1 December 2019 in Annals of Nuclear Energy
1 April 2018 in Journal of Environmental Radioactivity
1 May 2016 in Nuclear Engineering and Design
12 December 2019 in Radiation Protection Dosimetry
Decommissioning of nuclear building structures usually leads to large amounts of low-level radioactive waste. Using a reliable method to determine the contamination depth, it is indispensable prior to the start of decontamination works and for minimising the radioactive waste volume and the total workload. This paper deals with the possibilities of determination of depth distribution of activity of 137Cs and depth of contamination. The method described in this paper is based on concrete core sampling and laboratory gamma-ray spectroscopy measurements.
10 December 2019 in Radiation Protection Dosimetry
An important factor in calculation of quantities describing the radiation situation is the selection of a calculation code. In this article, the radiation situation for selected geometries with multilayer shields was judged. Calculations were carried out using deterministic code VISIPLAN and stochastic code MCNP5. Inter-comparison of calculations with experiment was done. The aim was to compare and evaluate the results achieved by the measurements and calculations, to analyze the methods of individual calculation codes and to discuss deviations in the results. Comparison of MCNP calculations and FH40G measurements shows that the relative deviations were ±20% for each shielding configuration. The results obtained by VISIPLAN code are strongly dependent on the selected buildup factor (BUF). However, in almost all cases, it appears that using Broder’s formula to calculate BUF for multilayer shields is a good approach to refine the calculation.