Riccardo Tiberi

Riccardo Tiberi

Auto-generated profile, based on publicly available information

Riccardo Tiberi

Stroke Research, Vall d’Hebron Research Institute, Barcelona, Spain

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2023 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
JLJiahui Li
Jiahui Li
RTRiccardo Tiberi
Riccardo Tiberi
PCPere Canals
Pere Canals
DVDaniel Vargas
Daniel Vargas
OCOscar Castaño
Oscar Castaño
MRMarc Ribó
Marc Ribó
Background A repeated number of passes during mechanical thrombectomy leads to worse clinical outcomes in acute ischemic stroke. Initial experiences with the simultaneous double stent-retriever (double-SR) technique as the first-line treatment showed promising safety and efficacy results. Objective To characterize the potential benefits of using the double-SR as first-line technique as compared with the traditional single-SR approach. Methods Three types of clot analogs (soft, moderately stiff, and stiff) were used to create terminal internal carotid artery (T-ICA=44) and middle cerebral artery (MCA=88) occlusions in an in vitro neurovascular model. Sixty-six cases were randomized into each treatment arm: single-SR or double-SR, in combination with a 0.071" distal aspiration catheter. A total of 132 in vitro thrombectomies were performed. Primary endpoints were the rate of first-pass recanalization (%FPR) and procedural-related distal emboli. Results FPR was achieved in 42% of the cases. Overall, double-SR achieved a significantly higher %FPR than single-SR (52% vs 33%, P=0.035). Both techniques showed similar %FPR in T-ICA occlusions (single vs double: 23% vs 27%, P=0.728). Double-SR significantly outperformed single-SR in MCA occlusions (63% vs 38%, P=0.019), most notably in saddle occlusions (64% vs 14%, P=0.011), although no significant differences were found in single-branch occlusions (64% vs 50%, P=0.275). Double-SR reduced the maximal size of the clot fragments migrating distally (Feret diameter=1.08±0.65 mm vs 2.05±1.14 mm, P=0.038). Conclusions This randomized in vitro evaluation demonstrates that the front-line double-SR technique is more effective than single-SR in achieving FPR when treating MCA bifurcation occlusions that present saddle thrombus.

5 May 2023 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
JLJiahui Li
Jiahui Li
RTRiccardo Tiberi
Riccardo Tiberi
PBPervinder Bhogal
Pervinder Bhogal
JBJan-Hendrik Buhk
Jan-Hendrik Buhk
DBDaniel Behme
Daniel Behme
MRMarc Ribó
Marc Ribó
Background: Repeated number of passes, clot fragmentation, and distal embolization during mechanical thrombectomy (MT) lead to worse clinical outcomes in acute ischemic stroke. This study aimed to assess the recanalization and embolic outcomes of different stent-retrievers (SRs): open-tip SR (Solitaire X 6×40 mm), closed-tip SR (EmboTrap II 5×33 mm), and filter-tip SR (NeVa NET 5.5×37 mm). Methods: Stiff-friable clot analogs were used to create middle cerebral artery (M1-MCA) occlusions in a benchtop model. After occlusion, experiments were randomized into one of the three treatment arms. The thrombectomy technique consisted of retrieving the SR into a balloon guide catheter under proximal flow arrest and continuous aspiration. A total of 150 single-attempt cases were performed (50 cases/treatment arm). Distal emboli (>100 µm) were collected and analyzed after each experiment. Results: Filter-tip SR achieved a non-significantly higher first-pass recanalization rate than open-tip SR and closed-tip SR (66% vs 48% vs 44%; P=0.064). Filter-tip SR prevented clot fragments>1 mm from embolizing distal territories in 44% of cases, compared with 16% in open-tip SR and 20% in closed-tip (P=0.003). There were no significant differences between treatment arms in terms of total emboli count (open-tip=19.2±13.1, closed-tip=19.1±10.7, filter-tip=17.2±13.0; P=0.660). Nonetheless, the number of large emboli (>1 mm) and total area of emboli were significantly lower in the filter-tip arm (n=0.88±1.2, A=2.06±1.85 mm2) than in the closed-tip arm (n=2.34±3.38, A=4.06±4.80 mm2; P1 mm) that embolize distally during an MT procedure, which in turn may increase the chances of first-pass complete recanalization.

