Transcatheter aortic valve implantation (TAVI) has shown promising results in patients with severe aortic stenosis (AS) at high risk for conventional heart surgery. The safety and efficacy of transapical aortic valve implantation using the JenaValve™, a second-generation TAVI device, were evaluated. The system consists of a tested porcine root valve mounted on a nitinol stent with feeler-guided positioning and clip fixation on the diseased leaflets. This multicentre, prospective, single-arm study, conducted at seven German sites, enrolled 73 patients (mean age 83.1 ± 3.9), European System for Cardiac Operative Risk Evaluation (EuroSCORE) (28.4 ± 6.5%) of whom 67 patients underwent elective TAVI. Three sizes were used for annular diameters up to 23 mm (n = 21), 25 mm (n = 31) and 27 mm (n = 15). Clinical and echocardiographic evaluations were performed at baseline, post-procedure, discharge and 30 days, and also at 3, 6 and 12 months. The primary endpoint was all-cause mortality at 30 days. Secondary endpoints were procedural success, major adverse cardiac and cerebrovascular events and echocardiographic performance. TAVI with the JenaValve™ device was successful in 60 patients (procedural success rate 89.6%). The overall mortality at 30 days was 7.6%. Conversion to surgery was necessary in four patients (6%), two patients underwent valve-in-valve implantations (3%), one patient was withdrawn per protocol after conversion to TAVI using a balloon-expandable valve (1.5%) since the patient did not receive the study device. Perioperative stroke occurred in two cases (3%). Pacemaker implantation for new onset conduction disorders was necessary in six patients (9.1%). No ostial coronary obstructions were seen. Post-procedure TAVI resulted in favourable reduction of mean transvalvular gradients (40.6 ± 15.9 vs. 10.0 ± 7.2 mmHg, P < 0.0001) and increase in valve opening area (0.7 ± 0.2 vs. 1.7 ± 0.6 cm², P < 0.0001). The majority of successfully treated patients revealed no or minimal paravalvular aortic regurgitation (86.4%); none of the patients had severe post-procedural regurgitation (>2+). Transapical JenaValve™ implantation was safe and effective in the treatment of severe AS in elderly patients at high risk for surgery. Active clip fixation on the native leaflets and anatomically correct feeler-guided positioning led to good functionality and prevented ostial coronary impairment. Implantation without the need for rapid pacing prevented haemodynamic compromise during valve implantation.
1 January 2012 in The Journal of Thoracic and Cardiovascular Surgery
Objectives Biological prostheses for surgical aortic valve replacement (sAVR) are increasingly being considered in patients < 60 years of age. Likely, preserving the option of performing a transcatheter valve-in-valve (ViV) procedure in cases of structural valve deterioration has contributed to this development. We assessed the use pattern in sAVR over an 11-year period. Methods From 2002 through 2012, a total of 3,172 patients underwent sAVR at our center. Results Mean age was 70.4 ± 10.6 years and mortality was 1.9%. From 2002 to 2012, mean manufacturer given valve size increased from 22.8 ± 1.7 to 23.9 ± 2.0 mm (p < 0.001). Mean true internal diameter and effective orifice area increased from 19.6 to 20.3 mm (p = 0.027) and 1.41 to 1.56 cm2 (p < 0.001), respectively. Use of mechanical valves decreased from 10.9 to 1.8% (p < 0.001), and patients were younger in 2012 than in 2002 (52.8 ± 16.5 vs. 41.0 ± 14.3 years; p = 0.028). Conclusion Profound change of use pattern in sAVR was observed as indication for biological prostheses became more liberal. Larger prostheses were implanted during the observational period. Especially in younger patients, optimal sizing is essential to preserve the option for subsequent ViV procedures. * Both the authors contributed equally to this work.