29 April 2024 in Nature Communications
Autologous skin grafting is a standard treatment for skin defects such as burns. No artificial skin substitutes are functionally equivalent to autologous skin grafts. The cultured epidermis lacks the dermis and does not engraft deep wounds. Although reconstituted skin, which consists of cultured epidermal cells on a synthetic dermal substitute, can engraft deep wounds, it requires the wound bed to be well-vascularized and lacks skin appendages. In this study, we successfully generate complete skin grafts with pluripotent stem cell-derived epidermis with appendages on p63 knockout embryos’ dermis. Donor pluripotent stem cell-derived keratinocytes encroach the embryos’ dermis by eliminating p63 knockout keratinocytes based on cell-extracellular matrix adhesion mediated cell competition. Although the chimeric skin contains allogenic dermis, it is engraftable as long as autologous grafts. Furthermore, we could generate semi-humanized skin segments by human keratinocytes injection into the amnionic cavity of p63 knockout mice embryos. Niche encroachment opens the possibility of human skin graft production in livestock animals.
28 June 2023 in Proceedings of the National Academy of Sciences
Patients with permanent hypoparathyroidism require lifelong replacement therapy to avoid life-threatening complications, The benefits of conventional treatment are limited, however. Transplanting a functional parathyroid gland (PTG) would yield better results. Parathyroid gland cells generated from pluripotent stem cells in vitro to date cannot mimic the physiological responses to extracellular calcium that are essential for calcium homeostasis. We thus hypothesized that blastocyst complementation (BC) could be a better strategy for generating functional PTG cells and compensating loss of parathyroid function. We here describe generation of fully functional PTGs from mouse embryonic stem cells (mESCs) with single-step BC. Using CRISPR-Cas9 knockout of Glial cells missing2 ( Gcm2 ), we efficiently produced aparathyroid embryos for BC. In these embryos, mESCs differentiated into endocrinologically mature PTGs that rescued Gcm2 −/− mice from neonatal death. The mESC-derived PTGs responded to extracellular calcium, restoring calcium homeostasis on transplantation into mice surgically rendered hypoparathyroid. We also successfully generated functional interspecies PTGs in Gcm2 −/− rat neonates, an accomplishment with potential for future human PTG therapy using xenogeneic animal BC. Our results demonstrate that BC can produce functional endocrine organs and constitute a concept in treatment of hypoparathyroidism.
11 February 2022 in Journal of Plastic Surgery and Hand Surgery
Acute hand edema often results in loss of fine hand motor activities, especially without appropriate care. There is still no reliable and easy to use method to measure hand edema. In this study, we tested a handheld three-dimensional (3D) scanner on plastic male and female hand models using a whole hand measuring method (WM) and a modified method (MM) which excluded fingers. We evaluated the intra-rater reliability and inter-rater reliability and compared the measured volumes to computed tomography (CT) findings. Statistical analysis showed that the 3D scan method was valid and reliable for both WM and MM methods. In WM, intra-rater and inter-rater reliability were 0.97 and 0.84, with 95% confidence interval (CI) of 0.87–1.00 and 0.61–0.94, respectively. In MM, intra-rater and inter-rater reliability were 0.96 and 0.83, with 95% CI of 0.84–1.00 and 0.61–0.94, respectively. In comparison to the CT, the differences between 3D scan and CT in the male model volumes were 30.35 ± 2.70 cm3 (mean ± standard deviation) for WM and 11.60 ± 2.07 cm3 for MM. In the female model, the differences were 18.92 ± 2.66 cm3 and 11.18 ± 2.35 cm3, respectively. In both models, MM was significantly more accurate than WM (p < 0.001). When used in a clinical case, the scanner recorded changes in actual volume through the course of treatment. This cost-effective handheld 3D camera can be a reliable tool for evaluating hand edema even in cases of acute injury.