1 July 2006 in Operative Dentistry
Clinical Relevance: Both forms of sodium ascorbate (hydrogel and solution) can significantly increase the bond strength of resin composite to enamel after bleaching.
1 October 2010 in Photomedicine and Laser Surgery
Objective:
This study compared the effects of three mechanical surface treatments, including diamond bur, air-abrasion, and Er, Cr: YSGG laser on the repair bond strength of a laboratory composite resin. Background Data: A proper bonding must be created between the existing composite and the new one for successful repair.
Materials and Methods:
Sixty cylindrical specimens of a laboratory composite resin (Gradia) were prepared and randomly divided into four groups ( n = 15). Groups 2–4 were treated with diamond bur, air-abrasion, and Er, Cr: YSGG laser, respectively; group 1 was the control group, without any mechanical surface treatment. The topographical effects of different mechanical surface treatments were characterized by atomic force microscope. Silane and a bonding agent (Single Bond) were used in all of the groups before adding a direct resin composite. Then, the specimens were subjected to a shear bond strength test. Failure modes were evaluated under a stereomicroscope. All data were analyzed by one-way ANOVA and Tukey test at a significance level of p < 0.05.
Results:
There were statistically significant differences in bond strengths between the groups ( p < 0.0005). Differences in bond strengths between group 1 and the other groups were significant ( p < 0.0005). Furthermore, there were significant differences in bond strengths between group 2 and groups 3 and 4 ( p < 0.0005), while the bond strength differences between groups 3 and 4 were not significant.
Conclusion:
Based on the results of this study, Er, Cr: YSGG laser was confirmed to be as effective as air-abrasion for laboratory composite repair.
1 January 2010 in Indian Journal of Dental Research
ZHZahra Norooz Zadeh Helali
Zahra Norooz Zadeh Helali
Aim: This study compared the effects of hydrogel and solution forms of sodium ascorbate (SA) with two different application times on bracket bond strength subsequent to bleaching. Materials and Methods: A total of 72 sound premolars were randomly divided into six groups (n = 12): An unbleached control group (group one) and five experimental groups of carbamide peroxide. Specimens in group two were bonded immediately after bleaching; specimens in groups three and four were bleached, then treated with SA solution for ten minutes and three hours, respectively, and then bonded. In groups five and six, SA hydrogel was used and the specimens were prepared similar to groups three and four, respectively. Following debonding, bond strengths were recorded in MPa. To evaluate the amount of resin left on the enamel surfaces, adhesive remnant index (ARI) scores were used. Statistical Analysis: The bond strength data were analyzed with ANOVA and pairwise comparisons were made by Tukey test. The ARI data were subjected to Kruskal-Wallis test and two-by-two comparisons were made by the Mann-Whitney U test. Results: There were significant differences in bond strengths between the groups ( P < 0.0005). However, the differences between groups three, four, five and six were not significant. Furthermore, there were no significant differences between group one and groups four and six, whereas the differences between the other groups were significant ( P < 0.05). Regarding ARI, there were significant differences among the groups ( P = 0.004). Conclusion: Bleaching significantly decreased the bracket bond strength. Compromised bonding was reversed with a three-hour application of both forms of SA.
1 February 2008 in The Journal of Contemporary Dental Practice
Aim: The aim of this study was to compare the effects of solution and different sodium ascorbate hydrogels on dentin-resin composite shear bond strength subsequent to a bleaching procedure with 10% carbamide peroxide. Methods and Materials: Sixty buccal dentin surfaces obtained from intact human third molars were randomly divided into five groups (n=12). Dentin surfaces received different treatments: (1) no treatment; (2) bleaching (10% carbamide peroxide gel); (3) bleaching + 10% sodium ascorbate solution; (4) bleaching + 10% sodium ascorbate hydrogel, and (5) bleaching + 20% sodium ascorbate hydrogel. Dentin surfaces were bonded with Single Bond™ and restored with a composite (Z100). The samples were tested for shear bond strengths. Data was analyzed using analysis of variance (ANOVA) and Tukey tests. Results: Significantly higher bond strengths were observed subsequent to treatment with hydrogel and solution forms of sodium ascorbate (p<0.05). No significant differences were demonstrated between different forms of sodium ascorbate preparations. In addition, no significant differences were observed among groups with antioxidant treatment (Groups 3, 4, and 5) and Group 1 (no treatment). Conclusion: Reduced bond strength to bleached dentin can be amended by the use of sodium ascorbate as an antioxidant. Clinical Significance: Both hydrogel and solution forms of sodium ascorbate can significantly improve the reduced bond strength of resin composite to dentin subsequent to a bleaching procedure with 10% carbamide peroxide. Citation: Kimyai S, Valizadeh H. Comparison of the Effect of Hydrogel and a Solution of Sodium Ascorbate on Dentin-composite Bond Strength After Bleaching. J Contemp Dent Pract 2008 February;(9)2:105-112.
