Florian Meissner

Florian Meissner

Auto-generated profile, based on publicly available information

Florian Meissner

Darmstadt University of Applied Sciences

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2024 in Artificial Organs
Verified
Journal Article
Open access
FMFlorian Meissner
Florian Meissner
SSSophie Szvetics
Sophie Szvetics
MGMichelle Costa Galbas
Michelle Costa Galbas
MRMaximilian Russe
Maximilian Russe
DSDavid Schibilsky
David Schibilsky
WBWolfgang Bothe
Wolfgang Bothe
Background: In conventional left ventricular assist devices (LVAD), a separate outflow graft is sutured to the ascending aorta. Novel device designs may include a transventricular outflow cannula crossing the aortic valve (AV). While transversal ventricular dimensions are well investigated in patients with severe heart failure, little is known about the longitudinal dimensions. These dimensions are, however, particularly critical for the design and development of mechanical circulatory support (MCS) devices with transaortic outflow cannula. Methods: In an explorative retrospective cohort study at the University Medical Center Freiburg, Germany, the longitudinal cardiac dimensions of patients undergoing computed tomography angiography (CTA) before and, if available, after LVAD implantation were analyzed. Among others, the following dimensions were assessed: (a) apex to AV, (b) apex to mitral valve, (c) AV to sinotubular junction (STJ), (d) apex to STJ, (e) apex to brachiocephalic artery (BCA), and (f) AV to BCA. Results: In total, 44 LVAD patients (36 male, age 55.8 years, height 1.75 m) were included. The longitudinal cardiac dimensions were (a) 114.5 ± 12.1 mm, (b) 108.0 ± 12.4 mm, (c) 20.9 ± 2.9, (d) 135.4 ± 13.4 mm, (e) 206.0 ± 18.3, and (f) 91.5 ± 9.8 mm. Postoperatively, (a) and (b) decreased by 31.5% and 39.5%, respectively ( N = 14). Conclusions: Longitudinal cardiac dimensions may be reduced by up to 40% after LVAD implantation. A better knowledge of these dimensions and their postoperative alterations in LVAD patients may improve surgical planning and help to design MCS devices with transventricular outflow cannula.

21 September 2026 in Crisis and Risk Communication
Verified
Journal Article
Open access
DVDaniel Vogler
Daniel Vogler
LULinards Udris
Linards Udris
FMFlorian Meissner
Florian Meissner
At the moment, crises appear to be omnipresent, and it is often argued that we are living in a time of crisis, perhaps even a polycrisis (Tooze, 2022). Recent crises like the COVID-19 pandemic, the...

7 November 2023 in Circulation
Verified
Journal Article
Closed access
AOAnna Osypka
Anna Osypka
FMFlorian Meissner
Florian Meissner
DÖDeniz Öztürk
Deniz Öztürk
HVHeiko Vestner
Heiko Vestner
MGMichelle Costa Galbas
Michelle Costa Galbas
WBWolfgang Bothe
Wolfgang Bothe