26 November 2025 in IEEE Transactions on Instrumentation and Measurement
The power generation and loads of photovoltaic (PV) systems are inherently intermittent, periodic, and stochastic, resulting in non-stationary dynamic fluctuations in line currents. These dynamics have overlapping spectral features with DC series arcs, which increases the likelihood of false alarms and reduces the accuracy of arc detection. To address this problem, a DC series arc diagnosis method based on asymmetrical Gini impurity is proposed to reduce false alarm rate while ensuring accuracy. First, arc fault current data under various operating conditions are collected through experiments. To mitigate the impact of periodic fluctuations and enhance the detection of transient current changes, a multi-step differential processing method is employed. Second, the time-domain and frequency-domain features of arc faults are extracted from the differential signal to construct a high-dimensional feature vector. To reduce redundant features, the clustering algorithm is applied to identify and group features demonstrating analogous classification performance, and the asymmetric Gini impurity (AGI) is introduced to analyze feature significance. Finally, a random forest model based on AGI is utilized for DC series arc diagnosis. The experimental results demonstrate that the proposed method not only achieves high diagnosis accuracy and effectively reduces the false alarm rate, but also completes fault detection within 60 ms.