14 September 2023 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
MJMagda Jablonska
Magda Jablonska
JLJiahui Li
Jiahui Li
RTRiccardo Tiberi
Riccardo Tiberi
PCPere Canals
Pere Canals
SGSantiago Ortega Gutierrez
Santiago Ortega Gutierrez
MRMarc Ribó
Marc Ribó
BACKGROUND AND PURPOSE: Mechanical thrombectomy has become a first-line treatment for acute ischemic stroke. Several techniques combining stent retrievers and distal aspiration catheters have been described. We aimed to characterize the efficacy of 2 commonly used techniques according to clot characteristics. MATERIALS AND METHODS: Soft (mean stiffness = 95.77 [SD, 5.80] kPa) or stiff (mean stiffness = 205.63 [SD, 6.70] kPa) clots (3 × 10 mm and 2 × 10 mm, respectively) were embolized to the distal M1 segment of the MCA in an in vitro model. The technique was randomly allocated (1:1): stent retriever assisted vacuum-locked extraction (SAVE) versus complete retraction (Solumbra). The primary end point was the percentage of first-pass recanalization. Secondary end points were periprocedural distal embolization measures. RESULTS: A total of 130 mechanical thrombectomies were performed (50 for soft clots and 15 for stiff clots per arm). Overall, the rate of first-pass recanalizaton was 35% with Solumbra and 15% with SAVE (P < .01). For stiff clots, the first-pass recanalizaton was equal for both methods (27%; P = 1.00). With soft clots, the first-pass recanalizaton was higher with Solumbra (38%) than with SAVE (12%; P < .01). When we used soft clots, the maximum embolus size (mean, 1.19 [SD, 0.9] mm versus 2.16 [SD, 1.48] mm; P < .01) and total area of emboli (mean, 1.82 [SD, 2.73] versus 3.34 [SD, 3.2]; P = .01) were also lower with Solumbra than with SAVE. CONCLUSIONS: Clot characteristics may influence the efficacy of the thrombectomy technique. In occlusions caused by soft clots, complete retrieval into the distal aspiration catheters achieved higher rates of first-pass recanalizaton and lower embolization.

30 August 2023 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
MRManuel Requena
Manuel Requena
JLJiahui Li
Jiahui Li
RTRiccardo Tiberi
Riccardo Tiberi
PCPere Canals
Pere Canals
MGMarta Olive Gadea
Marta Olive Gadea
MRMarc Ribó
Marc Ribó
Background Collateral blood supply of distal vessels has been linked to clinical outcome, infarct volume and recanalization rates in patients with large vessel occlusion. Our study aimed to explore the effects of catheterization during mechanical thrombectomy in collaterals. Methods We quantified the flow diversion effect secondary to arterial occlusions in an in vitro model which was connected in a flow-loop setup with a saline reservoir and a pump supplying pulsatile flow. Clot analogs were embolized to the middle cerebral artery (MCA) M1 or M2 segments. We used the same model with a clamped anterior communicating artery (AComA) to simulate its absence. An ultrasound flow sensor was placed at the vessel of interest. Flow rates and pressures were evaluated according to the following catheter locations: baseline (1) before and (2) after the occlusion; (3) 8F guiding catheter at the internal carotid artery (ICA) bulb; (4) at the cavernous segment; (5) at the cavernous segment a 0.071” distal access catheter at proximal M1; (6) 8F balloon guide catheter inflated. Results Collateral blood flow measured at distal anterior cerebral artery (ACA) (M1-MCA occlusion) and M2-MCA (M2-MCA occlusion) was progressively reduced as catheters were advanced through the ICA and MCA. In the lacking AComA model, the flow was further diminished as compared with the model with a patent AComA. Conclusion Our in vitro study showed a progressive reduction of collateral blood flow due to the advance of catheters during mechanical thrombectomy.

