27 December 2021 in Journal of the American Medical Informatics Association
Problem lists represent an integral component of high-quality care. However, they are often inaccurate and incomplete. We studied the effects of alerts integrated into the inpatient and outpatient computerized provider order entry systems to assist in adding problems to the problem list when ordering medications that lacked a corresponding indication. We analyzed medication orders from 2 healthcare systems that used an innovative indication alert. We collected data at site 1 between December 2018 and January 2020, and at site 2 between May and June 2021. We reviewed random samples of 100 charts from each site that had problems added in response to the alert. Outcomes were: (1) alert yield, the proportion of triggered alerts that led to a problem added and (2) problem accuracy, the proportion of problems placed that were accurate by chart review. Alerts were triggered 131 134, and 6178 times at sites 1 and 2, respectively, resulting in a yield of 109 055 (83.2%) and 2874 (46.5%), P< .001. Orders were abandoned, for example, not completed, in 11.1% and 9.6% of orders, respectively, P<.001. Of the 100 sample problems, reviewers deemed 88% ± 3% and 91% ± 3% to be accurate, respectively, P = .65, with a mean of 90% ± 2%. Indication alerts triggered by medication orders initiated in the absence of a justifying diagnosis were useful for populating problem lists, with yields of 83.2% and 46.5% at 2 healthcare systems. Problems were placed with a reasonable level of accuracy, with 90% ± 2% of problems deemed accurate based on chart review.
30 January 2023 in Journal of the American Medical Informatics Association
Background: Studies examining the effects of computerized order entry (CPOE) on medication ordering errors demonstrate that CPOE does not consistently prevent these errors as intended. We used the Agency for Healthcare Research and Quality (AHRQ) Network of Patient Safety Databases (NPSD) to investigate the frequency and degree of harm of reported events that occurred at the ordering stage, characterized by error type. Materials and Methods: This was a retrospective observational study of safety events reported by healthcare systems in participating patient safety organizations from 6/2010 through 12/2020. All medication and other substance ordering errors reported to NPSD via common format v1.2 between 6/2010 through 12/2020 were analyzed. We aggregated and categorized the frequency of reported medication ordering errors by error type, degree of harm, and demographic characteristics. Results: A total of 12 830 errors were reported during the study period. Incorrect dose accounted for 3812 errors (29.7%), followed by incorrect medication 2086 (16.3%), and incorrect duration 765 (6.0%). Of 5282 events that reached the patient and had a known level of severity, 12 resulted in death, 4 resulted in severe harm, 45 resulted in moderate harm, 341 resulted in mild harm, and 4880 resulted in no harm. Conclusion: Incorrect dose and incorrect drug orders were the most commonly reported and harmful types of medication ordering errors. Future studies should aim to develop and test interventions focused on CPOE to prevent medication ordering errors, prioritizing wrong-dose and wrong-drug errors.
7 December 2023 in BMJ Quality & Safety
Studying near-miss errors is essential to preventing errors from reaching patients. When an error is committed, it may be intercepted (near-miss) or it will reach the patient; estimates of the proportion that reach the patient vary widely. To better understand this relationship, we conducted a retrospective cohort study using two objective measures to identify wrong-patient imaging order errors involving radiation, estimating the proportion of errors that are intercepted and those that reach the patient. This study was conducted at a large integrated healthcare system using data from 1 January to 31 December 2019. The study used two outcome measures of wrong-patient orders: (1) wrong-patient orders that led to misadministration of radiation reported to the New York Patient Occurrence Reporting and Tracking System (NYPORTS) (misadministration events); and (2) wrong-patient orders identified by the Wrong-Patient Retract-and-Reorder (RAR) measure, a measure identifying orders placed for a patient, retracted and rapidly reordered by the same clinician on a different patient (near-miss events). All imaging orders that involved radiation were extracted retrospectively from the healthcare system data warehouse. Among 293 039 total eligible orders, 151 were wrong-patient orders (3 misadministration events, 148 near-miss events), for an overall rate of 51.5 per 100 000 imaging orders involving radiation placed on the wrong patient. Of all wrong-patient imaging order errors, 2% reached the patient, translating to 50 near-miss events for every 1 error that reached the patient. This proportion provides a more accurate and reliable estimate and reinforces the utility of systematic measure of near-miss errors as an outcome for preventative interventions.
3 April 2023 in Journal of the American Medical Informatics Association
JKJerard Z Kneifati-Hayek
+1
A prior randomized controlled trial (RCT) showed no significant difference in wrong-patient errors between clinicians assigned to a restricted electronic health record (EHR) configuration (limiting to 1 record open at a time) versus an unrestricted EHR configuration (allowing up to 4 records open concurrently). However, it is unknown whether an unrestricted EHR configuration is more efficient. This substudy of the RCT compared clinician efficiency between EHR configurations using objective measures. All clinicians who logged onto the EHR during the substudy period were included. The primary outcome measure of efficiency was total active minutes per day. Counts were extracted from audit log data, and mixed-effects negative binomial regression was performed to determine differences between randomized groups. Incidence rate ratios (IRRs) were calculated with 95% confidence intervals (CIs). Among a total of 2556 clinicians, there was no significant difference between unrestricted and restricted groups in total active minutes per day (115.1 vs 113.3 min, respectively; IRR, 0.99; 95% CI, 0.93–1.06), overall or by clinician type and practice area.
6 July 2026 in Journal of Perinatal Medicine
Wrong-patient errors cause serious harm in newborns. These errors involve ordering and administering tests, procedures, medications, and breast milk to an unintended patient. Newborns receiving care in neonatal intensive care units (NICUs) are at particularly high risk. Although more distinct newborn naming conventions as recommended by the Joint Commission significantly reduce wrong-patient orders, name similarities among multiple-birth infants and truncation of differentiating information in some electronic health record (EHR) systems contribute to this persistent increased risk. Accordingly, novel newborn identifiers are urgently needed. We propose Pictographs – images that are appealing, recognizable, and appropriate – to serve as visual identifiers for newborns in NICUs. Pictographs are selected by caregivers, uploaded into the EHR, and displayed at bedside. As part of a multicenter randomized controlled trial assessing effectiveness of Pictographs to prevent wrong-patient order errors, we initially evaluated feasibility and acceptability of Pictographs at two study sites. Pictographs as novel visual identifiers for newborns in the NICU were generally well received by caregivers and clinicians, and the vast majority of caregivers selected a Pictograph for their infant(s), which was posted at the bedside and uploaded into the EHR. Ordering clinicians – the primary target of the intervention to prevent wrong-patient errors – recognized the potential for Pictographs to provide a visual cue when placing orders, particularly for multiple-birth infants. Here, we describe the rationale, implementation, framework, feasibility, usefulness, and acceptability of Pictographs among key stakeholders. If found effective for preventing wrong-patient errors, Pictographs could be adopted as a patient safety solution in hospitals worldwide.
26 October 2023 in The Joint Commission Journal on Quality and Patient Safety