1 February 2013 in The Journal of Contemporary Dental Practice
Aim: This study evaluated the effect of three different contamination removal methods on bond strength of one-step self-etching adhesive to dentin contaminated with an aluminum chloride hemostatic agent. Materials and methods: One hundred noncarious adult molars were used in this study; 2-mm-thick dentin disks were prepared and randomly assigned to 5 groups (n = 20). Group I: control; group II: hemostatic agent-contaminated; group III: hemostatic agent-contaminated and rinsing with water; group IV: hemostatic agent-contaminated and ethylene diamine tetraacetic acid (EDTA) application; and group V: hemostatic agent-contaminated and phosphoric acid application. Clearfil S3 Bond was used to bond composite to dentin surfaces. Subsequent to adding composite cylinders the shear bond strength test was performed. Data were analyzed by one-way ANOVA and Tukey test. Two additional specimens from each group were prepared and evaluated under scanning electron microscope (SEM). Results: There were statistically significant differences in bond strength among the groups (p < 0.001). In two-by-two comparisons statistically significant differences were observed in bond strength values between all the groups (p < 0.001) except for groups I and IV (p = 0.933). Conclusion: Aluminum chloride hemostatic agent adversely affected the bond strength of self-etch adhesive to dentin. However, application of EDTA increased the bond strength to the level of normal dentin. Clinical significance: EDTA and phosphoric acid removed aluminum chloride hemostatic agent contamination of dentin surfaces. However, unlike EDTA phosphoric acid failed to increase the bond strength of self-etch adhesive to dentin to the level of the control group. How to cite this article: Ajami AA, Kahnamoii MA, Kimyai S, Oskoee SS, Pournaghi-Azar F, Bahari M, Firouzmandi M. Effect of Three Different Contamination Removal Methods on Bond Strength of a Self-etching Adhesive to Dentin Contaminated with an Aluminum Chloride Hemostatic Agent. J Contemp Dent Pract 2013;14(1):26-33.
1 January 2012 in Medicina Oral Patología Oral y Cirugia Bucal
The effect of 15% carbamide peroxide bleaching gel on color stability and surface topography of a giomer and a microfilled composite resin was evaluated in the present in vitro study. Forty discs measuring 10 mm in diameter and 1 mm in thickness were prepared from a giomer and a microfilled composite resin. Each material yielded 20 discs with completely smooth surfaces. Then a spectrophotometer was used to measure L* (lightness), a* (redness, greenness) and b* (blueness, yellowness) color coordinates of all the discs. Subsequently, the specimens were subjected to 15% carbamide peroxide bleaching gel. After measuring the color coordinates once again, color changes (ΔE*) were calculated by the CIELAB system. Four specimens from each material (two specimens before bleaching agent application and two specimens thereafter) were viewed under an atomic force microscope (AFM) for surface topography evaluation. Data were analyzed by Mann-Whitney U and Kruskal-Wallis tests at α=0.05. There were no statistically significant differences in color changes (ΔE*) between the two materials (P>0.05). In addition, no significant differences were detected in surface roughness between composite resin and giomer discs before and after bleaching (P>0.05 for both). However, in both materials the differences in surface roughness were significant before and after bleaching procedures (P<0.001). Based on the results of the present study it was concluded that 15% carbamide peroxide does not induce clinically detectable color changes in composite resin and giomer despite an increase in surface roughness.