are predominantly green or red fluorescent, limiting multiplexing options and efficient excitation with fixed-wavelength femtosecond lasers operating at 1030 nm. Here, we introduce OCaMP (also known as O-GECO2), an orange fluorescent GECI engineered from O-GECO1 through targeted substitutions to improve calcium affinity while retaining the favorable photophysical properties of mOrange2. OCaMP exhibits improved two-photon cross-section, responsiveness, photostability, and calcium affinity relative to O-GECO1. In cultured neurons, zebrafish, and mouse cortex, OCaMP outperforms the red GECIs jRCaMP1a and jRGECO1a in sensitivity, kinetics, and signal-to-noise ratio. These properties establish OCaMP as a robust tool for high-fidelity neural imaging optimized for 1030 nm excitation and a compromise-free option within the spectral gap between existing green and red GECIs.