Pulsatile blood flow through the cavities of the heart and great vessels is time-varying and multidirectional. Access to all regions, phases and directions of cardiovascular flows has formerly been limited. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) has enabled more comprehensive access to such flows, with typical spatial resolution of 1.5×1.5×1.5 – 3×3×3 mm3, typical temporal resolution of 30–40 ms, and acquisition times in the order of 5 to 25 min. This consensus paper is the work of physicists, physicians and biomedical engineers, active in the development and implementation of 4D Flow CMR, who have repeatedly met to share experience and ideas. The paper aims to assist understanding of acquisition and analysis methods, and their potential clinical applications with a focus on the heart and greater vessels. We describe that 4D Flow CMR can be clinically advantageous because placement of a single acquisition volume is straightforward and enables flow through any plane across it to be calculated retrospectively and with good accuracy. We also specify research and development goals that have yet to be satisfactorily achieved. Derived flow parameters, generally needing further development or validation for clinical use, include measurements of wall shear stress, pressure difference, turbulent kinetic energy, and intracardiac flow components. The dependence of measurement accuracy on acquisition parameters is considered, as are the uses of different visualization strategies for appropriate representation of time-varying multidirectional flow fields. Finally, we offer suggestions for more consistent, user-friendly implementation of 4D Flow CMR acquisition and data handling with a view to multicenter studies and more widespread adoption of the approach in routine clinical investigations.
22 October 2012 in Journal of Magnetic Resonance Imaging
Purpose: To evaluate an improved image acquisition and data‐processing strategy for assessing aortic vascular geometry and 3D blood flow at 3T.Materials and Methods: In a study with five normal volunteers and seven patients with known aortic pathology, prospectively ECG‐gated cine three‐dimensional (3D) MR velocity mapping with improved navigator gating, real‐time adaptive k‐space ordering and dynamic adjustment of the navigator acceptance criteria was performed. In addition to morphological information and three‐directional blood flow velocities, phase‐contrast (PC)‐MRA images were derived from the same data set, which permitted 3D isosurface rendering of vascular boundaries in combination with visualization of blood‐flow patterns.Results: Analysis of navigator performance and image quality revealed improved scan efficiencies of 63.6% ± 10.5% and temporal resolution (<50 msec) compared to previous implementations. Semiquantitative evaluation of image quality by three independent observers demonstrated excellent general image appearance with moderate blurring and minor ghosting artifacts. Results from volunteer and patient examinations illustrate the potential of the improved image acquisition and data‐processing strategy for identifying normal and pathological blood‐flow characteristics.Conclusion: Navigator‐gated time‐resolved 3D MR velocity mapping at 3T in combination with advanced data processing is a powerful tool for performing detailed assessments of global and local blood‐flow characteristics in the aorta to describe or exclude vascular alterations. J. Magn. Reson. Imaging 2007.
1 January 2012 in Journal of Cardiovascular Magnetic Resonance
The purpose of this study was to investigate 3D flow patterns and vessel wall parameters in patients with dilated ascending aorta, age-matched subjects, and healthy volunteers. Thoracic time-resolved 3D phase contrast CMR with 3-directional velocity encoding was applied to 33 patients with dilated ascending aorta (diameter ≥40 mm, age=60±16 years), 15 age-matched normal controls (diameter ≤37 mm, age=68±7.5 years) and 15 young healthy volunteers (diameter ≤30 mm, age=23±2 years). 3D blood flow was visualized and flow patterns were graded regarding presence of supra-physiologic-helix and vortex flow using a semi-quantitative 3-point grading scale. Blood flow velocities, regional wall shear stress (WSS), and oscillatory shear index (OSI) were quantified. Incidence and strength of supra-physiologic-helix and vortex flow in the ascending aorta (AAo) was significantly higher in patients with dilated AAo (16/33 and 31/33, grade 0.9±1.0 and 1.5±0.6) than in controls (2/15 and 7/15, grade 0.2 ± 0.6 and 0.6 ± 0.7, P<.05) or healthy volunteers (1/15 and 0/15, grade 0.1 ± 0.3 P<.05). Greater strength of the ascending aortic helix and vortex flow were associated with significant differences in AAo diameters (P<.05). Peak systolic WSS in the ascending aorta and aortic arch was significantly lower in patients with dilated AAo (P<.0157-.0488). AAo diameter positively correlated to time to peak systolic velocities (r=0.30-0.53, P<.04), OSI (r=0.33-0.49, P<0.02) and inversely correlated to peak systolic WSS (r=0.32-0.40, P<.03). Peak systolic WSS was significantly lower in AAo aneurysms at the right and outer curvature within the AAo and proximal arch (P<.01-.05). Increase in AAo diameter is significantly correlated with the presence and strength of supra-physiologic-helix and vortex formation in the AAo, as well with decrease in systolic WSS and increase in OSI.
29 March 2011 in Journal of Magnetic Resonance Imaging
Purpose: To determine the precision and accuracy of hepatic fat‐fraction measured with a chemical shift‐based MRI fat‐water separation method, using single‐voxel MR spectroscopy (MRS) as a reference standard.Materials and Methods: In 42 patients, two repeated measurements were made using a T1‐independent, T‐corrected chemical shift‐based fat‐water separation method with multi‐peak spectral modeling of fat, and T2‐corrected single voxel MR spectroscopy. Precision was assessed through calculation of Bland‐Altman plots and concordance correlation intervals. Accuracy was assessed through linear regression between MRI and MRS. Sensitivity and specificity of MRI fat‐fractions for diagnosis of steatosis using MRS as a reference standard were also calculated.Results: Statistical analysis demonstrated excellent precision of MRI and MRS fat‐fractions, indicated by 95% confidence intervals (units of absolute percent) of [−2.66%,2.64%] for single MRI ROI measurements, [−0.81%,0.80%] for averaged MRI ROI, and [−2.70%,2.87%] for single‐voxel MRS. Linear regression between MRI and MRS indicated that the MRI method is highly accurate. Sensitivity and specificity for detection of steatosis using averaged MRI ROI were 100% and 94%, respectively. The relationship between hepatic fat‐fraction and body mass index was examined.Conclusion: Fat‐fraction measured with T1‐independent T‐corrected MRI and multi‐peak spectral modeling of fat is a highly precise and accurate method of quantifying hepatic steatosis. J. Magn. Reson. Imaging 2011;33:873–881.