25 April 2024 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
ATAlejandro Tomasello
Alejandro Tomasello
DHDavid Hernández
David Hernández
JLJiahui Li
Jiahui Li
RTRiccardo Tiberi
Riccardo Tiberi
EREila Rivera
Eila Rivera
MRMarc Ribó
Marc Ribó
BACKGROUND AND PURPOSE: Endovascular robotic devices may enable experienced neurointerventionalists to remotely perform endovascular thrombectomy. This study aimed to assess the feasibility, safety, and efficacy of robot-assisted endovascular thrombectomy compared with manual procedures by operators with varying levels of experience, using a 3D printed neurovascular model. MATERIALS AND METHODS: M1 MCA occlusions were simulated in a 3D printed neurovascular model, linked to a CorPath GRX robot in a biplane angiography suite. Four interventionalists performed manual endovascular thrombectomy (n = 45) and robot-assisted endovascular thrombectomy (n = 37) procedures. The outcomes included first-pass recanalization (TICI 2c–3), the number and size of generated distal emboli, and procedural length. RESULTS: A total of 82 experimental endovascular thrombectomies were conducted. A nonsignificant trend favoring the robot-assisted endovascular thrombectomy was observed in terms of final recanalization (89.2% versus manual endovascular thrombectomy, 71.1%; P = .083). There were no differences in total mean emboli count (16.54 [SD, 15.15] versus 15.16 [SD, 16.43]; P = .303). However, a higher mean count of emboli of > 1 mm was observed in the robot-assisted endovascular thrombectomy group (1.08 [SD, 1.00] versus 0.49 [SD, 0.84]; P = .001) compared with manual endovascular thrombectomy. The mean procedural length was longer in robot-assisted endovascular thrombectomy (6.43 [SD, 1.71] minutes versus 3.98 [SD, 1.84] minutes; P < .001). Among established neurointerventionalists, previous experience with robotic procedures did not influence recanalization (95.8% were considered experienced; 76.9% were considered novices; P = .225). CONCLUSIONS: In a 3D printed neurovascular model, robot-assisted endovascular thrombectomy has the potential to achieve recanalization rates comparable with those of manual endovascular thrombectomy within competitive procedural times. Optimization of the procedural setup is still required before implementation in clinical practice.

6 June 2024 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
MJMagda Jablonska
Magda Jablonska
JLJiahui Li
Jiahui Li
RTRiccardo Tiberi
Riccardo Tiberi
EBEsref Alperen Bayraktar
Esref Alperen Bayraktar
CBCem Bilgin
Cem Bilgin
MRMarc Ribó
Marc Ribó
BACKGROUND AND PURPOSE: Mechanical thrombectomy is a fundamental intervention for acute ischemic stroke treatment. While conventional techniques are effective, cyclic aspiration (CyA) shows potential for better recanalization rates. We aim to investigate factors affecting CyA and compare them with static aspiration (StA). MATERIALS AND METHODS: StA setup consisted of an aspiration pump connected to pressure transducer. CyA was tested with five subsequent iterations: single solenoid valve with air+saline (1) or saline alone (2) as aspiration medium; two solenoid valves with air+saline (3) as aspiration medium; complete air removal and saline feeding (4); pressurized saline feeding (5). To assess the efficacy of clot ingestion, the pressure transducer was replaced with a distal aspiration catheter. Moderately stiff clot analogs (15 mm) were used to investigate the ingestion quantified as clot relative weight loss. Additionally, the aspiration flow rate was assessed for each setup. RESULTS: With CyA setup 1, the amplitude of the achieved negative pressure waves declined with increasing frequencies but progressively increased with each subsequent iteration, achieving a maximum amplitude of 81 kPa for setup 5 at 1Hz. Relative clot weight loss was significantly higher with setup 5 at 5Hz than with StA (100% vs. 37,8%; p=0.05). Aspiration flow rate was lower with CyA than with StA (setup 5 at 5Hz: 199,8ml/min vs. StA: 311ml/min; p<0.01). CONCLUSIONS: Cyclic aspiration with the appropriate setup may represent an encouraging innovation in mechanical thrombectomy, offering a promising pathway for improving efficacy in clot ingestion and recanalization. The observed benefits warrant confirmation in a clinical setting. ABBREVIATIONS: CyA -cyclic aspiration, StA – static aspiration, FPR -first pass reperfusion, MT -mechanical thrombectomy, DAC -distal aspiration catheter, LVO -large vessel occlusion.