6 April 2004 in Physical Review Letters
The puzzle of how time-reversible microscopic equations of mechanics lead to the time-irreversible macroscopic equations of thermodynamics has been a paradox since the days of Boltzmann. Boltzmann simply sidestepped this enigma by stating “as soon as one looks at bodies of such small dimension that they contain only very few molecules, the validity of this theorem [the second law of thermodynamics and its description of irreversibility] must cease.” Today we can state that the transient fluctuation theorem (TFT) of Evans and Searles is a generalized, second-law-like theorem that bridges the microscopic and macroscopic domains and links the time-reversible and irreversible descriptions. We apply this theorem to a colloidal particle in an optical trap. For the first time, we demonstrate the TFT in an experiment and show quantitative agreement with Langevin dynamics.
13 April 2014 in Nature Photonics
28 April 2005 in Physical Review E
The fluctuation theorem (FT) quantifies the probability of second law violations in small systems over short time scales. While this theorem has been experimentally demonstrated for systems that are perturbed from an initial equilibrium state, there are a number of studies suggesting that the theorem applies asymptotically in the long time limit to systems in a nonequilibrium steady state. The asymptotic application of the FT to such nonequilibrium steady states has been referred to in the literature as the steady-state fluctuation theorem (or SSFT). In this paper, we demonstrate experimentally the application of the FT to nonequilibrium steady states, using a colloidal particle localized in a translating optical trap. Furthermore, we show, for this colloidal system, that the FT holds under nonequilibrium steady states for all time, and not just in the long time limit, as in the SSFT.
1 January 2014 in Computer Physics Communications
20 December 2012 in Optics Express
We demonstrate the use of an extended, optically trapped probe that is capable of imaging surface topography with nanometre precision, whilst applying ultra-low, femto-Newton sized forces. This degree of precision and sensitivity is acquired through three distinct strategies. First, the probe itself is shaped in such a way as to soften the trap along the sensing axis and stiffen it in transverse directions. Next, these characteristics are enhanced by selectively position clamping independent motions of the probe. Finally, force clamping is used to refine the surface contact response. Detailed analyses are presented for each of these mechanisms. To test our sensor, we scan it laterally over a calibration sample consisting of a series of graduated steps, and demonstrate a height resolution of ∼ 11 nm. Using equipartition theory, we estimate that an average force of only ∼ 140 fN is exerted on the sample during the scan, making this technique ideal for the investigation of delicate biological samples.
7 June 2011 in Nanotechnology
We present an imaging technique using an optically trapped cigar-shaped probe controlled using holographic optical tweezers. The probe is raster scanned over a surface, allowing an image to be taken in a manner analogous to scanning probe microscopy (SPM), with automatic closed loop feedback control provided by analysis of the probe position recorded using a high speed CMOS camera. The probe is held using two optical traps centred at least 10 µm from the ends, minimizing laser illumination of the tip, so reducing the chance of optical damage to delicate samples. The technique imparts less force on samples than contact SPM techniques, and allows highly curved and strongly scattering samples to be imaged, which present difficulties for imaging using photonic force microscopy. To calibrate our technique, we first image a known sample--the interface between two 8 µm polystyrene beads. We then demonstrate the advantages of this technique by imaging the surface of the soft alga Pseudopediastrum. The scattering force of our laser applied directly onto this sample is enough to remove it from the surface, but we can use our technique to image the algal surface with minimal disruption while it is alive, not adhered and in physiological conditions. The resolution is currently equivalent to confocal microscopy, but as our technique is not diffraction limited, there is scope for significant improvement by reducing the tip diameter and limiting the thermal motion of the probe.